Literature DB >> 19779221

A feasibility study of markerless fluoroscopic gating for lung cancer radiotherapy using 4DCT templates.

Ruijiang Li1, John H Lewis, Laura I Cerviño, Steve B Jiang.   

Abstract

A major difficulty in conformal lung cancer radiotherapy is respiratory organ motion, which may cause clinically significant targeting errors. Respiratory-gated radiotherapy allows for more precise delivery of prescribed radiation dose to the tumor, while minimizing normal tissue complications. Gating based on external surrogates is limited by its lack of accuracy, while gating based on implanted fiducial markers is limited primarily by the risk of pneumothorax due to marker implantation. Techniques for fluoroscopic gating without implanted fiducial markers (markerless gating) have been developed. These techniques usually require a training fluoroscopic image dataset with marked tumor positions in the images, which limits their clinical implementation. To remove this requirement, this study presents a markerless fluoroscopic gating algorithm based on 4DCT templates. To generate gating signals, we explored the application of three similarity measures or scores between fluoroscopic images and the reference 4DCT template: un-normalized cross-correlation (CC), normalized cross-correlation (NCC) and normalized mutual information (NMI), as well as average intensity (AI) of the region of interest (ROI) in the fluoroscopic images. Performance was evaluated using fluoroscopic and 4DCT data from three lung cancer patients. On average, gating based on CC achieves the highest treatment accuracy given the same efficiency, with a high target coverage (average between 91.9% and 98.6%) for a wide range of nominal duty cycles (20-50%). AI works well for two patients out of three, but failed for the third patient due to interference from the heart. Gating based on NCC and NMI usually failed below 50% nominal duty cycle. Based on this preliminary study with three patients, we found that the proposed CC-based gating algorithm can generate accurate and robust gating signals when using 4DCT reference template. However, this observation is based on results obtained from a very limited dataset, and further investigation on a larger patient population has to be done before its clinical implementation.

Entities:  

Mesh:

Year:  2009        PMID: 19779221     DOI: 10.1088/0031-9155/54/20/N03

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

1.  Use of dMLC for implementation of dynamic respiratory-gated radiation therapy.

Authors:  Eric W Pepin; Huanmei Wu; Hiroki Shirato
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

2.  Dynamic gating window for compensation of baseline shift in respiratory-gated radiation therapy.

Authors:  Eric W Pepin; Huanmei Wu; Hiroki Shirato
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

3.  Nonisocentric treatment strategy for breast radiation therapy: a proof of concept study.

Authors:  Ruijiang Li; Lei Xing; Kathleen C Horst; Karl Bush
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-03-15       Impact factor: 7.038

4.  Imaged-guided liver stereotactic body radiotherapy using VMAT and real-time adaptive tumor gating. Concerns about technique and preliminary clinical results.

Authors:  Carmen Llacer-Moscardo; Olivier Riou; David Azria; Ludovic Bedos; Norbert Ailleres; Francois Quenet; Philippe Rouanet; Marc Ychou; Pascal Fenoglietto
Journal:  Rep Pract Oncol Radiother       Date:  2016-09-05

5.  Intrafraction verification of gated RapidArc by using beam-level kilovoltage X-ray images.

Authors:  Ruijiang Li; Edward Mok; Daniel T Chang; Megan Daly; Billy W Loo; Maximilian Diehn; Quynh-Thu Le; Albert Koong; Lei Xing
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-05-02       Impact factor: 7.038

6.  Robust fluoroscopic tracking of fiducial markers: exploiting the spatial constraints.

Authors:  Rui Li; Gregory Sharp
Journal:  Phys Med Biol       Date:  2013-02-26       Impact factor: 3.609

7.  Automatic assessment of average diaphragm motion trajectory from 4DCT images through machine learning.

Authors:  Guang Li; Jie Wei; Hailiang Huang; Carl Philipp Gaebler; Amy Yuan; Joseph O Deasy
Journal:  Biomed Phys Eng Express       Date:  2015-12-29

8.  Real-time markerless tumour tracking with patient-specific deep learning using a personalised data generation strategy: proof of concept by phantom study.

Authors:  Wataru Takahashi; Shota Oshikawa; Shinichiro Mori
Journal:  Br J Radiol       Date:  2020-02-28       Impact factor: 3.039

9.  An algorithm to extract three-dimensional motion by marker tracking in the kV projections from an on-board imager: four-dimensional cone-beam CT and tumor tracking implications.

Authors:  Imad Ali; Nesreen Alsbou; Terence Herman; Salahuddin Ahmad
Journal:  J Appl Clin Med Phys       Date:  2011-02-01       Impact factor: 2.102

10.  Quantitative assessment by measurement and modeling of mobile target elongation in cone-beam computed tomographic imaging.

Authors:  Imad Ali; Nesreen Alsbou; Ozer Algan; Terence Herman; Salahuddin Ahmad
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.