Evaluation of magnetic resonance imaging-compatible needles and interactive sequences for musculoskeletal interventions using an open high-field magnetic resonance imaging scanner.

Uta Wonneberger1, Bernhard Schnackenburg, Florian Streitparth, Thula Walter, Jens Rump, Ulf K M Teichgräber.   

Abstract

In this article, we study in vitro evaluation of needle artefacts and image quality for musculoskeletal laser-interventions in an open high-field magnetic resonance imaging (MRI) scanner at 1.0T with vertical field orientation. Five commercially available MRI-compatible puncture needles were assessed based on artefact characteristics in a CuSO4 phantom (0.1%) and in human cadaveric lumbar spines. First, six different interventional sequences were evaluated with varying needle orientation to the main magnetic field B0 (0 degrees to 90 degrees ) in a sequence test. Artefact width, needle-tip error, and contrast-to-noise ratio (CNR) were calculated. Second, a gradient-echo sequence used for thermometric monitoring was assessed and in varying echo times, artefact width, tip error, and signal-to-noise ratio (SNR) were measured. Artefact width and needle-tip error correlated with needle material, instrument orientation to B0, and sequence type. Fast spin-echo sequences produced the smallest needle artefacts for all needles, except for the carbon fibre needle (width <3.5 mm, tip error <2 mm) at 45 degrees to B0. Overall, the proton density-weighted spin-echo sequences had the best CNR (CNR(Muscle/Needle) >16.8). Concerning the thermometric gradient echo sequence, artefacts remained <5 mm, and the SNR reached its maximum at an echo time of 15 ms. If needle materials and sequences are accordingly combined, guidance and monitoring of musculoskeletal laser interventions may be feasible in a vertical magnetic field at 1.0T.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19705200     DOI: 10.1007/s00270-009-9676-6

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  8 in total

1.  In vivo measurement of the subchondral bone thickness of lumbar facet joint using magnetic resonance imaging.

Authors:  C Y Duan; A A Espinoza Orías; S Shott; H S An; G B J Andersson; J Z Hu; H B Lu; N Inoue
Journal:  Osteoarthritis Cartilage       Date:  2010-10-27       Impact factor: 6.576

2.  [Percutaneous interventions in an open MR system: technical background and clinical indications].

Authors:  F Fischbach; K Fischbach; J Ricke
Journal:  Radiologe       Date:  2013-11       Impact factor: 0.635

3.  MR guidance and thermometry of percutaneous laser disc decompression in open MRI: an initial clinical investigation.

Authors:  Florian Streitparth; Tony Hartwig; Thula Walter; Maximilian De Bucourt; Michael Putzier; Patrick Strube; Tina Bretschneider; Patrick Freyhardt; Martin Maurer; Diane Renz; Bernhard Gebauer; Bernd Hamm; Ulf K M Teichgräber
Journal:  Eur Radiol       Date:  2013-05-09       Impact factor: 5.315

4.  Reduced k-space acquisition to accelerate MR imaging of moving interventional instruments: a phantom study.

Authors:  Jens Christian Rump; Martin Jonczyk; Christian Jürgen Seebauer; Florian Streitparth; Felix Victor Güttler; Ulf Karl-Martin Teichgräber; Bernd Hamm
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-03-17       Impact factor: 2.924

5.  In vitro artefact assessment of a new MR-compatible microwave antenna and a standard MR-compatible radiofrequency ablation electrode for tumour ablation.

Authors:  Rüdiger Hoffmann; Hansjörg Rempp; Frank Eibofner; David-Emanuel Keßler; Gunnar Blumenstock; Jakob Weiß; Philippe L Pereira; Konstantin Nikolaou; Stephan Clasen
Journal:  Eur Radiol       Date:  2015-07-02       Impact factor: 5.315

6.  Recurrent osteoid osteoma: interstitial laser ablation under magnetic resonance imaging guidance.

Authors:  Florian Streitparth; Ulf Teichgräber; Thula Walter; Klaus Dieter Schaser; Bernhard Gebauer
Journal:  Skeletal Radiol       Date:  2010-06-19       Impact factor: 2.199

7.  MR-guided discography using an open 1 Tesla MRI system.

Authors:  Florian Streitparth; T Hartwig; B Schnackenburg; P Strube; M Putzier; S Chopra; M De Bucourt; B Hamm; U Teichgräber
Journal:  Eur Radiol       Date:  2010-11-30       Impact factor: 5.315

8.  Artefact and ablation performance of an MR-conditional high-power microwave system in bovine livers: an ex vivo study.

Authors:  Antonia Grimm; Moritz Winkelmann; Jakob Weiß; Georg Gohla; Gunnar Blumenstock; Konstantin Nikolaou; Stephan Clasen; Rüdiger Hoffmann
Journal:  Eur Radiol Exp       Date:  2019-09-23
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.