Literature DB >> 19746781

Quality assurance for clinical implementation of an electromagnetic tracking system.

Lakshmi Santanam1, Camille Noel, Twyla R Willoughby, Jacqueline Esthappan, Sasa Mutic, Eric E Klein, Daniel A Low, Parag J Parikh.   

Abstract

The Calypso Medical 4D localization system utilizes alternating current electromagnetics for accurate, real-time tumor tracking. A quality assurance program to clinically implement this system is described here. Testing of the continuous electromagnetic tracking system (Calypso Medical Technologies, Seattle, WA) was performed using an in-house developed four-dimensional stage and a quality assurance fixture containing three radiofrequency transponders at independently measured locations. The following tests were performed to validate the Calypso system: (a) Localization and tracking accuracy, (b) system reproducibility, (c) measurement of the latency of the tracking system, and (d) measurement of transmission through the Calypso table overlay and the electromagnetic array. The translational and rotational localization accuracies were found to be within 0.01 cm and 1.0 degree, respectively. The reproducibility was within 0.1 cm. The average system latency was measured to be within 303 ms. The attenuation by the Calypso overlay was measured to be 1.0% for both 6 and 18 MV photons. The attenuations by the Calypso array were measured to be 2% and 1.5% for 6 and 18 MV photons, respectively. For oblique angles, the transmission was measured to be 3% for 6 MV, while it was 2% for 18 MV photons. A quality assurance process has been developed for the clinical implementation of an electromagnetic tracking system in radiation therapy.

Entities:  

Mesh:

Year:  2009        PMID: 19746781     DOI: 10.1118/1.3158812

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Target tracking using DMLC for volumetric modulated arc therapy: a simulation study.

Authors:  Baozhou Sun; Dharanipathy Rangaraj; Lech Papiez; Swetha Oddiraju; Deshan Yang; H Harold Li
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

2.  Failure mode and effect analysis-based quality assurance for dynamic MLC tracking systems.

Authors:  Amit Sawant; Sonja Dieterich; Michelle Svatos; Paul Keall
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

3.  Determination of action thresholds for electromagnetic tracking system-guided hypofractionated prostate radiotherapy using volumetric modulated arc therapy.

Authors:  Pengpeng Zhang; Dennis Mah; Laura Happersett; Brett Cox; Margie Hunt; Gig Mageras
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

Review 4.  Stereotactic radiotherapy for early stage non-small cell lung cancer: current standards and ongoing research.

Authors:  Eugenia Vlaskou Badra; Michael Baumgartl; Silvia Fabiano; Aurélien Jongen; Matthias Guckenberger
Journal:  Transl Lung Cancer Res       Date:  2021-04

5.  Effects on the photon beam from an electromagnetic array used for patient localization and tumor tracking.

Authors:  Wei Zou; Ricardo Betancourt; Lingshu Yin; James Metz; Stephen Avery; Alireza Kassaee
Journal:  J Appl Clin Med Phys       Date:  2013-05-06       Impact factor: 2.102

Review 6.  Expanding the use of real-time electromagnetic tracking in radiation oncology.

Authors:  Amish P Shah; Patrick A Kupelian; Twyla R Willoughby; Sanford L Meeks
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

7.  Comparison between electromagnetic transponders and radiographic imaging for prostate localization: A pelvic phantom study with rotations and translations.

Authors:  Daniel G Hamilton; Dean P McKenzie; Anne E Perkins
Journal:  J Appl Clin Med Phys       Date:  2017-07-12       Impact factor: 2.102

8.  Commissioning and quality assurance of Calypso four-dimensional target localization system in linear accelerator facility.

Authors:  K R Muralidhar; Krishna Komanduri; Birendra Kumar Rout; K K D Ramesh
Journal:  J Med Phys       Date:  2013-07

9.  Real-time intrafraction prostate motion during linac based stereotactic radiotherapy with rectal displacement.

Authors:  Kimberley Legge; Doan Nguyen; Jin Aun Ng; Lee Wilton; Matthew Richardson; Jeremy Booth; Paul Keall; Darryl J O'Connor; Peter Greer; Jarad Martin
Journal:  J Appl Clin Med Phys       Date:  2017-09-27       Impact factor: 2.102

10.  Validation of the Calypso Surface Beacon Transponder.

Authors:  Maxwell Belanger; Ziad Saleh; Tom Volpe; Rich Margiasso; Xiang Li; Maria Chan; Xiaofeng Zhu; Xiaoli Tang
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.