Literature DB >> 19675992

Dynamic interface pressure distributions of two transtibial prosthetic socket concepts.

Tim Dumbleton1, Arjan W P Buis, Angus McFadyen, Brendan F McHugh, Geoff McKay, Kevin D Murray, Sandra Sexton.   

Abstract

In this study, we investigated and compared the dynamic interface pressure distribution of hands-off and hands-on transtibial prosthetic systems by means of pressure mapping. Of the 48 established unilateral amputees recruited, half (n = 24) had been wearing pressure-cast prostheses (IceCast Compact) and the other half (n = 24) had been wearing hand-cast sockets of the patellar tendon bearing design. We measured the dynamic pressure profile of more than 90% of the area within each prosthetic socket by means of four Tekscan F-Scan socket transducer arrays. We compared the interface pressure between socket concepts. We found that the distribution of dynamic pressure at the limb-socket interface was similar for the two intervention (socket prescription) groups. However, a significant difference was found in the magnitude of the interface pressure between the two socket concepts; the interface pressures recorded in the hands-off sockets were higher than those seen in the hands-on concept. Despite the differences in interface pressure, the level of satisfaction with the sockets was similar between subject groups. The sockets instrumented for this study had been in daily use for at least 6 months, with no residual-limb health problems.

Mesh:

Year:  2009        PMID: 19675992

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  15 in total

1.  Evaluation of Force Sensing Resistors for the Measurement of Interface Pressures in Lower Limb Prosthetics.

Authors:  Eric Swanson; Ethan Weathersby; John Cagle; Joan E Sanders
Journal:  J Biomech Eng       Date:  2019-04-24       Impact factor: 2.097

2.  A digital patient for computer-aided prosthesis design.

Authors:  Giorgio Colombo; Giancarlo Facoetti; Caterina Rizzi
Journal:  Interface Focus       Date:  2013-04-06       Impact factor: 3.906

3.  Device to monitor sock use in people using prosthetic limbs: technical report.

Authors:  Joan E Sanders; Revathi Murthy; John C Cagle; Katheryn J Allyn; Reid H Phillips; Brian P Otis
Journal:  J Rehabil Res Dev       Date:  2012

4.  Amputee socks: thickness of multiple socks.

Authors:  John C Cagle; Alan J Yu; Marcia A Ciol; Joan E Sanders
Journal:  Prosthet Orthot Int       Date:  2013-11-15       Impact factor: 1.895

5.  Clinical implication of interface pressure for a new prosthetic suspension system.

Authors:  Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Nasrul Anuar Abd Razak
Journal:  Biomed Eng Online       Date:  2014-06-30       Impact factor: 2.819

6.  Comparative study between Dermo, Pelite, and Seal-In X5 liners: effect on patient's satisfaction and perceived problems.

Authors:  Sadeeq Ali; Noor Azuan Abu Osman; Nooranida Arifin; Hossein Gholizadeh; Nasrul Anwar Abd Razak; Wan Abu Bakar Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-11

7.  Piezoelectric bimorphs' characteristics as in-socket sensors for transfemoral amputees.

Authors:  Amr M El-Sayed; Nur Azah Hamzaid; Noor Azuan Abu Osman
Journal:  Sensors (Basel)       Date:  2014-12-10       Impact factor: 3.576

Review 8.  The use of fiber Bragg grating sensors in biomechanics and rehabilitation applications: the state-of-the-art and ongoing research topics.

Authors:  Ebrahim Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahamd Adikan
Journal:  Sensors (Basel)       Date:  2012-09-25       Impact factor: 3.576

9.  The capability of fiber Bragg grating sensors to measure amputees' trans-tibial stump/socket interface pressures.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Arezoo Eshraghi; Faisal Rafiq Mahamd Adikan
Journal:  Sensors (Basel)       Date:  2013-08-12       Impact factor: 3.576

Review 10.  Review of the socket design and interface pressure measurement for transtibial prosthesis.

Authors:  Gh Pirouzi; N A Abu Osman; A Eshraghi; S Ali; H Gholizadeh; W A B Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.