Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study.

Jung-Sun Kim1, Chunyu Fan, Donghoon Choi, Ik-Kyung Jang, Jung Myung Lee, Tae Hoon Kim, Sang Min Park, Sung Il Paik, Young-Guk Ko, Myeong-Ki Hong, Yangsoo Jang, Namsik Chung.   

Abstract

BACKGROUND: Acute coronary syndrome (ACS) is an independent risk factor for late stent thrombosis which might be related to the impaired vascular healing after drug-eluting stent (DES) due to the disruption of plaques and thrombus formation. Therefore, we investigated the vascular response after various DES implantations between ACS and stable angina pectoris (SAP) using optical coherence tomography (OCT).
METHODS: Ninety-one patients [49 ACS: 20 sirolimus-eluting (SES), 12 paclitaxel-eluting (PES) and 17 zotarolimus eluting stent (ZES) and 42 SAP: 15 SES, 12 PES and 15 ZES] underwent OCT at 9 months after stent implantation. Neointimal coverage and malapposition were evaluated in 21,939 struts in 2269-mm stented segments.
RESULTS: In the ACS group, the incidence of uncovered and malapposed struts was significantly higher (8.9 ± 13.7 vs 2.9 ± 6.2%, p = 0.01 and 2.2 ± 5.6 vs 0.5 ± 2.0%, p = 0.02). Among the three DESs tested, SES showed a significantly higher rate of uncovered struts in the ACS group (17.3 ± 13.4 vs 4.4 ± 6.2%, p = 0.003). PES had a trend toward higher rate of uncovered and malapposed struts in the ACS groups (6.7 ± 7.6 vs 4.0 ± 9.0%, p = 0.13) while ZES was similar in both groups.
CONCLUSION: The patterns of neointimal coverage and malapposition at 9months after DES implantation were different between ACS and SAP, and variable among the DES type between two groups. Therefore, the present study suggests that vascular response after DES implantation might be influenced by both clinical presentation and type of DES.
Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19709765     DOI: 10.1016/j.ijcard.2009.07.012

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  9 in total

1.  Neointimal tissue characteristics following sirolimus-eluting stent implantation: OCT quantitative tissue property analysis.

Authors:  Jingbo Hou; Haibo Jia; Haixia Liu; Zhigang Han; Shuang Yang; Chenyang Xu; Joseph Schmitt; Shaosong Zhang; Bo Yu; Ik-Kyung Jang
Journal:  Int J Cardiovasc Imaging       Date:  2012-03-16       Impact factor: 2.357

2.  Long-term (≥2 years) follow-up optical coherence tomographic study after sirolimus- and paclitaxel-eluting stent implantation: comparison to 9-month follow-up results.

Authors:  Tae-Hoon Kim; Jung-Sun Kim; Byoung-Keuk Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Int J Cardiovasc Imaging       Date:  2010-10-27       Impact factor: 2.357

3.  Neointimal coverage and vasodilator response to titanium-nitride-oxide-coated bioactive stents and everolimus-eluting stents in patients with acute coronary syndrome: insights from the BASE-ACS trial.

Authors:  Pasi Karjalainen; Tuomas O Kiviniemi; Tuomas Lehtinen; Wail Nammas; Antti Ylitalo; Antti Saraste; Jussi Mikkelsson; Mikko Pietila; Fausto Biancari; Juhani K E Airaksinen
Journal:  Int J Cardiovasc Imaging       Date:  2013-08-31       Impact factor: 2.357

4.  Major determinants for the uncovered stent struts on optical coherence tomography after drug-eluting stent implantation.

Authors:  Byeong-Keuk Kim; Jung-Sun Kim; Changmyung Oh; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Int J Cardiovasc Imaging       Date:  2011-05-31       Impact factor: 2.357

5.  Comparison of vascular responses after different types of second-generation drug-eluting stents implantation detected by optical coherence tomography.

Authors:  Hirofumi Ohtani; Shigeki Kimura; Tomoyo Sugiyama; Keiichi Hishikari; Toru Misawa; Masafumi Mizusawa; Kazuto Hayasaka; Yosuke Yamakami; Keisuke Kojima; Yuichiro Sagawa; Hiroyuki Hikita; Takashi Ashikaga; Atsushi Takahashi; Mitsuaki Isobe
Journal:  Int J Cardiovasc Imaging       Date:  2016-10-19       Impact factor: 2.357

6.  Stent strut coverage of titanium-nitride-oxide coated stent compared to paclitaxel-eluting stent in acute myocardial infarction: TITAX-OCT study.

Authors:  Tuomas Lehtinen; K E Juhani Airaksinen; Antti Ylitalo; Pasi P Karjalainen
Journal:  Int J Cardiovasc Imaging       Date:  2012-02-24       Impact factor: 2.357

7.  A Randomized Comparison of the Healing Response Between the Firehawk Stent and the Xience Stent in Patients With ST-Segment Elevation Myocardial Infarction at 6 Months of Follow-Up (TARGET STEMI OCT China Trial): An Optical Coherence Tomography Study.

Authors:  Yuan He; Rutao Wang; Jianzheng Liu; Fei Li; Jiayi Li; Chengxiang Li; Jingyu Zhou; Zhijing Zhao; Wangwei Yang; Fangjun Mou; Jing Wang; Jing Kan; Xiaobo Li; Yan Li; Ming Zheng; Shaoliang Chen; Chao Gao; Ling Tao
Journal:  Front Cardiovasc Med       Date:  2022-06-01

8.  Impact of statin treatment on strut coverage after drug-eluting stent implantation.

Authors:  Yongsung Suh; Byeong-Keuk Kim; Dong-Ho Shin; Jung-Sun Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Yonsei Med J       Date:  2015-01       Impact factor: 2.759

9.  Vascular response and intrastent thrombus in the early phase after drug-eluting versus bare-metal stent implantation in patients with ST-segment elevation myocardial infarction: An observational, single-center study.

Authors:  Nobuhiro Sato; Yoshiyasu Minami; Takao Shimohama; Ryo Kameda; Taiki Tojo; Junya Ako
Journal:  Health Sci Rep       Date:  2018-12-05