Literature DB >> 19756464

[Color duplex sonography of extracranial brain-supplying arteries].

G Schulte-Altedorneburg1, D-A Clevert.   

Abstract

Ultrasound examination of extracranial blood-supplying arteries allows the simultaneous acquisition of morphologic and hemodynamic information with high spatial and temporal resolution. For detection and quantification of stenoses in the carotid and vertebral arteries, an intrastenotic peak systolic velocity of more than 120 cm/s is the threshold value for a diameter reduction of >50%. In addition there are further direct and indirect stenosis parameters (intrastenotic and poststenotic circulation disturbance, increased pulsatility in the prestenotic common carotid artery, intracranial or extracranial collateral pathways) which together with diameter and area reduction in the B-scan, lead to a high reliability of color duplex sonography for stenoses of the internal carotid artery (ICA). Sonographic and patho-anatomic comparative studies have shown a high agreement (r >0.9) by using a battery of several ultrasound criteria. Following stenting of the ICA the blood flow velocity in the stent is generally increased so that a > or =70% in-stent restenosis is present in case of a peak systolic velocity of 300-450 cm/s. For the description of arteriosclerotic plaques in the B-scan, ultrasound terminology but not histological terms should be used to describe the internal, surface and motion structure of plaques as well as the sonic shadow formation.

Entities:  

Mesh:

Year:  2009        PMID: 19756464     DOI: 10.1007/s00117-009-1872-5

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  28 in total

1.  Accuracy of in vivo carotid B-mode ultrasound compared with pathological analysis: intima-media thickening, lumen diameter, and cross-sectional area.

Authors:  G Schulte-Altedorneburg; D W Droste; S Felszeghy; M Kellermann; V Popa; K Hegedüs; C Hegedüs; M Schmid; L Módis; E B Ringelstein; L Csiba
Journal:  Stroke       Date:  2001-07       Impact factor: 7.914

2.  Improved diagnosis of vascular dissection by ultrasound B-flow: a comparison with color-coded Doppler and power Doppler sonography.

Authors:  D-A Clevert; N Rupp; M Reiser; E M Jung
Journal:  Eur Radiol       Date:  2004-09-24       Impact factor: 5.315

Review 3.  Cervicocranial arterial dissections.

Authors:  Louis R Caplan; Valérie Biousse
Journal:  J Neuroophthalmol       Date:  2004-12       Impact factor: 3.042

Review 4.  Vertebrobasilar disease.

Authors:  Sean I Savitz; Louis R Caplan
Journal:  N Engl J Med       Date:  2005-06-23       Impact factor: 91.245

5.  Skepticism toward carotid ultrasonography. A virtue, an attitude, or fanaticism?

Authors:  E B Ringelstein
Journal:  Stroke       Date:  1995-10       Impact factor: 7.914

6.  High-grade stenoses of the internal carotid artery: comparison of high-resolution contrast enhanced 3D MRA, duplex sonography and power Doppler imaging.

Authors:  D-A Clevert; T Johnson; H Michaely; E M Jung; P M Flach; T I Strautz; D-A Clevert; M Reiser; S O Schoenberg
Journal:  Eur J Radiol       Date:  2006-08-21       Impact factor: 3.528

7.  Diagnostics and characterisation of preocclusive stenoses and occlusions of the internal carotid artery with B-flow.

Authors:  E M Jung; R Kubale; G Ritter; M T Gallegos; K-P Jungius; N Rupp; D-A Clevert
Journal:  Eur Radiol       Date:  2006-05-16       Impact factor: 5.315

8.  New England Medical Center Posterior Circulation registry.

Authors:  Louis R Caplan; Robert J Wityk; Thomas A Glass; Jorge Tapia; Ladislav Pazdera; Hui-Meng Chang; Phillip Teal; John F Dashe; Claudia J Chaves; Joan C Breen; Kostas Vemmos; Pierre Amarenco; Barbara Tettenborn; Megan Leary; Conrad Estol; L Dana Dewitt; Michael S Pessin
Journal:  Ann Neurol       Date:  2004-09       Impact factor: 10.422

9.  Detection of carotid artery stenosis by in vivo duplex ultrasound: correlation with planimetric measurements of the corresponding postmortem specimens.

Authors:  Gernot Schulte-Altedorneburg; Dirk W Droste; Szabolcs Felszeghy; László Csiba; Vasile Popa; Katalin Hegedüs; József Kollár; László Módis; E Bernd Ringelstein
Journal:  Stroke       Date:  2002-10       Impact factor: 7.914

10.  Ultrasound findings in spontaneous extracranial vertebral artery dissection.

Authors:  M Sturzenegger; H P Mattle; A Rivoir; F Rihs; C Schmid
Journal:  Stroke       Date:  1993-12       Impact factor: 7.914

View more
  3 in total

1.  [Contrast-enhanced ultrasound in animal models].

Authors:  P M Paprottka; P Zengel; M Ingrisch; C C Cyran; M Eichhorn; M F Reiser; K Nikolaou; D-A Clevert
Journal:  Radiologe       Date:  2011-06       Impact factor: 0.635

2.  [Contrast-enhanced ultrasound imaging of the carotid artery].

Authors:  D-A Clevert; A Helck; P M Paprottka; M F Reiser; E M Jung
Journal:  Radiologe       Date:  2011-06       Impact factor: 0.635

Review 3.  Diagnostic vascular ultrasonography with the help of color Doppler and contrast-enhanced ultrasonography.

Authors:  Johannes Rübenthaler; Maximilian Reiser; Dirk-André Clevert
Journal:  Ultrasonography       Date:  2016-08-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.