Literature DB >> 16920314

High-grade stenoses of the internal carotid artery: comparison of high-resolution contrast enhanced 3D MRA, duplex sonography and power Doppler imaging.

D-A Clevert1, T Johnson, H Michaely, E M Jung, P M Flach, T I Strautz, D-A Clevert1, M Reiser, S O Schoenberg.   

Abstract

PURPOSE: The objective of this study was to determine the agreement and diagnostic accuracy of high-resolution contrast enhanced magnetic resonance angiography (MRA) with integrated parallel acquisition techniques (iPAT), color coded duplex ultrasound (CCDS) and power Doppler ultrasound (PD) in the assessment of high-grade stenoses of the internal carotid artery (ICA).
METHODS: Forty-four patients with 52 known or suspected stenoses of the internal carotid artery (ICA) were included in this prospective study. High-resolution MRA scans with a spatial resolution of 0.9 mm x 0.7 mm x 0.9 mm were acquired with an iPAT acceleration factor of 2 on a 1.5T MR system (Sonata Maestro Class, Siemens Medical Solutions, Erlangen, Germany) with a head, neck and body coil. For the 3D-CE MRA a fast spoiled gradient echo sequence (FLASH) was used. To compensate for the inherent signal loss with parallel imaging, a 1M contrast agent (gadobutrol, Gadovist, Schering, Berlin, Germany) was used. Stenoses were quantified by two readers in consensus in cross-sectional area measurements and graded according to the NASCET criteria. Using color coded duplex ultrasound (CCDS) and power Doppler (PD; Logiq 9, GE), the stenoses were also graded by two readers in consensus according to the NASCET criteria from intra- and post-stenotic diameter measurements. The results of MRA, CCDS and PD were compared to intraoperative findings or to follow-up examinations.
RESULTS: High-resolution MRA allowed an excellent grading of vascular stenoses. In 70-90% degrees of stenosis there was an underestimation of the degree of stenosis in MRA as well as in CCDS. However, there was an overestimation of 90% stenoses in both MRA and CCDS. Pseudoocclusions with a lumen of less than one millimeter were occasionally rated as a complete occlusion in MRA.
CONCLUSION: A combination of MRA and duplex sonography seems reasonable for the accurate grading of stenoses and determination of distal stenoses downstream. However, the accuracy of duplex ultrasound depends on the examiner's experience.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16920314     DOI: 10.1016/j.ejrad.2006.07.012

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  12 in total

1.  Non-ECG-gated unenhanced MRA of the carotids: optimization and clinical feasibility.

Authors:  H Raoult; J Y Gauvrit; P Schmitt; V Le Couls; E Bannier
Journal:  Eur Radiol       Date:  2013-06-20       Impact factor: 5.315

2.  [Color duplex sonography of extracranial brain-supplying arteries].

Authors:  G Schulte-Altedorneburg; D-A Clevert
Journal:  Radiologe       Date:  2009-11       Impact factor: 0.635

3.  [Current developments in vascular ultrasound].

Authors:  A Horng; M Reiser; D-A Clevert
Journal:  Radiologe       Date:  2009-11       Impact factor: 0.635

4.  Magnetic resonance angiography of the carotid arteries: comparison of unenhanced and contrast enhanced techniques.

Authors:  Harald Kramer; Val M Runge; John N Morelli; Kenneth D Williams; L Gill Naul; Konstantin Nikolaou; Maximilian F Reiser; Bernd J Wintersperger
Journal:  Eur Radiol       Date:  2011-04-09       Impact factor: 5.315

5.  [Contrast-enhanced ultrasound imaging of the carotid artery].

Authors:  D-A Clevert; A Helck; P M Paprottka; M F Reiser; E M Jung
Journal:  Radiologe       Date:  2011-06       Impact factor: 0.635

6.  Systematic review of preoperative carotid duplex ultrasound compared with computed tomography carotid angiography for carotid endarterectomy.

Authors:  T Forjoe; M Asad Rahi
Journal:  Ann R Coll Surg Engl       Date:  2019-02-15       Impact factor: 1.891

Review 7.  Contrast-enhanced ultrasound of the carotid system: a review of the current literature.

Authors:  Vasileios Rafailidis; Afroditi Charitanti; Thomas Tegos; Evangelos Destanis; Ioannis Chryssogonidis
Journal:  J Ultrasound       Date:  2017-02-09

Review 8.  Duplex ultrasound for diagnosing symptomatic carotid stenosis in the extracranial segments.

Authors:  Nicolle Cassola; Jose Cc Baptista-Silva; Luis Cu Nakano; Carolina Dq Flumignan; Ricardo Sesso; Vladimir Vasconcelos; Nelson Carvas Junior; Ronald Lg Flumignan
Journal:  Cochrane Database Syst Rev       Date:  2022-07-11

9.  Visualization of coronary wall atherosclerosis in asymptomatic subjects and patients with coronary artery disease using magnetic resonance imaging.

Authors:  Suzanne C Gerretsen; M Eline Kooi; Alfons G Kessels; Simon Schalla; Marcus Katoh; Rob J van der Geest; Warren J Manning; Johannes Waltenberger; Jos M A van Engelshoven; Rene M Botnar; Tim Leiner
Journal:  PLoS One       Date:  2010-09-29       Impact factor: 3.240

10.  Functional assessment of high-grade ICA stenosis with duplex ultrasound and transcranial Doppler.

Authors:  Helene Zachrisson; Marita Fouladiun; Christian Blomstrand; Jan Holm; Reinhard Volkmann
Journal:  Clin Physiol Funct Imaging       Date:  2012-01-29       Impact factor: 2.273

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.