Effect of manufacturer-inserted mask leaks on ventilator performance.

B Louis1, K Leroux, D Isabey, B Fauroux, F Lofaso.   

Abstract

Most pressure-support devices use a single circuit with an exhalation port integrated in the mask. The aim of the current study was to compare the effects of masks having different manufacturer-inserted leaks on ventilator performance. We simulated chronic obstructive pulmonary disease and restrictive disease. Four ventilators (VENTImotion (Weinmann, Hamburg, Germany), VPAP III STA (ResMed, Saint Priest, France), Synchrony 2 (Respironics, Nantes, France) and Vivo 40 (Breas, Saint Priest)) were tested with the recommended masks and with the masks having the largest and smallest leaks. Tests were performed with pressure support levels of 10, 15 and 20 cmH(2)O. The in vivo evaluation compared two ventilators using recommended masks opposed in terms of exhaled port resistance. The ventilators were tested with their recommended mask, and after mask exchange. The mask with the largest leak induced auto-triggering and/or increased inspiratory-trigger sensitivity was the VENTImotion under both simulated conditions and VPAP III STA under the simulated obstructive-disease condition. The mask with the smallest leak-increased inspiratory-trigger delay was Synchrony 2 in the simulated obstructive-disease condition and increased rebreathing. The in vivo study confirmed the bench results. When switching to a mask that has a different leak, evaluation is needed to adjust trigger sensitivity and pressurisation level and to check the absence of rebreathing.

Entities:  

Mesh:

Year:  2009        PMID: 19717475     DOI: 10.1183/09031936.00188708

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  10 in total

1.  Bench studies evaluating devices for non-invasive ventilation: critical analysis and future perspectives.

Authors:  Carlo Olivieri; Roberta Costa; Giorgio Conti; Paolo Navalesi
Journal:  Intensive Care Med       Date:  2011-11-29       Impact factor: 17.440

Review 2.  Basic Concepts for Tidal Volume and Leakage Estimation in Non-Invasive Ventilation.

Authors:  Manel Luján; Cristina Lalmolda; Begüm Ergan
Journal:  Turk Thorac J       Date:  2019-04-01

3.  Comparison of patient-ventilator interfaces based on their computerized effective dead space.

Authors:  R Fodil; F Lellouche; J Mancebo; G Sbirlea-Apiou; D Isabey; L Brochard; B Louis
Journal:  Intensive Care Med       Date:  2010-11-10       Impact factor: 17.440

4.  Performance characteristics of seven bilevel mechanical ventilators in pressure-support mode with different cycling criteria: a comparative bench study.

Authors:  Yuqing Chen; Kewen Cheng; Xin Zhou
Journal:  Med Sci Monit       Date:  2015-01-26

5.  Performance of ICU ventilators during noninvasive ventilation with large leaks in a total face mask: a bench study.

Authors:  Maria Aparecida Miyuki Nakamura; Eduardo Leite Vieira Costa; Carlos Roberto Ribeiro Carvalho; Mauro Roberto Tucci
Journal:  J Bras Pneumol       Date:  2014 May-Jun       Impact factor: 2.624

Review 6.  Technology for noninvasive mechanical ventilation: looking into the black box.

Authors:  Ramon Farré; Daniel Navajas; Josep M Montserrat
Journal:  ERJ Open Res       Date:  2016-03-11

7.  Typical within and between person variability in non-invasive ventilator derived variables among clinically stable, long-term users.

Authors:  Vishnu Jeganathan; Linda Rautela; Simon Conti; Krisha Saravanan; Alyssa Rigoni; Marnie Graco; Liam M Hannan; Mark E Howard; David J Berlowitz
Journal:  BMJ Open Respir Res       Date:  2021-03

8.  Quality versus emergency: How good were ventilation fittings produced by additive manufacturing to address shortages during the COVID19 pandemic?

Authors:  Roman Hossein Khonsari; Mathilde Oranger; Pierre-Marc François; Alexis Mendoza-Ruiz; Karl Leroux; Ghilas Boussaid; Delphine Prieur; Jean-Pierre Hodge; Antoine Belle; Vincent Midler; Capucine Morelot-Panzini; Maxime Patout; Jésus Gonzalez-Bermejo
Journal:  PLoS One       Date:  2022-04-21       Impact factor: 3.752

9.  Factors affecting abnormal triggering with non-invasive ventilators: A before-and-after study.

Authors:  Zhaoning Xu; Dongqin Sheng; Kefan Jiao; Chi Zhang; Junping Hao; Dedong Ma
Journal:  Clin Respir J       Date:  2022-05-31       Impact factor: 1.761

Review 10.  Practical Aspects of Interface Application in CPAP Treatment.

Authors:  Adel Bachour; Heidi Avellan-Hietanen; Tuula Palotie; Paula Virkkula
Journal:  Can Respir J       Date:  2019-11-03       Impact factor: 2.409

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.