Literature DB >> 19706962

Comparison between PENELOPE and electron Monte Carlo simulations of electron fields used in the treatment of conjunctival lymphoma.

L Brualla1, R Palanco-Zamora, A Wittig, J Sempau, W Sauerwein.   

Abstract

For the treatment of conjunctival lymphoma in the early stages, external beam radiotherapy offers a curative approach. Such treatment requires the use of highly conformed small radiation beams. The beam size is so small that even advanced treatment planning systems have difficulties in calculating dose distributions. One possible approach for optimizing the treatment technique and later performing treatment planning is by means of full Monte Carlo (MC) simulations. In this paper, we compare experimental absorbed dose profiles obtained with a collimator used at the University Hospital Essen, with MC simulations done with the general-purpose radiation transport code PENELOPE. The collimator is also simulated with the hybrid MC code electron Monte Carlo (eMC) implemented in the commercial treatment planning system Eclipse (Varian). The results obtained with PENELOPE have a maximum difference with experimental data of 2.3%, whereas the eMC code differs systematically from the experimental data about 7% in the penumbra tails. We also show that PENELOPE simulations are able to obtain absorbed dose maps with an equivalent statistical uncertainty to the one found with eMC in similar CPU times.

Entities:  

Mesh:

Year:  2009        PMID: 19706962     DOI: 10.1088/0031-9155/54/18/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  PRIMO: a graphical environment for the Monte Carlo simulation of Varian and Elekta linacs.

Authors:  M Rodriguez; J Sempau; L Brualla
Journal:  Strahlenther Onkol       Date:  2013-09-06       Impact factor: 3.621

Review 2.  Monte Carlo systems used for treatment planning and dose verification.

Authors:  Lorenzo Brualla; Miguel Rodriguez; Antonio M Lallena
Journal:  Strahlenther Onkol       Date:  2016-11-25       Impact factor: 3.621

3.  Accurate estimation of dose distributions inside an eye irradiated with 106Ru plaques.

Authors:  L Brualla; J Sempau; F J Zaragoza; A Wittig; W Sauerwein
Journal:  Strahlenther Onkol       Date:  2012-11-18       Impact factor: 3.621

4.  Monte Carlo Simulation of the Treatment of Eye Tumors with (106)Ru Plaques: A Study on Maximum Tumor Height and Eccentric Placement.

Authors:  Lorenzo Brualla; Francisco J Zaragoza; Wolfgang Sauerwein
Journal:  Ocul Oncol Pathol       Date:  2014-05-07

5.  Monte Carlo Calculation of the Energy Spectrum of a 6 MeV Electron Beam using PENetration and Energy Loss of Positrons and Electrons Code.

Authors:  Danny Giancarlo Apaza Veliz; Jorge Homero Wilches Visbal; Felipe Chen Abrego; José Luis Vega Ramírez
Journal:  J Med Phys       Date:  2020-07-20

6.  Monte Carlo Simulation of the Treatment of Uveal Melanoma Using Measured Heterogeneous 106Ru Plaques.

Authors:  Francisco J Zaragoza; Marion Eichmann; Dirk Flühs; Andrea Wittig; Wolfgang Sauerwein; Lorenzo Brualla
Journal:  Ocul Oncol Pathol       Date:  2018-10-15

7.  Feasibility of a GATE Monte Carlo platform in a clinical pretreatment QA system for VMAT treatment plans using TrueBeam with an HD120 multileaf collimator.

Authors:  Boram Lee; Seonghoon Jeong; Kwangzoo Chung; Myonggeun Yoon; Hee Chul Park; Youngyih Han; Sang Hoon Jung
Journal:  J Appl Clin Med Phys       Date:  2019-09-23       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.