Literature DB >> 19763760

Effect of higher order aberrations on contrast sensitivity function in myopic eyes.

Sepehr Feizi1, Farid Karimian.   

Abstract

PURPOSE: To evaluate the relation between higher order aberrations (HOAs) and contrast sensitivity function (CSF) in a population with myopia.
METHODS: In this case series, HOAs were measured in 70 myopic eyes over a 6-mm pupil. Contrast sensitivity was also measured. From the contrast sensitivity data, the area under the log contrast sensitivity function (AULCSF) was calculated. Pupil diameter was measured under photopic conditions.
RESULTS: Seventy right eyes of 70 myopic subjects with a mean age of 26.6 +/- 5.7 years were studied. The mean spherical equivalent and refractive astigmatism were -4.97 +/- 1.6 D and 0.93 +/- 0.5 D, respectively. AULCSF was significantly but negatively correlated with the cycloplegic spherical equivalent (r (2) = 0.57, P = 0.02), the root mean square (RMS) of total HOAs (r (2) = 0.065, P = 0.03), the RMS of fourth-order aberrations (r (2) = 0.089, P = 0.015), and the RMS of the spherical aberration (r (2) = 0.037, P = 0.004). AULCSF did not have any significant association with age, photopic pupil diameter, refractive astigmatism, or the RMS of the coma aberration.
CONCLUSION: Spherical and fourth-order aberrations significantly affect CSF in myopic eyes. However, the effect of myopia on CSF cannot be attributed only to HOAs. Other factors such as neural elements in the visual pathway should be taken into account.

Entities:  

Mesh:

Year:  2009        PMID: 19763760     DOI: 10.1007/s10384-009-0677-4

Source DB:  PubMed          Journal:  Jpn J Ophthalmol        ISSN: 0021-5155            Impact factor:   2.447


  42 in total

1.  Age-related changes in monochromatic wave aberrations of the human eye.

Authors:  J S McLellan; S Marcos; S A Burns
Journal:  Invest Ophthalmol Vis Sci       Date:  2001-05       Impact factor: 4.799

Review 2.  Wavefront guided ablation.

Authors:  S M MacRae; D R Williams
Journal:  Am J Ophthalmol       Date:  2001-12       Impact factor: 5.258

3.  Comparison of ocular higher-order aberrations and visual performance between photorefractive keratectomy and laser in situ keratomileusis for myopia.

Authors:  Sayuri Ninomiya; Naoyuki Maeda; Teruhito Kuroda; Takashi Fujikado; Yasuo Tano
Journal:  Semin Ophthalmol       Date:  2003-03       Impact factor: 1.975

4.  Scaling Zernike expansion coefficients to different pupil sizes.

Authors:  Jim Schwiegerling
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2002-10       Impact factor: 2.129

5.  [Long-term effects of iterative diving on visual field, color vision and contrast sensitivity in professional divers].

Authors:  R Macarez; Y Dordain; M Hugon; J-L Kovalski; B Guigon; S Bazin; F May; J Colin
Journal:  J Fr Ophtalmol       Date:  2005-10       Impact factor: 0.818

6.  Visual performance after photorefractive keratectomy. A prospective study.

Authors:  W Verdon; M Bullimore; R K Maloney
Journal:  Arch Ophthalmol       Date:  1996-12

7.  Laser in situ keratomileusis to correct high myopia.

Authors:  J J Pérez-Santonja; J Bellot; P Claramonte; M M Ismail; J L Alió
Journal:  J Cataract Refract Surg       Date:  1997-04       Impact factor: 3.351

8.  Letter contrast sensitivity changes in early diabetic retinopathy.

Authors:  Efty P Stavrou; Joanne M Wood
Journal:  Clin Exp Optom       Date:  2003-05       Impact factor: 2.742

9.  Visual acuity and contrast sensitivity in patients with neovascular age-related macular degeneration. Results from the Radiation Therapy for Age-Related Macular Degeneration (RAD-) Study.

Authors:  Caren Bellmann; Kristina Unnebrink; Gary S Rubin; Daniel Miller; Frank G Holz
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-09-06       Impact factor: 3.117

10.  Prospective study of photorefractive keratectomy for myopia using the VISX StarS2 excimer laser system.

Authors:  Julian Stevens; Marco Giubilei; Linda Ficker; Paul Rosen
Journal:  J Refract Surg       Date:  2002 Sep-Oct       Impact factor: 3.573

View more
  5 in total

1.  Effect of higher-order aberrations and intraocular scatter on contrast sensitivity measured with a single instrument.

Authors:  Junlei Zhao; Fei Xiao; Haoxin Zhao; Yun Dai; Yudong Zhang
Journal:  Biomed Opt Express       Date:  2017-03-09       Impact factor: 3.732

Review 2.  Clinical application of accommodating intraocular lens.

Authors:  You-Ling Liang; Song-Bai Jia
Journal:  Int J Ophthalmol       Date:  2018-06-18       Impact factor: 1.779

3.  Effects of higher-order aberrations on contrast sensitivity in normal eyes of a large myopic population.

Authors:  Peng-Fei Zhao; Shi-Ming Li; Jing Lu; Hong-Min Song; Jing Zhang; Yue-Hua Zhou; Ning-Li Wang
Journal:  Int J Ophthalmol       Date:  2017-09-18       Impact factor: 1.779

4.  Relationship between higher-order aberrations and myopia progression in schoolchildren: a retrospective study.

Authors:  Ning Zhang; Xu-Bo Yang; Wen-Qiu Zhang; Long-Qian Liu; Guang-Jing Dong; Tao-Wen Chen; Meng Liao; Xuan Liao
Journal:  Int J Ophthalmol       Date:  2013-06-18       Impact factor: 1.779

5.  Factors influencing contrast sensitivity function in myopic eyes.

Authors:  Kazutaka Kamiya; Kimiya Shimizu; Ayaka Iijima; Hidenaga Kobashi
Journal:  PLoS One       Date:  2014-11-17       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.