Literature DB >> 19672655

Subjective sleep quality during average volume assured pressure support (AVAPS) ventilation in patients with hypercapnic COPD: a physiological pilot study.

Ernesto Crisafulli1, Giuseppe Manni, Marika Kidonias, Ludovico Trianni, Enrico M Clini.   

Abstract

The aim of this short-term, single-blind, randomized, crossover study was to evaluate night-time efficacy of and compliance and physiological responses to average volume assured pressure support (AVAPS) versus pressure support (PS) ventilation. AVAPS or PS ventilation was delivered to nine stable hypercapnic COPD patients via a mask over two 5-day periods during consecutive weeks. The Synchrony ventilator was used to deliver mask ventilation as follows: 8 ml/kg of ideal body weight (as the targeted inspiratory tidal volume) with IPAP ranging from EPAP up to 30 cmH(2)O for AVAPS, and the patient's highest tolerated IPAP level for PS. EPAP was set at the minimum level for both modalities and oxygen was added at a fixed inspiratory fraction to maintain SaO(2) above 90%. Arterial blood gases, comfort (by VAS), and perceived sleep efficiency (SE by questionnaire) were measured at baseline (T0) and after three (T1) and five (T2) nights over the two periods. Compliance to ventilation, as measured by mean usage (hours/night), was also recorded. Measurements were similar between the two treatment periods at baseline. PaCO(2) and comfort VAS similarly improved for both modalities, whereas the SE score significantly improved at T2 with AVAPS (from 5.1 +/- 2.0 to 4.1 +/- 2.2, P = 0.001) but not with PS (from 5.1 +/- 1.7 to 4.7 +/- 1.3, P = 0.219). No difference in mean usage was found between the two modalities. Mask AVAPS is as comfortable and effective as PS at reducing respiratory acidosis but produces better perceived sleep efficiency in stable hypercapnic COPD patients.

Entities:  

Mesh:

Year:  2009        PMID: 19672655     DOI: 10.1007/s00408-009-9167-1

Source DB:  PubMed          Journal:  Lung        ISSN: 0341-2040            Impact factor:   2.584


  26 in total

1.  Effects of noninvasive positive pressure ventilation on gas exchange and sleep in COPD patients.

Authors:  S L Krachman; A J Quaranta; T J Berger; G J Criner
Journal:  Chest       Date:  1997-09       Impact factor: 9.410

2.  Outcome of patients with stable COPD receiving controlled noninvasive positive pressure ventilation aimed at a maximal reduction of Pa(CO2).

Authors:  Wolfram Windisch; Sergej Kostić; Michael Dreher; Johann Christian Virchow; Stephan Sorichter
Journal:  Chest       Date:  2005-08       Impact factor: 9.410

3.  Efficacy of nocturnal nasal ventilation in stable, severe chronic obstructive pulmonary disease during a 3-month controlled trial.

Authors:  P C Gay; R D Hubmayr; R W Stroetz
Journal:  Mayo Clin Proc       Date:  1996-06       Impact factor: 7.616

4.  Domiciliary nocturnal nasal intermittent positive pressure ventilation in COPD: mechanisms underlying changes in arterial blood gas tensions.

Authors:  M W Elliott; D A Mulvey; J Moxham; M Green; M A Branthwaite
Journal:  Eur Respir J       Date:  1991-10       Impact factor: 16.671

5.  Sleep and non-invasive ventilation in patients with chronic respiratory insufficiency.

Authors:  Cristina Ambrogio; Xazmin Lowman; Ming Kuo; Joshua Malo; Anil R Prasad; Sairam Parthasarathy
Journal:  Intensive Care Med       Date:  2008-09-16       Impact factor: 17.440

6.  Outcome of COPD patients performing nocturnal non-invasive mechanical ventilation.

Authors:  E Clini; C Sturani; R Porta; C Scarduelli; V Galavotti; M Vitacca; N Ambrosino
Journal:  Respir Med       Date:  1998-10       Impact factor: 3.415

7.  Nasal pressure support ventilation plus oxygen compared with oxygen therapy alone in hypercapnic COPD.

Authors:  D J Meecham Jones; E A Paul; P W Jones; J A Wedzicha
Journal:  Am J Respir Crit Care Med       Date:  1995-08       Impact factor: 21.405

8.  Nocturnal positive-pressure ventilation via nasal mask in patients with severe chronic obstructive pulmonary disease.

