Literature DB >> 19759087

A review of radiology staff doses and dose monitoring requirements.

C J Martin1.   

Abstract

Studies of radiation doses received during X-ray procedures by radiology, cardiology and other clinical staff have been reviewed. Data for effective dose (E), and doses to the eyes, thyroid, hands and legs have been analysed. These data have been supplemented with local measurements to determine the most exposed part of the hand for monitoring purposes. There are ranges of 60-100 in doses to individual tissues reported in the literature for similar procedures at different centres. While ranges in the doses per unit dose-area product (DAP) are between 10 and 25, large variations in dose result from differences in the sensitivity of the X-ray equipment, the type of procedure and the operator technique, but protection factors are important in maintaining dose levels as low as possible. The influence of shielding devices is significant for determining the dose to the eyes and thyroid, and the position of the operator, which depends on the procedure, is the most significant factor determining doses to the hands. A second body dosemeter worn at the level of the collar is recommended for operators with high workloads for use in assessment of effective dose and the dose to the eye. It is proposed that the third quartile values from the distributions of dose per unit DAP identified in the review might be employed in predicting the orders of magnitude of doses to the eye, thyroid and hands, based on interventional operator workloads. Such dose estimates could be employed in risk assessments when reviewing protection and monitoring requirements. A dosemeter worn on the little finger of the hand nearest to the X-ray tube is recommended for monitoring the hand.

Entities:  

Mesh:

Year:  2009        PMID: 19759087     DOI: 10.1093/rpd/ncp168

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  11 in total

1.  The impact of endoscopic retrograde cholangiopancreatography education on radiation exposure to experienced endoscopist: 'trainee effect'.

Authors:  Erkin Oztas; Erkan Parlak; Fahrettin Kucukay; Mehmet Arhan; Ulku Daglı; Digdem Ozer Etik; Fatih Oguz Onder; Tulay Olcer; Nurgul Sasmaz
Journal:  Dig Dis Sci       Date:  2012-05       Impact factor: 3.199

Review 2.  Personal dosimetry for interventional operators: when and how should monitoring be done?

Authors:  C J Martin
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

3.  Academic training in radiation safety awareness and practice among Iranian residents/fellows.

Authors:  Morteza Safi; Hossein Aerab-Sheibani; Mohammad Hassan Namazi; Hossein Vakili; Habibollah Saadat
Journal:  Heart Asia       Date:  2014-09-09

4.  Preclinical feasibility of a technology framework for MRI-guided iliac angioplasty.

Authors:  Martin A Rube; Fabiola Fernandez-Gutierrez; Benjamin F Cox; Andrew B Holbrook; J Graeme Houston; Richard D White; Helen McLeod; Mahsa Fatahi; Andreas Melzer
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-08-08       Impact factor: 2.924

5.  Radiation-induced noncancer risks in interventional cardiology: optimisation of procedures and staff and patient dose reduction.

Authors:  Zhonghua Sun; Aini AbAziz; Ahmad Khairuddin Md Yusof
Journal:  Biomed Res Int       Date:  2013-08-20       Impact factor: 3.411

6.  Real-time, ray casting-based scatter dose estimation for c-arm x-ray system.

Authors:  Zaid Alnewaini; Eric Langer; Philipp Schaber; Matthias David; Dominik Kretz; Volker Steil; Jürgen Hesser
Journal:  J Appl Clin Med Phys       Date:  2017-01-24       Impact factor: 2.102

7.  Evaluation of the current status of the eye lens radiation exposure in an Interventional Radiology department.

Authors:  Mariagabriella Pugliese; Antonia Amatiello; Marco Correra; Vincenzo Stoia; Vincenzo Cerciello; Vincenzo Roca; Filomena Loffredo; Francesco Fiore; Giuseppe La Verde
Journal:  Med Lav       Date:  2018-12-20       Impact factor: 1.275

8.  Surgeons' exposure to radiation in single- and multi-level minimally invasive transforaminal lumbar interbody fusion; a prospective study.

Authors:  Haruki Funao; Ken Ishii; Suketaka Momoshima; Akio Iwanami; Naobumi Hosogane; Kota Watanabe; Masaya Nakamura; Yoshiaki Toyama; Morio Matsumoto
Journal:  PLoS One       Date:  2014-04-15       Impact factor: 3.240

9.  Operator Radiation Exposure in Cone-Beam Computed Tomography Guidance.

Authors:  S J Braak; Mjl Strijen van; E Meijer; Jpm Heesewijk van; WPThM Mali
Journal:  J Belg Soc Radiol       Date:  2016-02-26       Impact factor: 1.894

10.  Radiation Protection in Interventional Radiology/Cardiology-Is State-of-the-Art Equipment Used?

Authors:  Christiane Behr-Meenen; Heiner von Boetticher; Jan Felix Kersten; Albert Nienhaus
Journal:  Int J Environ Res Public Health       Date:  2021-12-13       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.