Literature DB >> 19680900

Characterisation of vitamin B12 immunoaffinity columns and method development for determination of vitamin B12 in a range of foods, juices and pharmaceutical products using immunoaffinity clean-up and high performance liquid chromatography with UV detection.

E C Marley1, E Mackay, G Young.   

Abstract

New rapid and simpler procedures, using immunoaffinity columns, have been developed for the determination of vitamin B12 in a range of samples including three different US National Institute of Standard and Technology (NIST) Reference Materials, infant formula, powdered energy drinks and bars, wheat breakfast cereal, carbonated soft drinks, fruit juices and vitamin B12 tablets. The procedures involved extraction of vitamin B12 using water or sodium acetate buffer and enzyme digestion (using pepsin or alpha-amylase, or both) if necessary. The extract was clarified and passed through "EASI-EXTRACT Vitamin B12", an immunoaffinity column containing monoclonal antibody with high affinity and specificity to vitamin B12. Subsequently, the vitamin B12 immunoaffinity column was washed with 10 ml water and the vitamin B12 was released from the column with 3 ml methanol. Following evaporation, the samples were reconstituted in mobile phase and analysed by HPLC-UV at 361 nm on an ACE 3AQ analytical column using a gradient elution consisting of 0.025% trifluoroacetic acid in water and acetonitrile. Analysis of three types of NIST Standard Reference Materials in triplicate demonstrated the results of the immunoaffinity column method were comparable to microbiological assay results. Method repeatability was determined for all samples analysed and ranged between 0.8 and 10%, demonstrating the method was repeatable with complex matrices (NIST 2383) containing low levels of vitamin B12 (0.44 microg per 100 g), as well as simpler matrices, such as vitamin tablets containing high levels (2000 microg per 0.849 g) of vitamin B12.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19680900     DOI: 10.1080/02652030802429104

Source DB:  PubMed          Journal:  Food Addit Contam Part A Chem Anal Control Expo Risk Assess        ISSN: 1944-0057


  3 in total

1.  A Stability-Indicating HPLC Method for the Determination of Nitrosylcobalamin (NO-Cbl), a Novel Vitamin B12 Analog.

Authors:  Michael J Dunphy; Annette M Sysel; Joseph A Lupica; Kristie Griffith; Taylor Sherrod; Joseph A Bauer
Journal:  Chromatographia       Date:  2014-04-01       Impact factor: 2.044

2.  Characterization of vitamin B12 in Dunaliella salina.

Authors:  Anantharajappa Kumudha; Ravi Sarada
Journal:  J Food Sci Technol       Date:  2015-09-02       Impact factor: 2.701

3.  The efficiency of ultrasonic-assisted extraction of cyanocobalamin is greater than heat extraction.

Authors:  Maria V Chandra-Hioe; Han Xu; Jayashree Arcot
Journal:  Heliyon       Date:  2019-12-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.