Authors:  D A Strumpf; R P Millman; C C Carlisle; L M Grattan; S M Ryan; A D Erickson; N S Hill
Journal:  Am Rev Respir Dis       Date:  1991-12

9.  Physiologic evaluation of 4 weeks of nocturnal nasal positive pressure ventilation in stable hypercapnic patients with chronic obstructive pulmonary disease.

Authors:  S Nava; F Fanfulla; P Frigerio; P Navalesi
Journal:  Respiration       Date:  2001       Impact factor: 3.580

Review 10.  Respiratory disorders during sleep in chronic obstructive pulmonary disease.

Authors:  Oreste Marrone; Adriana Salvaggio; Giuseppe Insalaco
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2006
View more
  10 in total

1.  Can we improve sleep quality by changing the way we ventilate patients?

Authors:  Marios Roussos; Sairam Parthasarathy; Najib T Ayas
Journal:  Lung       Date:  2009-10-21       Impact factor: 2.584

2.  Average volume-assured pressure support vs conventional bilevel pressure support in pediatric nocturnal hypoventilation: a case series.

Authors:  Vishal Saddi; Ganesh Thambipillay; Sonia Pithers; Miles Moody; Bradley Martin; Gregory Blecher; Arthur Teng
Journal:  J Clin Sleep Med       Date:  2021-05-01       Impact factor: 4.062

3.  Nocturnal respiratory failure in a child with congenital myopathy - management using average volume-assured pressure support (AVAPS).

Authors:  Natalie Gentin; Bruce Williamson; Ganesh Thambipillay; Arthur Teng
Journal:  Respirol Case Rep       Date:  2015-08-18

4.  Comparison of BPAP S/T and Average Volume-Assured Pressure Support Modes for Hypercapnic Respiratory Failure in the Emergency Department: A Randomized Controlled Trial.

Authors:  Nurfer Zehra Gören; Emre Şancı; Feride Fulya Ercan Coşkun; Duygu Gürsoylu; Başak Bayram
Journal:  Balkan Med J       Date:  2021-09       Impact factor: 2.021

5.  Apnea-Hypopnea Index in Chronic Obstructive Pulmonary Disease Exacerbation Requiring Noninvasive Mechanical Ventilation with Average Volume-Assured Pressure Support.

Authors:  Killen H Briones-Claudett; Adela Romero Lopez; Mónica H Briones-Claudett; Mariuxi Del Pilar Cabrera Baños; Killen H Briones Zamora; Diana C Briones Marquez; Andrea P Icaza-Freire; Luc J I Zimmermann; Antonio W D Gavilanes; Michelle Grunauer
Journal:  Crit Care Res Pract       Date:  2021-11-27

6.  Noninvasive Mechanical Ventilation with Average Volume-Assured Pressure Support versus BiPAP S/T in De Novo Hypoxemic Respiratory Failure.

Authors:  Killen H Briones-Claudett; Mónica H Briones-Claudett; Mariuxi Del Pilar Cabrera Baños; Killen H Briones Zamora; Diana C Briones Marquez; Luc J I Zimmermann; Antonio W D Gavilanes; Michelle Grunauer
Journal:  Crit Care Res Pract       Date:  2022-08-03

7.  Positive outcome of average volume-assured pressure support mode of a Respironics V60 Ventilator in acute exacerbation of chronic obstructive pulmonary disease: a case report.

Authors:  Miyuki Okuda; Makoto Kashio; Nobuya Tanaka; Takashi Fujii; Yoshinari Okuda
Journal:  J Med Case Rep       Date:  2012-09-10

8.  Use of volume-targeted non-invasive bilevel positive airway pressure ventilation in a patient with amyotrophic lateral sclerosis.

Authors:  Montserrat Diaz-Abad; John Edward Brown
Journal:  J Bras Pneumol       Date:  2014 Jul-Aug       Impact factor: 2.624

9.  Effect of average volume-assured pressure support treatment on health-related quality of life in COPD patients with chronic hypercapnic respiratory failure: a randomized trial.

Authors:  Doaa M Magdy; Ahmed Metwally
Journal:  Respir Res       Date:  2020-03-06

Review 10.  Novel modes of non-invasive ventilation in chronic respiratory failure: a narrative review.

Authors:  Neeraj Mukesh Shah; Rebecca F D'Cruz; Patrick B Murphy
Journal:  J Thorac Dis       Date:  2020-10       Impact factor: 2.895

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.