Literature DB >> 19672321

An electric impedance based microelectromechanical system flow sensor for ionic solutions.

H Edward Ayliffe1, Rd Rabbitt.   

Abstract

Microfluidic devices with channel cross sections measuring 4 × 10 μm(2) instrumented with gold microelectrodes were used to sense flow rates of ionic solutions on the basis of electric impedance (EI) measured perpendicular to the flow. Negative pressures were applied to access ports of the microdevices to generate flow of saline solutions (physiologic concentrations 0.9%) through the micro-EI recording zone with flow rates between 2.4 and 4.8 μl min(-1). The EI spectra (100 Hz-20 MHz) recorded under flow conditions were compared with the no-flow condition. Changes in the magnitude of EI (at 350 Hz) for flow rates as low as 2.4 μl min(-1) were statistically significant compared with the no-flow condition. The observed dependence of EI on flow rate is attributed to the relative difference between the rate of migration of charge-balancing electrolyte ions to the electrode surface and the rate of removal of the same ions by forced convection. An electrochemical convection-diffusion model was used to study the observed dependence on flow. Simulations support the conceptual model that passing DC current from the gold electrodes into the ionic solution results in an increase in ionic concentration near the electrode surface (due to the inward migration of counter-balancing ions). When the fluid flow rates increase, these counter-balancing ions are replaced by the bulk solution, thereby lowering the average ionic concentration within the recording zone. This local concentration drop results in an increase in the real part of the impedance.

Entities:  

Year:  2003        PMID: 19672321      PMCID: PMC2723957          DOI: 10.1088/0957-0233/14/8/318

Source DB:  PubMed          Journal:  Meas Sci Technol        ISSN: 0957-0233            Impact factor:   2.046


  3 in total

1.  The polarization impedance of common electrode metals operated at low current density.

Authors:  T Ragheb; L A Geddes
Journal:  Ann Biomed Eng       Date:  1991       Impact factor: 3.934

2.  Linear AC electrode polarization impedance at smooth noble metal interfaces.

Authors:  J F DeRosa; R B Beard
Journal:  IEEE Trans Biomed Eng       Date:  1977-05       Impact factor: 4.538

3.  Electrode polarization impedance and measurements in biological materials.

Authors:  H P Schwan
Journal:  Ann N Y Acad Sci       Date:  1968-02-01       Impact factor: 5.691

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.