Literature DB >> 19683151

Clinical outcomes and postoperative intraocular optical quality with a microincision aberration-free aspheric intraocular lens.

Jorge L Alió1, David P Piñero, Dolores Ortiz, Raúl Montalbán.   

Abstract

PURPOSE: To evaluate the visual outcomes and optical quality with an aspheric intraocular lens (IOL) with no aberration in microincision cataract surgery.
SETTING: Vissum-Instituto de Oftalmológico de Alicante, Alicante, Spain.
METHODS: This prospective cohort study included eyes that had cataract surgery with implantation of an Akreos Adapt Advanced Optics MI60 IOL. Surgery was performed using the Millennium phacoemulsification platform. The IOL was implanted through a sub-1.8 mm incision using the 1.8 Viscoglide cartridge. Visual and refractive outcomes were analyzed during a 12-month follow-up. In addition, postoperative ocular optical quality was evaluated using the Optical Quality Analysis System. Postoperative intraocular optical aberrations were calculated by subtracting corneal aberrations from total aberrations.
RESULTS: The cohort comprised 25 eyes of 25 patients ranging in age from 52 to 83 years. The mean spherical equivalent was -0.47 diopters +/- 0.62 (SD) 3 months postoperatively (P = .72). The mean corrected distance visual acuity improved from 0.54 +/- 0.23 logMAR preoperatively to 0.08 +/- 0.16 logMAR 3 months postoperatively (P<.01). Optical quality analysis showed a mean spatial frequency at 50% of the modulation transfer function (MTF) of 2.85 +/- 0.55 cycles per degree (cpd) and a mean cutoff MTF frequency of 21.50 +/- 7.02 cpd. Postoperatively, the mean intraocular spherical aberration was 0.16 +/- 0.11 microm and the mean primary coma root mean square, 0.23 +/- 0.15 microm.
CONCLUSION: Implantation of the aberration-free aspheric IOL was safe and effective and provided excellent visual and refractive outcomes with good optical performance.

Entities:  

Mesh:

Year:  2009        PMID: 19683151     DOI: 10.1016/j.jcrs.2009.03.055

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  6 in total

1.  Early clinical outcome with a new monofocal microincision intraocular lens.

Authors:  Baha Toygar; Ozge Yabas Kiziloglu; Okan Toygar; Ali Murat Hacimustafaoglu
Journal:  Int Ophthalmol       Date:  2016-01-16       Impact factor: 2.031

2.  Early outcomes of vision and objective visual quality analysis after cataract surgery with trifocal intraocular lens implantation.

Authors:  Mei-Fang Chu; Na Hui; Cong-Yi Wang; Lei Yu; Bo Ma; Yan Li; Cheng Pei
Journal:  Int J Ophthalmol       Date:  2019-10-18       Impact factor: 1.779

3.  A comparable study of clinical and optical outcomes after 1.8, 2.0 mm microcoaxial and 3.0 mm coaxial cataract surgery.

Authors:  Yi-Bo Yu; Ya-Nan Zhu; Wei Wang; Yi-Dong Zhang; Yin-Hui Yu; Ke Yao
Journal:  Int J Ophthalmol       Date:  2016-03-18       Impact factor: 1.779

4.  A comparative study on visual and optical performance of Akreos AO and Kontur AB IOLs after phacoemulsification cataract surgery.

Authors:  Hamid Gharaee; Masoud Zabihifard; Alireza Eslampour; Samira Hassanzadeh; Masoud Shafiee
Journal:  J Curr Ophthalmol       Date:  2016-03-28

5.  Visual and refractive outcomes of new intraocular lens implantation after cataract surgery.

Authors:  Bhupesh Singh; Sourabh Sharma; Neha Bharti; Dharitri Samantrey; Dadan J Paandey; Sudhank Bharti
Journal:  Sci Rep       Date:  2022-08-18       Impact factor: 4.996

6.  Using Optical Quality Analysis System for predicting surgical parameters in age-related cataract patients.

Authors:  Thibaud Garcin; Damien Grivet; Gilles Thuret; Philippe Gain
Journal:  PLoS One       Date:  2020-10-12       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.