Literature DB >> 19696470

Preliminary experimental results on controlled cardiac computed tomography: a phantom study.

Yang Lu1, Zhijun Cai, Ge Wang, Jun Zhao, Er-Wei Bai.   

Abstract

In this paper, we present the preliminary experimental results on controlled cardiac computed tomography (CT), which aims to reduce the motion artifacts by means of controlling the x-ray source rotation speed. An innovative cardiac phantom enables us to perform this experiment without modifying the scanner. It is the first experiment on the cardiac CT with speed controlled x-ray source. Experimental results demonstrate that the proposed method successfully separates the phantom images at different phases (improve the temporal resolution) through controlling the x-ray speed.

Entities:  

Mesh:

Year:  2009        PMID: 19696470      PMCID: PMC2856312          DOI: 10.3233/XST-2009-0221

Source DB:  PubMed          Journal:  J Xray Sci Technol        ISSN: 0895-3996            Impact factor:   1.535


  18 in total

1.  Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT.

Authors:  S Achenbach; S Ulzheimer; U Baum; M Kachelriess; D Ropers; T Giesler; W Bautz; W G Daniel; W A Kalender; W Moshage
Journal:  Circulation       Date:  2000-12-05       Impact factor: 29.690

2.  A preliminary study on adaptive field-of-view tracking in peripheral digital subtraction angiography.

Authors:  J R Bennett; E W Bai; J I Halloran; G Wang
Journal:  J Xray Sci Technol       Date:  2003-01-01       Impact factor: 1.535

3.  Image reconstruction in peripheral and central regions-of-interest and data redundancy.

Authors:  Xiaochuan Pan; Yu Zou; Dan Xia
Journal:  Med Phys       Date:  2005-03       Impact factor: 4.071

4.  Dual-source CT cardiac imaging: initial experience.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Bernd J Wintersperger; Alexander W Leber; Franz von Ziegler; Carsten Rist; Sonja Buhmann; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-05-13       Impact factor: 5.315

5.  Selectable source rotational velocity for cardiac computed tomography.

Authors:  Jie Liu; Chenglin Wang; Ying Liu; Erwei Bai; Ge Wang
Journal:  J Comput Assist Tomogr       Date:  2007 Jan-Feb       Impact factor: 1.826

6.  Tiny a priori knowledge solves the interior problem in computed tomography.

Authors:  Hiroyuki Kudo; Matias Courdurier; Frédéric Noo; Michel Defrise
Journal:  Phys Med Biol       Date:  2008-04-09       Impact factor: 3.609

7.  [Dynamic cardiovascular studies with electron beam computed tomography].

Authors:  E Mousseaux; A Hernigou; M Auguste; J C Gaux
Journal:  J Radiol       Date:  1994-12

8.  Adaptive Bolus Chasing Computed Tomography Angiography: Control Scheme and Experimental Results.

Authors:  Zhijun Cai; Colbin Erdahl; Kai Zeng; Tom Potts; Melhem Sharafuddin; Osama Saba; Ge Wang; Er-Wei Bai
Journal:  Biomed Signal Process Control       Date:  2008-10       Impact factor: 3.880

9.  Preliminary report on in vivo coronary MRA at 3 Tesla in humans.

Authors:  Matthias Stuber; René M Botnar; Stefan E Fischer; Rolf Lamerichs; Jouke Smink; Paul Harvey; Warren J Manning
Journal:  Magn Reson Med       Date:  2002-09       Impact factor: 4.668

10.  A general local reconstruction approach based on a truncated hilbert transform.

Authors:  Yangbo Ye; Hengyong Yu; Yuchuan Wei; Ge Wang
Journal:  Int J Biomed Imaging       Date:  2007
View more
  1 in total

1.  Dose reduction with adaptive bolus chasing computed tomography angiography.

Authors:  Zhijun Cai; Er-Wei Bai; Ge Wang; Melhem J Sharafuddin; Hicham T Abada
Journal:  J Xray Sci Technol       Date:  2010       Impact factor: 1.535

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.