Literature DB >> 19716484

An ex vivo comparison of working length determination by 3 electronic apex locators.

Elizeu Alvaro Pascon1, Massimo Marrelli, Orsola Congi, Rosetta Ciancio, Federica Miceli, Marco Aurélio Versiani.   

Abstract

OBJECTIVE: To compare the accuracy of 3 different electronic apex locators (EALs) in establishing the working length in recently extracted teeth. STUDY
DESIGN: Sixty teeth (100 canals) were soaked in an alginate model and electronically measured with 3 EALs (Dentaport ZX, Raypex 5, and Elements Diagnostic Unit and Apex Locator). The real working length was calculated as 1.0 mm short of the real length of the canal. The electronic measurements were taken following the manufacturers' orientations within +/-0.05 mm and +/-1.0 mm using a #15 K-file attached to the holder, after canal irrigation with 1% NaOCl. Data were analyzed with Friedman test and Wilcoxon signed rank test, at a significance level of 5%.
RESULTS: Within +/-0.5 mm and +/-1.0 mm, the accuracy was 39% and 90% (Dentaport ZX), 31% and 82% (Raypex 5), and 37% and 73% (Elements Diagnostic Unit and Apex Locator), respectively, with statistically significant differences between Elements Diagnostic Unit and Apex Locator and the other EALs.
CONCLUSION: None of the EALs yielded an accuracy of 100%. Within the limitations of the present study. Elements Diagnostic Unit and Apex Locator proved to be less reliable than Dentaport ZX and Raypex 5 in the determination of the real working length.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19716484     DOI: 10.1016/j.tripleo.2009.04.040

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  5 in total

1.  Accuracy of five electronic foramen locators with different operating systems: an ex vivo study.

Authors:  Bruno Carvalho de Vasconcelos; Michelli de Medeiros Bueno; Suyane Maria Luna-Cruz; Marco Antonio Hungaro Duarte; Carlos Augusto de Oliveira Fernandes
Journal:  J Appl Oral Sci       Date:  2013 Mar-Apr       Impact factor: 2.698

2.  Calcium hydroxide dressing residues after different removal techniques affect the accuracy of Root-ZX apex locator.

Authors:  Emel Uzunoglu; Ayhan Eymirli; Mehmet Özgür Uyanik; Semra Çalt; Emre Nagas
Journal:  Restor Dent Endod       Date:  2014-11-05

3.  Root ZX Electronic Foramen Locator: An Ex Vivo Study of Its Three Models' Precision and Reproducibility.

Authors:  Bernardo Almeida Aguiar; Rafael Santos Reinaldo; Luciana Maria Arcanjo Frota; Mônica Sampaio do Vale; Bruno Carvalho de Vasconcelos
Journal:  Int J Dent       Date:  2017-03-07

4.  The Precision of Propex Pixi with Different Instruments and Coronal Preflaring Procedures.

Authors:  Inês Ferreira; Ana Cristina Braga; Irene Pina-Vaz
Journal:  Eur Endod J       Date:  2019-07-10

5.  Evaluation of complications of root canal treatment performed by undergraduate dental students.

Authors:  Mothanna K AlRahabi
Journal:  Libyan J Med       Date:  2017-12       Impact factor: 1.657

  5 in total