Literature DB >> 19734460

Theoretical optimum of implant positional index design.

W Semper1, S Kraft, T Krüger, K Nelson.   

Abstract

Rotational freedom of the implant-abutment connection influences its screw joint stability; for optimization, influential factors need to be evaluated based on a previously developed closed formula. The underlying hypothesis is that the manufacturing tolerances, geometric pattern, and dimensions of the index do not influence positional stability. We used the dimensions of 5 commonly used implant systems with a clearance of 20 microm to calculate the extent of rotational freedom; a 3D simulation (SolidWorks) validated the analytical findings. Polygonal positional indices showed the highest degrees of rotational freedom. The polygonal profile displayed higher positional stability than the polygons, but less positional accuracy than the cam-groove connection. Features of a maximal rotation-safe positional index were determined. The analytical calculation of rotational freedom of implant positional indices is possible. Rotational freedom is dependent on the geometric design of the index and may be decreased by incorporating specific aspects into the positional index design.

Mesh:

Substances:

Year:  2009        PMID: 19734460     DOI: 10.1177/0022034509341243

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  5 in total

1.  Evaluation of impression accuracy for a four-implant mandibular model--a digital approach.

Authors:  Michael Stimmelmayr; Kurt Erdelt; Jan-Frederik Güth; Arndt Happe; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-10-19       Impact factor: 3.573

2.  Digital evaluation of the reproducibility of implant scanbody fit--an in vitro study.

Authors:  Michael Stimmelmayr; Jan-Frederik Güth; Kurt Erdelt; Daniel Edelhoff; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-06-04       Impact factor: 3.573

3.  Analytical and experimental position stability of the abutment in different dental implant systems with a conical implant-abutment connection.

Authors:  Wiebke Semper-Hogg; Silvan Kraft; Sebastian Stiller; Juergen Mehrhof; Katja Nelson
Journal:  Clin Oral Investig       Date:  2012-07-22       Impact factor: 3.573

4.  Influence of the connection design and titanium grades of the implant complex on resistance under static loading.

Authors:  Su-Jung Park; Suk-Won Lee; Richard Leesungbok; Su-Jin Ahn
Journal:  J Adv Prosthodont       Date:  2016-10-21       Impact factor: 1.904

5.  Effect of tightening torque on the marginal adaptation of cement-retained implant-supported fixed dental prostheses.

Authors:  Jalil Ghanbarzadeh; Hossin Dashti; Reza Karamad; Marzieh Alikhasi; Mohammadreza Nakhaei
Journal:  Dent Res J (Isfahan)       Date:  2015 Jul-Aug
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.