Literature DB >> 19684954

Stress analysis on the free-end distal extension of an implant-supported mandibular complete denture.

Gustavo Diniz Greco1, Wellington Corrêa Jansen, Janis Landre Junior, Paulo Isaías Seraidarian.   

Abstract

A comparative and qualitative analysis of the tensions generated in the cantilever region of an implant-supported mandibular complete denture was conducted using the three-dimensional finite element method. The mechanical properties of the components were input in the model and a load of 15 N was applied in pre-determined points. In the first simulation, the load was applied on the occlusal surface of the first premolar. In the second simulation, it was applied on the first and second premolars. In the third simulation, it was applied on the first and second premolars and on the first molar. The different occlusion patterns produced similar tension distributions in the cantilever region, which followed a similar pattern in the three simulations. In all of the cases, the highest levels of tension were located in the region of the first implant. However, as the loads were dislocated distally, the tensions increased considerably. The more extensive the cantilever, the more compromised will be the infrastructure, the prosthetic components and the implants. Regardless of the length of the cantilever, the highest tensions will always be located in the region of the implant next to the load application point.

Mesh:

Substances:

Year:  2009        PMID: 19684954     DOI: 10.1590/s1806-83242009000200014

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  6 in total

1.  Evaluation of immediately loaded mandibular four vertical versus tilted posterior implants supporting fixed detachable restorations without versus with posterior cantilevers.

Authors:  Latifa Abdallah Mohamed; Mohamed Moataz Khamis; Ahlam Mostafa El-Sharkawy; Rania Abdelaziz Fahmy
Journal:  Oral Maxillofac Surg       Date:  2021-08-29

2.  Wear of double crown systems: electroplated vs. casted female part.

Authors:  Stefan Bayer; Dominik Kraus; Ludger Keilig; Lina Gölz; Helmut Stark; Norbert Enkling
Journal:  J Appl Oral Sci       Date:  2012 May-Jun       Impact factor: 2.698

3.  Effect of cantilever length on stress distribution around implants in mandibular overdentures supported by two and three implants.

Authors:  Behnaz Ebadian; Ramin Mosharraf; Niloufar Khodaeian
Journal:  Eur J Dent       Date:  2016 Jul-Sep

4.  Effect of the number of abutments on biomechanics of Branemark prosthesis with straight and tilted distal implants.

Authors:  Marcos Michelon Naconecy; Tomás Geremia; André Cervieri; Eduardo Rolim Teixeira; Rosemary Sadami Shinkai
Journal:  J Appl Oral Sci       Date:  2010 Mar-Apr       Impact factor: 2.698

5.  Stress analysis of mandibular implant overdentures retained with one, two, or four ball attachments: A finite element study.

Authors:  Mohamed M El-Zawahry; Eman M Ibraheem; Mohammad Zakaria Nassani; Sahar A Ghorab; Mohamed I El-Anwar
Journal:  Dent Res J (Isfahan)       Date:  2018 Nov-Dec

6.  Evaluation of stress distribution of implant-retained mandibular overdenture with different vertical restorative spaces: A finite element analysis.

Authors:  Behnaz Ebadian; Mahmoud Farzin; Saeid Talebi; Niloufar Khodaeian
Journal:  Dent Res J (Isfahan)       Date:  2012-11
  6 in total