Literature DB >> 19706326

Application of micro-CT in small animal imaging.

Sebastian J Schambach1, Simona Bag, Lothar Schilling, Christoph Groden, Marc A Brockmann.   

Abstract

Over the past decade, the number of publications using micro-computed tomography (muCT) imaging in preclinical in vivo studies has risen exponentially. Higher spatial and temporal resolution are the key technical advancements that have allowed researchers to capture increasingly detailed anatomical images of small animals and to monitor the progression of disease in small animal models. The purpose of this review is to present the technical aspects of muCT, as well as current research applications. Our objectives are threefold: to familiarize the reader with the basics of muCT techniques; to present the type of experimental designs currently used; and to highlight limitations, future directions, in muCT-scanner research applications, and experimental methods. As a first step we present different muCT setups and components, as well as image contrast generation principles. We then present experimental approaches in order of the evaluated organ system. Finally, we provide a short summary of some of the technical limitations of muCT imaging and discuss potential future developments in muCT-scanner techniques and experimental setups. 2009. Published by Elsevier Inc.

Mesh:

Year:  2009        PMID: 19706326     DOI: 10.1016/j.ymeth.2009.08.007

Source DB:  PubMed          Journal:  Methods        ISSN: 1046-2023            Impact factor:   3.608


  106 in total

1.  An experimentally validated micromechanical model of a rat vertebra under compressive loading.

Authors:  Naomi Tsafnat; Stephen Wroe
Journal:  J Anat       Date:  2010-08-31       Impact factor: 2.610

2.  Improved quantification in multiple-pinhole SPECT by anatomy-based reconstruction using microCT information.

Authors:  Christian Vanhove; Michel Defrise; Axel Bossuyt; Tony Lahoutte
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-09-30       Impact factor: 9.236

3.  Investigation of Noise and Contrast Sensitivity of an Electron Multiplying Charge-Coupled Device (EMCCD) based Cone Beam Micro-CT System.

Authors:  Sumukh Bysani Krishnakumar; Alexander R Podgorsak; Sv Setlur Nagesh; Amit Jain; Stephen Rudin; Daniel R Bednarek; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-25

4.  Toward a new insight of calcium oxalate stones in Drosophila by micro-computerized tomography.

Authors:  Wen-Chi Chen; Huey-Yi Chen; Po-Chi Liao; Shih-Jing Wang; Ming-Yen Tsai; Yung-Hsiang Chen; Wei-Yong Lin
Journal:  Urolithiasis       Date:  2017-03-04       Impact factor: 3.436

5.  Intermittent Dosing with Sulindac Provides Effective Colorectal Cancer Chemoprevention in the Azoxymethane-Treated Mouse Model.

Authors:  Swati Chandra; Ariel C Nymeyer; Photini Faith Rice; Eugene W Gerner; Jennifer K Barton
Journal:  Cancer Prev Res (Phila)       Date:  2017-06-13

6.  Characterization of Continuous and Pulsed Emission modes of a Hybrid Micro Focus X-ray Source for Medical Imaging Applications.

Authors:  Muhammad U Ghani; Molly D Wong; Liqiang Ren; Di Wu; Bin Zheng; John X Rong; Xizeng Wu; Hong Liu
Journal:  Nucl Instrum Methods Phys Res A       Date:  2017-02-16       Impact factor: 1.455

Review 7.  Imaging technologies and basic considerations for welfare of laboratory rodents.

Authors:  Jordi L Tremoleda; Jane Sosabowski
Journal:  Lab Anim (NY)       Date:  2015-03       Impact factor: 12.625

8.  Contrast agents for quantitative microCT of lung tumors in mice.

Authors:  Kush Lalwani; Anand Giddabasappa; Danan Li; Peter Olson; Brett Simmons; Farbod Shojaei; Todd Van Arsdale; James Christensen; Amy Jackson-Fisher; Anthony Wong; Patrick B Lappin; Jeetendra Eswaraka
Journal:  Comp Med       Date:  2013       Impact factor: 0.982

9.  Time course of rapid bone loss and cortical porosity formation observed by longitudinal μCT in a rat model of CKD.

Authors:  Erin M B McNerny; Dorothy T Buening; Mohammad W Aref; Neal X Chen; Sharon M Moe; Matthew R Allen
Journal:  Bone       Date:  2019-05-03       Impact factor: 4.398

10.  RALBP1/RLIP76 depletion in mice suppresses tumor growth by inhibiting tumor neovascularization.

Authors:  Seunghyung Lee; Jeremy G T Wurtzel; Sharad S Singhal; Sanjay Awasthi; Lawrence E Goldfinger
Journal:  Cancer Res       Date:  2012-08-17       Impact factor: 12.701

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.