Literature DB >> 19756114

High-power wavelength-swept laser in Littman telescope-less polygon filter and dual-amplifier configuration for multichannel optical coherence tomography.

Michael K K Leung1, Adrian Mariampillai, Beau A Standish, Kenneth K C Lee, Nigel R Munce, I Alex Vitkin, Victor X D Yang.   

Abstract

We report a high-power wavelength-swept laser source for multichannel optical coherence tomography (OCT) imaging. Wavelength tuning is performed by a compact telescope-less polygon-based filter in Littman arrangement. High output power is achieved by incorporating two serial semiconductor optical amplifiers in the laser cavity in Fourier domain mode-locked configuration. The measured wavelength tuning range of the laser is 111 nm centered at 1329 nm, coherence length of 5.5 mm, and total average output power of 131 mW at 43 kHz sweeping rate. Multichannel simultaneous OCT imaging at an equivalent A-scan rate of 258 kHz is demonstrated.

Mesh:

Year:  2009        PMID: 19756114     DOI: 10.1364/OL.34.002814

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  6 in total

1.  Multi-beam OCT imaging based on an integrated, free-space interferometer.

Authors:  Yongjoo Kim; Norman Lippok; Benjamin J Vakoc
Journal:  Biomed Opt Express       Date:  2020-12-08       Impact factor: 3.732

Review 2.  High-speed OCT light sources and systems [Invited].

Authors:  Thomas Klein; Robert Huber
Journal:  Biomed Opt Express       Date:  2017-01-13       Impact factor: 3.732

3.  Three-dimensional anterior segment imaging in patients with type 1 Boston Keratoprosthesis with switchable full depth range swept source optical coherence tomography.

Authors:  Raju Poddar; Poddar Raju; Dennis E Cortés; John S Werner; Mark J Mannis; Robert J Zawadzki
Journal:  J Biomed Opt       Date:  2013-08       Impact factor: 3.170

4.  Coherence revival multiplexed, buffered swept source optical coherence tomography: 400 kHz imaging with a 100 kHz source.

Authors:  Derek Nankivil; Al-Hafeez Dhalla; Niklas Gahm; Kevin Shia; Sina Farsiu; Joseph A Izatt
Journal:  Opt Lett       Date:  2014-07-01       Impact factor: 3.776

5.  Corneal topography with high-speed swept source OCT in clinical examination.

Authors:  Karol Karnowski; Bartlomiej J Kaluzny; Maciej Szkulmowski; Michalina Gora; Maciej Wojtkowski
Journal:  Biomed Opt Express       Date:  2011-08-29       Impact factor: 3.732

6.  Multi-directional optical coherence tomography for retinal imaging.

Authors:  Andreas Wartak; Marco Augustin; Richard Haindl; Florian Beer; Matthias Salas; Marie Laslandes; Bernhard Baumann; Michael Pircher; Christoph K Hitzenberger
Journal:  Biomed Opt Express       Date:  2017-11-13       Impact factor: 3.732

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.