Literature DB >> 19679280

Mechanisms of recurrent aortic regurgitation after aortic valve repair: predictive value of intraoperative transesophageal echocardiography.

Jean-Benoît le Polain de Waroux1, Anne-Catherine Pouleur, Annie Robert, Agnès Pasquet, Bernhard L Gerber, Philippe Noirhomme, Gébrine El Khoury, Jean-Louis J Vanoverschelde.   

Abstract

OBJECTIVES: The aim of the present study was to examine the intraoperative echocardiographic features associated with recurrent severe aortic regurgitation (AR) after an aortic valve repair surgery.
BACKGROUND: Surgical valve repair for AR has significant advantages over valve replacement, but little is known about the predictors and mechanisms of its failure.
METHODS: We blindly reviewed all clinical, pre-operative, intraoperative, and follow-up transesophageal echocardiographic data of 186 consecutive patients who underwent valve repair for AR during a 10-year period and in whom intraoperative and follow-up echo data were available. After a median follow-up duration of 18 months, 41 patients had recurrent 3+ AR, 23 patients presented with residual 1+ to 2+ AR, and 122 had no or trivial AR. In patients with recurrent 3+ AR, the cause of recurrent AR was the rupture of a pericardial patch in 3 patients, a residual cusp prolapse in 26 patients, a restrictive cusp motion in 9 patients, an aortic dissection in 2 patients, and an infective endocarditis in 1 patient.
RESULTS: Pre-operatively, all 3 groups were similar for aortic root dimensions and prevalence of bicuspid valve (overall 37%). Patients with recurrent AR were more likely to display Marfan syndrome or type 3 dysfunction pre-operatively. At the opposite end, patients with continent AR repair at follow-up were more likely to have type 2 dysfunction pre-operatively. After cardiopulmonary bypass, a shorter coaptation length, the degree of cusp billowing, a lower level of coaptation (relative to the annulus), a larger diameter of the aortic annulus and the sino-tubular junction, the presence of a residual AR, and the width of its vena contracta were associated with the presence of AR at follow-up. Multivariate Cox analysis identified a shorter coaptation length (odds ratio [OR]: 0.8, p = 0.05), a coaptation occurring below the level of the aortic annulus (OR: 7.9, p < 0.01), a larger aortic annulus (OR: 1.2, p = 0.01), and residual aortic regurgitation (OR: 5.3, p = 0.01) as risk factors of repair failure.
CONCLUSIONS: Our results demonstrate that intraoperative transesophageal echocardiography can be used to identify patients undergoing AR repair who are at increased risk for late repair failure.

Entities:  

Mesh:

Year:  2009        PMID: 19679280     DOI: 10.1016/j.jcmg.2009.04.013

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  27 in total

1.  Complications after aortic valve repair and valve-sparing procedures.

Authors:  Michel Van Dyck; David Glineur; Laurent de Kerchove; Gébrine El Khoury
Journal:  Ann Cardiothorac Surg       Date:  2013-01

2.  Aortic valve repair in children.

Authors:  Yves d'Udekem
Journal:  Ann Cardiothorac Surg       Date:  2013-01

3.  Valve sparing root replacement: the remodeling technique with external ring annuloplasty.

Authors:  Emmanuel Lansac; Isabelle Di Centa; Jan Vojacek; Jan Nijs; Jaroslav Hlubocky; Gianclaudio Mecozzi; Mathieu Debauchez
Journal:  Ann Cardiothorac Surg       Date:  2013-01

4.  The role of echocardiography in aortic valve repair.

Authors:  Jean-Louis Vanoverschelde; Michel van Dyck; Bernhard Gerber; David Vancraeynest; Julie Melchior; Christophe de Meester; Agnès Pasquet
Journal:  Ann Cardiothorac Surg       Date:  2013-01

Review 5.  Aortic valve repair update.

Authors:  Tatsuhiko Komiya
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-02-05

Review 6.  Toward standardization of valve-sparing root replacement and annuloplasty.

Authors:  Takashi Kunihara
Journal:  Gen Thorac Cardiovasc Surg       Date:  2018-09-17

Review 7.  The role of transesophageal echocardiography in aortic valve preserving procedures.

Authors:  Terri Hall; Pallav Shah; Sudhir Wahi
Journal:  Indian Heart J       Date:  2014 May-Jun

Review 8.  Why I choose to repair and not to replace the aortic valve?

Authors:  Athanasios Antoniou; Amer Harky; Mohamad Bashir; Gebrine El Khoury
Journal:  Gen Thorac Cardiovasc Surg       Date:  2018-04-05

Review 9.  Aortic valve sparing root surgery for Marfan syndrome.

Authors:  George Matalanis; Nisal K Perera
Journal:  Ann Cardiothorac Surg       Date:  2017-11

10.  A framework for designing patient-specific bioprosthetic heart valves using immersogeometric fluid-structure interaction analysis.

Authors:  Fei Xu; Simone Morganti; Rana Zakerzadeh; David Kamensky; Ferdinando Auricchio; Alessandro Reali; Thomas J R Hughes; Michael S Sacks; Ming-Chen Hsu
Journal:  Int J Numer Method Biomed Eng       Date:  2018-01-25       Impact factor: 2.747

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.