Literature DB >> 19754213

Dosimetric comparisons of three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and helical tomotherapy in whole abdominopelvic radiotherapy for gynecologic malignancy.

Yong Bae Kim1, Joo Ho Kim, Kyung Keun Jeong, Jinsil Seong, Chang Ok Suh, Gwi Eon Kim.   

Abstract

OBJECTIVES: The goal of this study was to dosimetrically compare 3-dimensional radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), and helical tomotherapy (TOMO) plans for whole abdominopelvic radiotherapy (WART) in patients with gynecologic cancer.
METHODS: Ten patients were selected for WART planning. Doses were prescribed to planning target volumes (PTVs) as the followings: 30 Gy to PTV-whole abdominopelvis (PTV-WA), 40 Gy to PTV-para-aortic lymph node (PTV-PALN), 44 Gy to PTV-pelvis, and 50 Gy to gross target volume (GTV) in 20 fractions. Dose to whole liver, both kidneys, and spinal cord were constrained below each tissue tolerance, and bone marrow (BM)-sparing technique was adopted in IMRT and TOMO. Dosimetric parameters and treatment times were compared among plans.
RESULTS: Calculated doses in TOMO came most closely to the prescribed dose for coverage of PTV-WA, PTV-PALN, PTV-pelvis, and GTV compared to 3DCRT, and IMRT. In normal organs, TOMO had significantly better dosimetric profiles compared to IMRT and 3DCRT. TOMO significantly reduced V(20Gy), and mean dose of whole liver, both kidneys, and spinal cord. The use of BM-sparing technique (BMS) did not impair coverage of target volume in IMRT and TOMO. While IMRT showed no differences of irradiated BM dose using BMS, TOMO with BMS reduced half V(20Gy) of BM compared to TOMO without BMS.
CONCLUSIONS: TOMO showed dosimetric superiority in target coverage, sparing BM, and other normal organs compared to 3DCRT and IMRT. Clinical experiences will be needed for evaluation of feasibility of WART using TOMO in patients with gynecologic cancer.

Entities:  

Mesh:

Year:  2009        PMID: 19754213     DOI: 10.1177/153303460900800507

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  4 in total

1.  Impact of different optimization strategies on the compatibility between planned and delivered doses during radiation therapy of cervical cancer.

Authors:  Agata Jodda; Tomasz Piotrowski; Marta Kruszyna-Mochalska; Julian Malicki
Journal:  Rep Pract Oncol Radiother       Date:  2020-04-12

2.  Risk stratification of abdominopelvic failure for FIGO stage III epithelial ovarian cancer patients: implications for adjuvant radiotherapy.

Authors:  Jee Suk Chang; Woong Sub Koom; Sang Wun Kim; Sunghoon Kim; Yong Bae Kim; Young Tae Kim; Gwi Eon Kim
Journal:  J Gynecol Oncol       Date:  2013-04-05       Impact factor: 4.401

3.  The air matters - sleeve air cavity as a marker guiding image-guided helical tomotherapy to target cervical cancer.

Authors:  Ya-Ting Jan; Chih-Long Chang; Hung-Chi Tai; Yu-Chuen Huang; Chia-Ling Liao; Yu-Jen Chen
Journal:  J Contemp Brachytherapy       Date:  2016-02-08

4.  Tomotherapy - a different way of dose delivery in radiotherapy.

Authors:  Tomasz Piotrowski; Małgorzata Skórska; Agata Jodda; Adam Ryczkowski; Joanna Kaźmierska; Krystyna Adamska; Aldona Karczewska-Dzionk; Małgorzata Zmijewska-Tomczak; Hanna Włodarczyk
Journal:  Contemp Oncol (Pozn)       Date:  2012-02-29
  4 in total