Literature DB >> 19695984

Wavelet-domain medical image denoising using bivariate laplacian mixture model.

Hossein Rabbani1, Reza Nezafat, Saeed Gazor.   

Abstract

In this paper, we proposed novel noise reduction algorithms that can be used to enhance image quality in various medical imaging modalities such as magnetic resonance and multidetector computed tomography. The noisy captured 3-D data are first transformed by discrete complex wavelet transform. Using a nonlinear function, we model the data as the sum of the clean data plus additive Gaussian or Rayleigh noise. We use a mixture of bivariate Laplacian probability density functions for the clean data in the transformed domain. The MAP and minimum mean-squared error (MMSE) estimators allow us to efficiently reduce the noise. The employed prior distribution is mixture and bivariate, and thus accurately characterizes the heavy-tail distribution of clean images and exploits the interscale properties of wavelets coefficients. In addition, we estimate the parameters of the model using local information; as a result, the proposed denoising algorithms are spatially adaptive, i.e., the intrascale dependency of wavelets is also well exploited in the enhancement process. The proposed approach results in significant noise reduction while the introduced distortions are not noticeable as a result of accurate statistical modeling. The obtained shrinkage functions have closed form, are simple in implementation, and efficiently enhances data. Our experiments on CT images show that among our derived shrinkage functions usually BiLapGausMAP produces images with higher peak SNR. However, BiLapGausMMSE is preferred especially for CT images, which have high SNRs. Furthermore, BiLapRayMAP yields better noise reduction performance for low SNR MR datasets such as high-resolution whole heart imaging while BiLapGauMAP results in better performance in MR data with higher intrinsic SNR such as functional cine data.

Entities:  

Mesh:

Year:  2009        PMID: 19695984     DOI: 10.1109/TBME.2009.2028876

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  9 in total

1.  Efficient denoising technique for CT images to enhance brain hemorrhage segmentation.

Authors:  H S Bhadauria; M L Dewal
Journal:  J Digit Imaging       Date:  2012-12       Impact factor: 4.056

2.  Data valuation for medical imaging using Shapley value and application to a large-scale chest X-ray dataset.

Authors:  Siyi Tang; Amirata Ghorbani; Rikiya Yamashita; Sameer Rehman; Jared A Dunnmon; James Zou; Daniel L Rubin
Journal:  Sci Rep       Date:  2021-04-16       Impact factor: 4.379

3.  Segmentation Based Sparse Reconstruction of Optical Coherence Tomography Images.

Authors:  Leyuan Fang; Shutao Li; David Cunefare; Sina Farsiu
Journal:  IEEE Trans Med Imaging       Date:  2016-09-20       Impact factor: 10.048

4.  Adaptively Tuned Iterative Low Dose CT Image Denoising.

Authors:  SayedMasoud Hashemi; Narinder S Paul; Soosan Beheshti; Richard S C Cobbold
Journal:  Comput Math Methods Med       Date:  2015-05-24       Impact factor: 2.238

5.  Subspace-based technique for speckle noise reduction in ultrasound images.

Authors:  Norashikin Yahya; Nidal S Kamel; Aamir S Malik
Journal:  Biomed Eng Online       Date:  2014-11-25       Impact factor: 2.819

6.  Images denoising for COVID-19 chest X-ray based on multi-resolution parallel residual CNN.

Authors:  Xiaoben Jiang; Yu Zhu; Bingbing Zheng; Dawei Yang
Journal:  Mach Vis Appl       Date:  2021-06-28       Impact factor: 2.012

7.  Hardware design and implementation of a wavelet de-noising procedure for medical signal preprocessing.

Authors:  Szi-Wen Chen; Yuan-Ho Chen
Journal:  Sensors (Basel)       Date:  2015-10-16       Impact factor: 3.576

8.  Bio-signal and System Modeling: From Image Processing to System Biology.

Authors:  Hossein Rabbani; Shaghayegh Haghjooy Javanmar
Journal:  J Med Signals Sens       Date:  2013-01

9.  Optical Coherence Tomography Noise Reduction Using Anisotropic Local Bivariate Gaussian Mixture Prior in 3D Complex Wavelet Domain.

Authors:  Hossein Rabbani; Milan Sonka; Michael D Abramoff
Journal:  Int J Biomed Imaging       Date:  2013-10-10
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.