Literature DB >> 19663946

A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions.

Irena Sailer1, Alexander Philipp, Anja Zembic, Bjarni E Pjetursson, Christoph H F Hämmerle, Marcel Zwahlen.   

Abstract

OBJECTIVES: The objective of this systematic review was to assess the 5-year survival rates and incidences of complications associated with ceramic abutments and to compare them with those of metal abutments.
METHODS: An electronic Medline search complemented by manual searching was conducted to identify randomized-controlled clinical trials, and prospective and retrospective studies providing information on ceramic and metal abutments with a mean follow-up time of at least 3 years. Patients had to have been examined clinically at the follow-up visit. Assessment of the identified studies and data abstraction was performed independently by three reviewers. Failure rates were analyzed using standard and random-effects Poisson regression models to obtain summary estimates of 5-year survival proportions.
RESULTS: Twenty-nine clinical and 22 laboratory studies were selected from an initial yield of 7136 titles and data were extracted. The estimated 5-year survival rate of ceramic abutments was 99.1% [95% confidence interval (CI): 93.8-99.9%] and 97.4% (95% CI: 96-98.3%) for metal abutments. The estimated cumulative incidence of technical complications after 5 years was 6.9% (95% CI: 3.5-13.4%) for ceramic abutments and 15.9% (95% CI: 11.6-21.5%) for metal abutments. Abutment screw loosening was the most frequent technical problem, occurring at an estimated cumulative incidence after 5 years of 5.1% (95% CI: 3.3-7.7%). All-ceramic crowns supported by ceramic abutments exhibited similar annual fracture rates as metal-ceramic crowns supported by metal abutments. The cumulative incidence of biological complications after 5 years was estimated at 5.2% (95% CI: 0.4-52%) for ceramic and 7.7% (95% CI: 4.7-12.5%) for metal abutments. Esthetic complications tended to be more frequent at metal abutments. A meta-analysis of the laboratory data was impossible due to the non-standardized test methods of the studies included.
CONCLUSION: The 5-year survival rates estimated from annual failure rates appeared to be similar for ceramic and metal abutments. The information included in this review did not provide evidence for differences of the technical and biological outcomes of ceramic and metal abutments. However, the information for ceramic abutments was limited in the number of studies and abutments analyzed as well as the accrued follow-up time. Standardized methods for the analysis of abutment strength are needed.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19663946     DOI: 10.1111/j.1600-0501.2009.01787.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  36 in total

1.  Tooth-implant-supported posterior fixed dental prostheses with zirconia frameworks: 3-year clinical result.

Authors:  Florian Beuer; Caroline Sachs; Julian Groesser; Jan-Frederik Gueth; Michael Stimmelmayr
Journal:  Clin Oral Investig       Date:  2015-09-24       Impact factor: 3.573

2.  Mechanical performance of cement- and screw-retained all-ceramic single crowns on dental implants.

Authors:  Matthias Obermeier; Oliver Ristow; Kurt Erdelt; Florian Beuer
Journal:  Clin Oral Investig       Date:  2017-07-15       Impact factor: 3.573

3.  Fracture behavior of straight or angulated zirconia implant abutments supporting anterior single crowns.

Authors:  Frank P Nothdurft; Klaus E Doppler; Kurt J Erdelt; Andreas W Knauber; Peter R Pospiech
Journal:  Clin Oral Investig       Date:  2010-01-19       Impact factor: 3.573

Review 4.  Emerging ceramic-based materials for dentistry.

Authors:  I Denry; J R Kelly
Journal:  J Dent Res       Date:  2014-10-01       Impact factor: 6.116

5.  The effect of abrading and cutting instruments on machinability of dental ceramics.

Authors:  Satoshi Sakoda; Noriko Nakao; Ikuya Watanabe
Journal:  J Mater Sci Mater Med       Date:  2018-03-16       Impact factor: 3.896

6.  Mechanical stability of angulated zirconia abutments supporting maxillary anterior single crowns on narrow-diameter implants.

Authors:  Ruiyang Ma; Ping Yu; Yuqiang Zhang; Chenyang Xie; Xin Tan; Jikui Sun; Haiyang Yu
Journal:  Clin Oral Investig       Date:  2022-09-26       Impact factor: 3.606

7.  Randomized clinical trial of implant-supported ceramic-ceramic and metal-ceramic fixed dental prostheses: preliminary results.

Authors:  Josephine F Esquivel-Upshaw; Arthur E Clark; Jonathan J Shuster; Kenneth J Anusavice
Journal:  J Prosthodont       Date:  2013-06-12       Impact factor: 2.752

8.  Influence of preparation depths on the fracture load of customized zirconia abutments with titanium insert.

Authors:  Han-Sung Joo; Hong-So Yang; Sang-Won Park; Hyun-Seung Kim; Kwi-Dug Yun; Min-Kyung Ji; Hyun-Pil Lim
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

9.  Microscopical and chemical surface characterization of CAD/CAM zircona abutments after different cleaning procedures. A qualitative analysis.

Authors:  Peter Gehrke; Astrid Tabellion; Carsten Fischer
Journal:  J Adv Prosthodont       Date:  2015-04-23       Impact factor: 1.904

10.  Rationale for the use of CAD/CAM technology in implant prosthodontics.

Authors:  Jaafar Abduo; Karl Lyons
Journal:  Int J Dent       Date:  2013-04-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.