Theoretical considerations: implant positional index design.

W Semper1, S Kraft, T Krüger, K Nelson.   

Abstract

Rotational freedom of implant positional indices in two-piece implants was investigated. The aim of the study was to determine, analytically, the rotational freedom of three different positional index designs, based on the hypothesis that it is not influenced by their geometric principle. Regular polygonal, polygon profile, and cam-groove patterns were analyzed. Schematic descriptions were made and idealized equations developed. Parameters influencing the extent of rotational freedom were identified for the different positional index designs. A general equation that describes the rotational freedom of differently designed indices was also formulated. The present analysis showed that the rotational freedom of positional indices can be analytically calculated and is influenced by different parameters. The rotational freedom of the positional index of commonly used implant-abutment connections depends on their geometric design and size.

Mesh:

Substances:

Year:  2009        PMID: 19734459     DOI: 10.1177/0022034509341172

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  8 in total

1.  Evaluation of impression accuracy for a four-implant mandibular model--a digital approach.

Authors:  Michael Stimmelmayr; Kurt Erdelt; Jan-Frederik Güth; Arndt Happe; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-10-19       Impact factor: 3.573

2.  Digital evaluation of the reproducibility of implant scanbody fit--an in vitro study.

Authors:  Michael Stimmelmayr; Jan-Frederik Güth; Kurt Erdelt; Daniel Edelhoff; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-06-04       Impact factor: 3.573

3.  In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants.

Authors:  A Rack; T Rack; M Stiller; H Riesemeier; S Zabler; K Nelson
Journal:  J Synchrotron Radiat       Date:  2010-02-03       Impact factor: 2.616

4.  Analytical and experimental position stability of the abutment in different dental implant systems with a conical implant-abutment connection.

Authors:  Wiebke Semper-Hogg; Silvan Kraft; Sebastian Stiller; Juergen Mehrhof; Katja Nelson
Journal:  Clin Oral Investig       Date:  2012-07-22       Impact factor: 3.573

5.  Influence of the connection design and titanium grades of the implant complex on resistance under static loading.

Authors:  Su-Jung Park; Suk-Won Lee; Richard Leesungbok; Su-Jin Ahn
Journal:  J Adv Prosthodont       Date:  2016-10-21       Impact factor: 1.904

6.  Reverse torque evaluation in indexed and nonindexed abutments of Morse Taper implants in a mechanical fatigue test.

Authors:  Caio Marques Martins; Elimário Venturin Ramos; Simone Kreve; Geraldo Alberto Pinheiro de Carvalho; Aline Batista Gonçalves Franco; Luís Guilherme Scavone de Macedo; Alecsandro de Moura Silva; Sérgio Candido Dias
Journal:  Dent Res J (Isfahan)       Date:  2019 Mar-Apr

7.  Rotational tolerances of a titanium abutment in the as-received condition and after screw tightening in a conical implant connection.

Authors:  Rosario Prisco; Giuseppe Troiano; Luigi Laino; Khrystyna Zhurakivska
Journal:  J Adv Prosthodont       Date:  2021-12-22       Impact factor: 1.904

8.  Effect of tightening torque on the marginal adaptation of cement-retained implant-supported fixed dental prostheses.

Authors:  Jalil Ghanbarzadeh; Hossin Dashti; Reza Karamad; Marzieh Alikhasi; Mohammadreza Nakhaei
Journal:  Dent Res J (Isfahan)       Date:  2015 Jul-Aug
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.