Literature DB >> 19770708

Peripheral endothelial cell damage after trephination of donor tissue.

Mark A Terry1, Hisham A Saad, Neda Shamie, Anand K Shah.   

Abstract

PURPOSE: To evaluate and quantify the degree and pattern of donor endothelial cell damage, which occurs with mechanical trephination of donor corneal tissue.
METHOD: Twenty donor corneal-scleral tissues were used for these paired experiments. The tissues were randomized for trephination with 10 tissues trephinated by an 8.0-mm-diameter Barron trephine (Katena, Denville, NJ), and 10 tissues trephinated with an 8.0-mm-diameter UltraFit Coronet trephine (distributed by Angiotech, British Columbia, Canada) by the same investigator. Trephinated corneal buttons were then stained with vital dye stain, and the endothelial layer image captured with digital photography. The images were then analyzed by digital planimetry, and the pattern and quantity of endothelial damage was determined by an investigator who was masked to the specific trephine used for the individual tissue.
RESULTS: Trephination created a pattern of circular damage at the edge of the donor button in every case with no break in continuity of the circle, but some portions of the circle were wider than others. Occasional, scattered, peripheral small areas also displayed damage, but no significant striae, stretch, or other central damage was noted in any donor. The mean percent damage in the series was 6.35% +/- 0.90% (range: 4.33%-7.78%). The UltraFit Coronet trephinations averaged damage of 5.64% +/- 0.85% (range: 4.33%-6.69%), and the Barron trephinations averaged damage of 6.50% +/- 0.95% (range: 4.92%-7.78%). Although 8 of 10 experimental pairs of trephinations demonstrated less peripheral endothelial damage with the UltraFit Coronet trephine, the mean damage between each group did not reach statistical significance in this small series. (P = 0.08)
CONCLUSIONS: Donor mechanical trephination of full-thickness corneal tissue creates relatively consistent amounts of peripheral edge damage and likely no central endothelial damage. There may exist differences in edge damage between different mechanical trephination systems, and a direct comparison to laser-created trephination is needed.

Entities:  

Mesh:

Year:  2009        PMID: 19770708     DOI: 10.1097/ICO.0b013e3181a87a28

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  8 in total

1.  Vulnerability of corneal endothelial cells to mechanical trauma from indentation forces assessed using contact mechanics and fluorescence microscopy.

Authors:  Manuel A Ramirez-Garcia; Yousuf M Khalifa; Mark R Buckley
Journal:  Exp Eye Res       Date:  2018-06-05       Impact factor: 3.467

Review 2.  Graft survival and endothelial outcomes in the new era of endothelial keratoplasty.

Authors:  Sanjay V Patel
Journal:  Exp Eye Res       Date:  2011-06-15       Impact factor: 3.467

3.  Analysis of posterior donor corneal parameters 1 year after Descemet stripping automated endothelial keratoplasty (DSAEK) triple procedure.

Authors:  Marco Lombardo; Mark A Terry; Giuseppe Lombardo; David D Boozer; Sebastiano Serrao; Pietro Ducoli
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-01-29       Impact factor: 3.117

Review 4.  Descemet's Stripping Automated Endothelial Keratoplasty Tissue Insertion Devices.

Authors:  Salman Nasir Khan; Panos S Shiakolas; Venkateswara Vinod Mootha
Journal:  J Ophthalmic Vis Res       Date:  2015 Oct-Dec

5.  Eye bank prepared versus surgeon cut endothelial graft tissue for Descemet membrane endothelial keratoplasty: An observational study.

Authors:  Marie Regnier; Céline Auxenfans; Delphine Maucort-Boulch; Anne-Sophie Marty; Odile Damour; Carole Burillon; Viridiana Kocaba
Journal:  Medicine (Baltimore)       Date:  2017-05       Impact factor: 1.889

Review 6.  Lamellar keratoplasty techniques.

Authors:  Nadisha P Singh; Dalia G Said; Harminder Singh Dua
Journal:  Indian J Ophthalmol       Date:  2018-09       Impact factor: 1.848

7.  Global cell-by-cell evaluation of endothelial viability after two methods of graft preparation in Descemet membrane endothelial keratoplasty.

Authors:  Maninder Bhogal; Maria S Balda; Karl Matter; Bruce D Allan
Journal:  Br J Ophthalmol       Date:  2016-01-06       Impact factor: 4.638

8.  Real-time assessment of corneal endothelial cell damage following graft preparation and donor insertion for DMEK.

Authors:  Maninder Bhogal; Chan N Lwin; Xin-Yi Seah; Elavazhagan Murugan; Khadijah Adnan; Shu-Jun Lin; Gary Peh; Jodhbir S Mehta
Journal:  PLoS One       Date:  2017-10-04       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.