Literature DB >> 19750180

Adaptive and Quality Quadrilateral/Hexahedral Meshing from Volumetric Data.

Yongjie Zhang1, Chandrajit Bajaj.   

Abstract

This paper describes an algorithm to extract adaptive and quality quadrilateral/hexahedral meshes directly from volumetric data. First, a bottom-up surface topology preserving octree-based algorithm is applied to select a starting octree level. Then the dual contouring method is used to extract a preliminary uniform quad/hex mesh, which is decomposed into finer quads/hexes adaptively without introducing any hanging nodes. The positions of all boundary vertices are recalculated to approximate the boundary surface more accurately. Mesh adaptivity can be controlled by a feature sensitive error function, the regions that users are interested in, or finite element calculation results. Finally, a relaxation based technique is deployed to improve mesh quality. Several demonstration examples are provided from a wide variety of application domains. Some extracted meshes have been extensively used in finite element simulations.

Entities:  

Year:  2006        PMID: 19750180      PMCID: PMC2740490          DOI: 10.1016/j.cma.2005.02.016

Source DB:  PubMed          Journal:  Comput Methods Appl Mech Eng        ISSN: 0045-7825            Impact factor:   6.756


  3 in total

1.  Continuum diffusion reaction rate calculations of wild-type and mutant mouse acetylcholinesterase: adaptive finite element analysis.

Authors:  Yuhua Song; Yongjie Zhang; Chandrajit L Bajaj; Nathan A Baker
Journal:  Biophys J       Date:  2004-09       Impact factor: 4.033

2.  Finite element solution of the steady-state Smoluchowski equation for rate constant calculations.

Authors:  Yuhua Song; Yongjie Zhang; Tongye Shen; Chandrajit L Bajaj; J Andrew McCammon; Nathan A Baker
Journal:  Biophys J       Date:  2004-04       Impact factor: 4.033

3.  3D Finite Element Meshing from Imaging Data.

Authors:  Yongjie Zhang; Chandrajit Bajaj; Bong-Soo Sohn
Journal:  Comput Methods Appl Mech Eng       Date:  2005-11-15       Impact factor: 6.756

  3 in total
  13 in total

1.  Modeling Cardiovascular Anatomy from Patient-Specific Imaging Data.

Authors:  Chandrajit Bajaj; Samrat Goswami
Journal:  Comput Methods Appl Sci       Date:  2009-01-01

2.  Influence of nonuniform geometry on nanoindentation of viral capsids.

Authors:  Melissa M Gibbons; William S Klug
Journal:  Biophys J       Date:  2008-07-11       Impact factor: 4.033

3.  Surface Smoothing and Quality Improvement of Quadrilateral/Hexahedral Meshes with Geometric Flow.

Authors:  Yongjie Zhang; Chandrajit Bajaj; Guoliang Xu
Journal:  Commun Numer Methods Eng       Date:  2007-11-20

4.  All-Hex Meshing of Multiple-Region Domains without Cleanup.

Authors:  Muhammad A Awad; Ahmad A Rushdi; Misarah A Abbas; Scott A Mitchell; Ahmed H Mahmoud; Chandrajit L Bajaj; Mohamed S Ebeida
Journal:  Procedia Eng       Date:  2016

5.  Large-scale subject-specific cerebral arterial tree modeling using automated parametric mesh generation for blood flow simulation.

Authors:  Mahsa Ghaffari; Kevin Tangen; Ali Alaraj; Xinjian Du; Fady T Charbel; Andreas A Linninger
Journal:  Comput Biol Med       Date:  2017-10-24       Impact factor: 4.589

6.  An eFace-Template Method for Efficiently Generating Patient-Specific Anatomically-Detailed Facial Soft Tissue FE Models for Craniomaxillofacial Surgery Simulation.

Authors:  Xiaoyan Zhang; Zhen Tang; Michael A K Liebschner; Daeseung Kim; Shunyao Shen; Chien-Ming Chang; Peng Yuan; Guangming Zhang; Jaime Gateno; Xiaobo Zhou; Shao-Xiang Zhang; James J Xia
Journal:  Ann Biomed Eng       Date:  2015-10-13       Impact factor: 3.934

7.  Dynamic Data-Driven Finite Element Models for Laser Treatment of Cancer.

Authors:  J T Oden; K R Diller; C Bajaj; J C Browne; J Hazle; I Babuška; J Bass; L Biduat; L Demkowicz; A Elliott; Y Feng; D Fuentes; S Prudhomme; M N Rylander; R J Stafford; Y Zhang
Journal:  Numer Methods Partial Differ Equ       Date:  2007-04-26       Impact factor: 3.009

8.  Patient-Specific Vascular NURBS Modeling for Isogeometric Analysis of Blood Flow.

Authors:  Yongjie Zhang; Yuri Bazilevs; Samrat Goswami; Chandrajit L Bajaj; Thomas J R Hughes
Journal:  Comput Methods Appl Mech Eng       Date:  2007-05-15       Impact factor: 6.756

9.  A computer modeling tool for comparing novel ICD electrode orientations in children and adults.

Authors:  Matthew Jolley; Jeroen Stinstra; Steve Pieper; Rob Macleod; Dana H Brooks; Frank Cecchin; John K Triedman
Journal:  Heart Rhythm       Date:  2008-01-17       Impact factor: 6.343

10.  An eFTD-VP framework for efficiently generating patient-specific anatomically detailed facial soft tissue FE mesh for craniomaxillofacial surgery simulation.

Authors:  Xiaoyan Zhang; Daeseung Kim; Shunyao Shen; Peng Yuan; Siting Liu; Zhen Tang; Guangming Zhang; Xiaobo Zhou; Jaime Gateno; Michael A K Liebschner; James J Xia
Journal:  Biomech Model Mechanobiol       Date:  2017-10-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.