Amar Agarwal1, Rupal H Trivedi, Soosan Jacob, Mandeep Lamba, Athiya Agarwal, Sunita Agarwal.
Abstract
Subluxation of the capsular tension ring (CTR) into the vitreous is a rare complication. The explantation of these rings from the vitreous by conventional vitrectomy is often a difficult procedure requiring great surgical skill. We report two cases of posteriorly subluxated endocapsular rings, which were explanted with pars plana vitrectomy using the chandelier illumination system. This illumination system has an external light source which is incorporated via a fibreoptic into the infusion cannula, thereby freeing both hands of the surgeon. This allows surgeon to easily perform bimanual intraocular maneuvers such as external scleral indentation, manipulation of CTR in the vitreous cavity and removal of these rings with the handshake technique.Entities:
Keywords: capsular tension ring; chandelier illumination system; vitrectomy; zonular dialysis
Year: 2007 PMID: 19668482 PMCID: PMC2701134
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Figure 1Case 2. Both eyelets of the CTR seen during intravitreal bimanual manipulation under chandelier illumination system.