Literature DB >> 19663392

Membrane-based electrochemical nanobiosensor for the detection of virus.

Binh T T Nguyen1, Guiwan Koh, Hui Si Lim, Anthony J S Chua, Mary M L Ng, Chee-Seng Toh.   

Abstract

A membrane-based electrochemical nanobiosensor sensitive toward whole viral particles is fabricated by forming a submicrometer thick nanoporous alumina membrane over a platinum disk electrode. Antibody probe molecules are physically adsorbed onto the walls of the membrane nanochannels. The sensing signal is based on the monitoring of the electrode's Faradaic current response toward ferrocenemethanol, which is extremely sensitive to the formation of immunocomplex within the nanoporous membrane. This nanobiosensor is demonstrated for the sensing of West Nile virus protein domain III (WNV-DIII) and the inactivated West Nile viral particle, using anti-WNV-DIII immunoglobulin M (IgM) as the biorecognition probe. The detection of the viral protein and the particle are logarithmically linear up to 53 pg mL(-1) (R(2) = 0.99) and 50 viral particles per 100 mL (R(2) = 0.93) in pH 7, with extremely low detection limits of 4 pg mL(-1) and ca. 2 viral particles per 100 mL, comparable to sensitivities of polymerase chain reaction techniques. The relative standard deviation (RSD) of whole viral particle detection in whole blood serum is 6.9%. In addition, the simple nanobiosensor construction procedure, minimal sample preparation, and short detection time of 30 min are highly attractive properties and demonstrate that the detection of a wide range of proteins and viruses can be achieved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19663392     DOI: 10.1021/ac900761a

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  12 in total

Review 1.  Electrochemical sensors.

Authors:  Benjamin J Privett; Jae Ho Shin; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2010-06-15       Impact factor: 6.986

Review 2.  Electrochemical biosensors for pathogen detection.

Authors:  Ellen Cesewski; Blake N Johnson
Journal:  Biosens Bioelectron       Date:  2020-04-12       Impact factor: 10.618

Review 3.  Single nanoparticle detectors for biological applications.

Authors:  Abdulkadir Yurt; George G Daaboul; John H Connor; Bennett B Goldberg; M Selim Ünlü
Journal:  Nanoscale       Date:  2012-01-03       Impact factor: 7.790

4.  Fabrication of Fine Electrodes on the Tip of Hypodermic Needle Using Photoresist Spray Coating and Flexible Photomask for Biomedical Applications.

Authors:  Joho Yun; Jinhwan Kim; Jong-Hyun Lee
Journal:  J Vis Exp       Date:  2017-11-28       Impact factor: 1.355

5.  Nanomaterials-Based Sensors for Respiratory Viral Detection: A Review.

Authors:  Gowhar A Naikoo; Tasbiha Awan; Israr Ul Hassan; Hiba Salim; Fareeha Arshad; Waqar Ahmed; Abdullah M Asiri; Ahsanulhaq Qurashi
Journal:  IEEE Sens J       Date:  2021-05-31       Impact factor: 4.325

Review 6.  Recent progress in West Nile virus diagnosis and vaccination.

Authors:  Marina De Filette; Sebastian Ulbert; Mike Diamond; Niek N Sanders
Journal:  Vet Res       Date:  2012-03-01       Impact factor: 3.683

Review 7.  Nanostructural Engineering of Nanoporous Anodic Alumina for Biosensing Applications.

Authors:  Josep Ferré-Borrull; Josep Pallarès; Gerard Macías; Lluis F Marsal
Journal:  Materials (Basel)       Date:  2014-07-18       Impact factor: 3.623

8.  Ultrasensitive cDNA detection of dengue virus RNA using electrochemical nanoporous membrane-based biosensor.

Authors:  Varun Rai; Hapuarachchige C Hapuarachchi; Lee Ching Ng; Siew Hwa Soh; Yee Sin Leo; Chee-Seng Toh
Journal:  PLoS One       Date:  2012-08-23       Impact factor: 3.240

Review 9.  Nanomaterial-based biosensors for detection of pathogenic virus.

Authors:  Ahad Mokhtarzadeh; Reza Eivazzadeh-Keihan; Paria Pashazadeh; Maryam Hejazi; Nasrin Gharaatifar; Mohammad Hasanzadeh; Behzad Baradaran; Miguel de la Guardia
Journal:  Trends Analyt Chem       Date:  2017-10-13       Impact factor: 12.296

10.  Porous Alumina Membrane-Based Electrochemical Biosensor for Protein Biomarker Detection in Chronic Wounds.

Authors:  Gayathri Rajeev; Elizabeth Melville; Allison J Cowin; Beatriz Prieto-Simon; Nicolas H Voelcker
Journal:  Front Chem       Date:  2020-03-06       Impact factor: 5.221

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.