Literature DB >> 19775885

A novel interdigitated capacitor based biosensor for detection of cardiovascular risk marker.

Anjum Quershi1, Yasar Gurbuz, Weng P Kang, Jimmy L Davidson.   

Abstract

C-reactive protein (CRP) is a potential biomarker whose elevated levels in humans determine cardiovascular disease risk and inflammation. In this study, we have developed a novel capacitive biosensor for detection of CRP-antigen using capacitor with interdigitated gold (GID) electrodes on nanocrystalline diamond (NCD) surface. The NCD surface served as a dielectric layer between the gold electrodes. GID-surface was functionalized by antibodies and the immobilization was confirmed by Fourier transform spectroscopy (FT-IR) and contact angle measurements. The CRP-antigen detection was performed by capacitive/dielectric-constant measurements. The relaxation time and polarizability constants were estimated using Cole-Cole model. Our results showed that the relaxation time constant (tau) of only CRP-antibody was within 10(-16)-10(-13)s, which was increased to 10(-11)s after the incubation with CRP-antigen, suggesting that the CRP-antigen was captured by the antibodies on GID-surface. In addition, polarizability constant (m) of CRP was also increased upon incubation with increasing concentration of CRP-antigen. Our results showed that the response of GID-NCD-based capacitive biosensor for CRP-antigen was dependent on both concentration (25-800ng/ml) as well as frequency (50-350MHz). Furthermore, using optimized conditions, the GID-NCD based capacitive biosensor developed in this study can potentially be used for detection of elevated levels of protein risk markers in suspected subjects for early diagnosis of disease.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19775885     DOI: 10.1016/j.bios.2009.08.043

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

Review 1.  Biosensors for hepatitis B virus detection.

Authors:  Chun-Yan Yao; Wei-Ling Fu
Journal:  World J Gastroenterol       Date:  2014-09-21       Impact factor: 5.742

Review 2.  Rapid and quantitative detection of hepatitis B virus.

Authors:  Yue-Ping Liu; Chun-Yan Yao
Journal:  World J Gastroenterol       Date:  2015-11-14       Impact factor: 5.742

3.  A High Sensitivity IDC-Electronic Tongue Using Dielectric/Sensing Membranes with Solvatochromic Dyes.

Authors:  Md Rajibur Rahaman Khan; Alireza Khalilian; Shin-Won Kang
Journal:  Sensors (Basel)       Date:  2016-05-10       Impact factor: 3.576

4.  Oriented Antibody Covalent Immobilization for Label-Free Impedimetric Detection of C-Reactive Protein via Direct and Sandwich Immunoassays.

Authors:  Abiola Adesina; Philani Mashazi
Journal:  Front Chem       Date:  2021-06-02       Impact factor: 5.221

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.