Bioreactance: a new tool for cardiac output and thoracic fluid content monitoring during hemodialysis.

Niloufar Kossari1, Gilles Hufnagel, Pierre Squara.   

Abstract

Outpatient hemodialysis therapy (HD) can be associated with hemodynamic compromise. Bioreactance has recently been shown to provide accurate, noninvasive, continuous, measurements of cardiac output (CO) and thoracic impedance (Zo) from which thoracic fluid content (TFC) can be derived assuming TFC=1000/Zo. This study was designed to evaluate the changes in TFC in comparison with the traditional indices of fluid removal (FR) and to understand the trends in CO changes in HD patients. Minute-by-minute changes in TFC and CO were prospectively collected using the bioreactance system (NICOM) in HD patients of a single unit. Changes in body weight (DeltaW), hematocrit (DeltaHct), and amount of FR were also measured. Twenty-five patients (age 77 +/- 11 years) were included. The TFC decreased in all patients by an average of 5.4 +/- 7.9 kohm(-1), weight decreased by 1.48 +/- 0.98 kg, and FR averaged 2.07 +/- 1.93 L over a 3- to 4-hour HD session. There were good correlations between DeltaTFC and DeltaW (R=0.80, P<0.0001) and FR (R=0.85, P<0.0001). DeltaHct (4.13 +/- 3.42%) was poorly correlated with DeltaTFC (R=0.35, P=0.12) and FR (R=0.40, P=0.07). The regression line between FR and TFC yielded FR=1.0024-0.1985TFC; thus, a 1 kohm(-1) change of Zo correlates with an approximately 200 mL change in total body water. The change in CO (-0.52 +/- 0.49 L/min m(2)) during HD did not correlate with FR (R=0.15, P=NS). Changes in TFC represented the monitored variable most closely related to FR. CO remained fairly constant in this stable patient cohort. Further studies in high-risk patients are warranted to understand whether TFC and CO monitoring can improve HD session management.

Entities:  

Mesh:

Year:  2009        PMID: 19758300     DOI: 10.1111/j.1542-4758.2009.00386.x

Source DB:  PubMed          Journal:  Hemodial Int        ISSN: 1492-7535            Impact factor:   1.812


  13 in total

Review 1.  Cardiac output monitoring devices: an analytic review.

Authors:  Jahan Porhomayon; Ali El-Solh; Peter Papadakos; Nader Djalal Nader
Journal:  Intern Emerg Med       Date:  2011-12-07       Impact factor: 3.397

2.  The effect of head up tilting on bioreactance cardiac output and stroke volume readings using suprasternal transcutaneous Doppler as a control in healthy young adults.

Authors:  Jie Zhang; Lester A H Critchley; Daniel C W Lee; Kim S Khaw; Shara W Y Lee
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

3.  Applications of minimally invasive cardiac output monitors.

Authors:  Jahan Porhomayon; Gino Zadeii; Samuel Congello; Nader D Nader
Journal:  Int J Emerg Med       Date:  2012-04-24

4.  Assessing Extracellular Volume in Hemodialysis Patients Using Intradialytic Blood Pressure Slopes.

Authors:  Hao Liu; Rong Lu; Shani Shastri; Mark Sonderman; Peter Noel Van Buren
Journal:  Nephron       Date:  2018-02-13       Impact factor: 2.847

5.  Lung water assessment: from gravimetry to wearables.

Authors:  Frederic Michard
Journal:  J Clin Monit Comput       Date:  2018-05-11       Impact factor: 2.502

6.  Reduced thoracic fluid content in early-stage primary biliary cirrhosis that associates with impaired cardiac inotropy.

Authors:  Pawel Zalewski; David Jones; Ieuan Lewis; James Frith; Julia L Newton
Journal:  Am J Physiol Gastrointest Liver Physiol       Date:  2013-07-18       Impact factor: 4.052

7.  Bioreactance Is Not Interchangeable with Thermodilution for Measuring Cardiac Output during Adult Liver Transplantation.

Authors:  Sangbin Han; Jong Hwan Lee; Gaabsoo Kim; Justin Sangwook Ko; Soo Joo Choi; Ji Hae Kwon; Burn Young Heo; Mi Sook Gwak
Journal:  PLoS One       Date:  2015-05-27       Impact factor: 3.240

8.  Design and methods of CYCLE-HD: improving cardiovascular health in patients with end stage renal disease using a structured programme of exercise: a randomised control trial.

Authors:  M P M Graham-Brown; D S March; D R Churchward; H M L Young; M Dungey; S Lloyd; N J Brunskill; A C Smith; G P McCann; J O Burton
Journal:  BMC Nephrol       Date:  2016-07-08       Impact factor: 2.388

9.  Extracellular Volume Overload and Increased Vasoconstriction in Patients With Recurrent Intradialytic Hypertension.

Authors:  Peter Noel Van Buren; Yunyun Zhou; Javier A Neyra; Guanghua Xiao; Wanpen Vongpatanasin; Jula Inrig; Robert Toto
Journal:  Kidney Blood Press Res       Date:  2016-11-11       Impact factor: 2.687

Review 10.  Clinical review: Does it matter which hemodynamic monitoring system is used?

Authors:  Davinder Ramsingh; Brenton Alexander; Maxime Cannesson
Journal:  Crit Care       Date:  2013-03-05       Impact factor: 9.097