Literature DB >> 19767479

Comparison of point-of-use technologies for emergency disinfection of sewage-contaminated drinking water.

S Devin McLennan1, Lauren A Peterson, Joan B Rose.   

Abstract

Four point-of-use disinfection technologies for treating sewage-contaminated well water were compared. Three systems, based on flocculant-disinfectant packets and N-halamine chlorine and bromine contact disinfectants, provided a range of 4.0 to >6.6 log(10) reductions (LR) of naturally occurring fecal indicator and heterotrophic bacteria and a range of 0.9 to >1.9 LR of coliphage.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19767479      PMCID: PMC2786525          DOI: 10.1128/AEM.00968-09

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  10 in total

1.  Household water treatment using sodium dichloroisocyanurate (NaDCC) tablets: a randomized, controlled trial to assess microbiological effectiveness in Bangladesh.

Authors:  Thomas Clasen; Tanveer F Saeed; Sophie Boisson; Paul Edmondson; Oleg Shipin
Journal:  Am J Trop Med Hyg       Date:  2007-01       Impact factor: 2.345

2.  Combining drinking water treatment and hand washing for diarrhoea prevention, a cluster randomised controlled trial.

Authors:  Stephen P Luby; Mubina Agboatwalla; John Painter; Arshad Altaf; Ward Billhimer; Bruce Keswick; Robert M Hoekstra
Journal:  Trop Med Int Health       Date:  2006-04       Impact factor: 2.622

3.  Point of use household drinking water filtration: A practical, effective solution for providing sustained access to safe drinking water in the developing world.

Authors:  Mark D Sobsey; Christine E Stauber; Lisa M Casanova; Joseph M Brown; Mark A Elliott
Journal:  Environ Sci Technol       Date:  2008-06-15       Impact factor: 9.028

4.  Membrane filter enumeration method for Clostridium perfringens.

Authors:  J W Bisson; V J Cabelli
Journal:  Appl Environ Microbiol       Date:  1979-01       Impact factor: 4.792

Review 5.  Sodium dichloroisocyanurate (NaDCC) tablets as an alternative to sodium hypochlorite for the routine treatment of drinking water at the household level.

Authors:  Thomas Clasen; Paul Edmondson
Journal:  Int J Hyg Environ Health       Date:  2006-01-04       Impact factor: 5.840

6.  Point-of-use water treatment and diarrhoea reduction in the emergency context: an effectiveness trial in Liberia.

Authors:  Shannon Doocy; Gilbert Burnham
Journal:  Trop Med Int Health       Date:  2006-10       Impact factor: 2.622

7.  Evaluation of a new disinfection approach: efficacy of chlorine and bromine halogenated contact disinfection for reduction of viruses and microcystin toxin.

Authors:  Angela D Coulliette; Lauren A Peterson; Joshua A W Mosberg; Joan B Rose
Journal:  Am J Trop Med Hyg       Date:  2010-02       Impact factor: 2.345

8.  Evaluation of a new water treatment for point-of-use household applications to remove microorganisms and arsenic from drinking water.

Authors:  Philip F Souter; Graeme D Cruickshank; Melanie Z Tankerville; Bruce H Keswick; Brian D Ellis; Don E Langworthy; Kathy A Metz; Martin R Appleby; Nicola Hamilton; Amanda L Jones; John D Perry
Journal:  J Water Health       Date:  2003-06       Impact factor: 1.744

9.  Effect of point-of-use disinfection, flocculation and combined flocculation-disinfection on drinking water quality in western Kenya.

Authors:  J A Crump; G O Okoth; L Slutsker; D O Ogaja; B H Keswick; S P Luby
Journal:  J Appl Microbiol       Date:  2004       Impact factor: 3.772

10.  A randomized controlled trial of household-based flocculant-disinfectant drinking water treatment for diarrhea prevention in rural Guatemala.

Authors:  Megan E Reller; Carlos E Mendoza; M Beatriz Lopez; Maricruz Alvarez; Robert M Hoekstra; Christy A Olson; Kathleen G Baier; Bruce H Keswick; Stephen P Luby
Journal:  Am J Trop Med Hyg       Date:  2003-10       Impact factor: 2.345

  10 in total
  2 in total

1.  Effects of temperature and pH on reduction of bacteria in a point-of-use drinking water treatment product for emergency relief.

Authors:  Jean-Thomas Marois-Fiset; Anne Carabin; Audrey Lavoie; Caetano C Dorea
Journal:  Appl Environ Microbiol       Date:  2013-01-18       Impact factor: 4.792

2.  Identification of viral pathogen diversity in sewage sludge by metagenome analysis.

Authors:  Kyle Bibby; Jordan Peccia
Journal:  Environ Sci Technol       Date:  2013-02-08       Impact factor: 9.028

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.