Literature DB >> 19710219

Ultrasound guidance versus electrical stimulation for infraclavicular brachial plexus perineural catheter insertion.

Edward R Mariano1, Vanessa J Loland, Richard H Bellars, NavParkash S Sandhu, Michael L Bishop, Reid A Abrams, Matthew J Meunier, Rosalita C Maldonado, Eliza J Ferguson, Brian M Ilfeld.   

Abstract

OBJECTIVE: Electrical stimulation (ES)- and ultrasound-guided placement techniques have been described for infraclavicular brachial plexus perineural catheters but to our knowledge have never been previously compared in a randomized fashion, leaving the optimal method undetermined. We tested the hypothesis that infraclavicular catheters placed via ultrasound guidance alone require less time for placement and produce equivalent results compared with catheters placed solely via ES.
METHODS: Preoperatively, patients receiving an infraclavicular perineural catheter for distal upper extremity surgery were randomly assigned to either ES with a stimulating catheter or ultrasound guidance with a nonstimulating catheter. The primary outcome was the catheter insertion duration (minutes) starting when the ultrasound transducer (ultrasound group) or catheter placement needle (stimulation group) first touched the patient and ending when the catheter placement needle was removed after catheter insertion.
RESULTS: Perineural catheters placed with ultrasound guidance took a median (10th-90th percentile) of 9.0 (6.0-13.2) minutes compared with 15.0 (4.9-30.0) minutes for stimulation (P < .01). All ultrasound-guided catheters were successfully placed according to the protocol (n = 20) versus 70% in the stimulation group (n = 20; P < .01). All ultrasound-guided catheters resulted in a successful surgical block, whereas 2 catheters placed by stimulation failed to result in surgical anesthesia. Six catheters (30%) placed via stimulation resulted in vascular punctures compared with none in the ultrasound group (P < .01). Procedure-related pain scores were similar between groups (P = .34).
CONCLUSIONS: Placement of infraclavicular perineural catheters takes less time, is more often successful, and results in fewer inadvertent vascular punctures when using ultrasound guidance compared with ES.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19710219     DOI: 10.7863/jum.2009.28.9.1211

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  10 in total

Review 1.  Infraclavicular brachial plexus block in adults: a comprehensive review based on a unified nomenclature system.

Authors:  An-Chih Hsu; Yu-Ting Tai; Ko-Huan Lin; Han-Yun Yao; Han-Liang Chiang; Bing-Ying Ho; Sheng-Feng Yang; Jui-An Lin; Ching-Lung Ko
Journal:  J Anesth       Date:  2019-05-10       Impact factor: 2.078

2.  Ultrasound-guided perineural catheter insertion: three approaches but few illuminating data.

Authors:  Brian M Ilfeld; Michael J Fredrickson; Edward R Mariano
Journal:  Reg Anesth Pain Med       Date:  2010 Mar-Apr       Impact factor: 6.288

3.  The technique comparison of brachial plexus blocks by ultrasound guided with blocks by nerve stimulator guided.

Authors:  Guo-Ying Liu; Zhen-Qiang Chen; Hai-Yan Jia; Zhi-Gang Dai; Xue-Jun Zhang
Journal:  Int J Clin Exp Med       Date:  2015-09-15

4.  Comparative efficacy of ultrasound-guided and stimulating popliteal-sciatic perineural catheters for postoperative analgesia.

Authors:  Edward R Mariano; Vanessa J Loland; NavParkash S Sandhu; Michael L Bishop; Daniel K Lee; Alexandra K Schwartz; Paul J Girard; Eliza J Ferguson; Brian M Ilfeld
Journal:  Can J Anaesth       Date:  2010-08-11       Impact factor: 5.063

5.  Treating intractable phantom limb pain with ambulatory continuous peripheral nerve blocks: a pilot study.

Authors:  Brian M Ilfeld; Tobias Moeller-Bertram; Steven R Hanling; Kyle Tokarz; Edward R Mariano; Vanessa J Loland; Sarah J Madison; Eliza J Ferguson; Anya C Morgan; Mark S Wallace
Journal:  Pain Med       Date:  2013-03-14       Impact factor: 3.750

Review 6.  Ultrasound guidance for upper and lower limb blocks.

Authors:  Sharon R Lewis; Anastasia Price; Kevin J Walker; Ken McGrattan; Andrew F Smith
Journal:  Cochrane Database Syst Rev       Date:  2015-09-11

7.  The role of continuous peripheral nerve blocks.

Authors:  José Aguirre; Alicia Del Moral; Irina Cobo; Alain Borgeat; Stephan Blumenthal
Journal:  Anesthesiol Res Pract       Date:  2012-06-18

8.  Implementation of clinical practice changes by experienced anesthesiologists after simulation-based ultrasound-guided regional anesthesia training.

Authors:  T Edward Kim; Toni Ganaway; T Kyle Harrison; Steven K Howard; Cynthia Shum; Alex Kuo; Edward R Mariano
Journal:  Korean J Anesthesiol       Date:  2017-01-12

9.  Randomized comparison of popliteal-sciatic perineural catheter tip migration and dislocation in a cadaver model using two catheter designs.

Authors:  Lauren Steffel; Steven K Howard; Lindsay Borg; Edward R Mariano; Jody C Leng; T Edward Kim
Journal:  Korean J Anesthesiol       Date:  2016-10-25

Review 10.  Medical devices for the anesthetist: current perspectives.

Authors:  Jerry Ingrande; Hendrikus Jm Lemmens
Journal:  Med Devices (Auckl)       Date:  2014-03-25
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.