Literature DB >> 19662916

Clinical results of a corneal radius correcting factor in calculating intraocular lens power after corneal refractive surgery.

Nicola Rosa1, Luigi Capasso, Michele Lanza, Maria Borrelli.   

Abstract

PURPOSE: To describe the clinical results of a corneal radius correcting factor (CRCF), which is based on the axial length and independent of knowledge from the previous surgical procedure, in calculating intraocular lens (IOL) power in eyes that developed cataract after corneal refractive surgery.
METHODS: Intraocular lens power for 62 eyes that previously underwent corneal refractive surgery was calculated with the SRK/T and SRK II formulas using an axial length-related CRCF, and the expected refractive errors were compared with the actual postoperative refractive errors.
RESULTS: Using the CRCF, the refractive outcomes ranged between -3.25 and +1.00 diopters (D) (mean -0.41+/-0.75 D), with 37 (60%) eyes within +/-0.50 D and 53 (85%) eyes within +/-1.00 D of the intended refraction. Using the raw data, without the correcting factor, the refractive outcomes would have ranged between -2.00 and +5.00 D (mean +2.17+/-1.45 D) with 7 (11%) eyes within +/-0.50 D and 15 (24%) eyes within +/- 1.00 D of the intended refraction.
CONCLUSIONS: Pending further validation through a larger prospective evaluation, the CRCF combined with the SRK/T formula is recommended in eyes with an axial length up to 30 mm and the average IOL power calculated with the SRK/T and SRK II formulas when the axial length is >30 mm.

Entities:  

Mesh:

Year:  2009        PMID: 19662916     DOI: 10.3928/1081597X-20090610-05

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  10 in total

1.  Postoperative refractive error following cataract surgery after the first attack of acute primary angle closure.

Authors:  Tadayuki Nishide; Natsuki Hayakawa; Ikuko Kimura; Misako Nakanishi; Yoko Yagi; Etsuko Shibuya; Nobuhisa Mizuki
Journal:  Int Ophthalmol       Date:  2014-08       Impact factor: 2.031

Review 2.  IOL power calculation after corneal refractive surgery.

Authors:  Maddalena De Bernardo; Luigi Capasso; Luisa Caliendo; Francesco Paolercio; Nicola Rosa
Journal:  Biomed Res Int       Date:  2014-07-21       Impact factor: 3.411

3.  Corneal biomechanical parameters in pellucid marginal degeneration.

Authors:  Maddalena De Bernardo; Palmiro Cornetta; Giuseppe Marotta; Nicola Rosa
Journal:  J Curr Ophthalmol       Date:  2018-06-23

4.  Intraocular Pressure after Myopic Photorefractive Keratectomy.

Authors:  Maddalena De Bernardo; Nicola Rosa
Journal:  J Ophthalmic Vis Res       Date:  2018 Oct-Dec

5.  Axial Length Shortening After Cataract Surgery: New Approach to Solve the Question.

Authors:  Maddalena De Bernardo; Giulio Salerno; Palmiro Cornetta; Nicola Rosa
Journal:  Transl Vis Sci Technol       Date:  2018-12-27       Impact factor: 3.283

6.  Comparison of the Orbscan II topographer and the iTrace aberrometer for the measurements of keratometry and corneal diameter in myopic patients.

Authors:  Yao Chen; Xiaobo Xia
Journal:  BMC Ophthalmol       Date:  2016-03-31       Impact factor: 2.209

7.  Accuracy of Corneal Power Measurements for Intraocular Lens Power Calculation after Myopic Laser In situ Keratomileusis.

Authors:  Hany A Helaly; Mohammad A M El-Hifnawy; Mohamed Shafik Shaheen; Amr F Abou El-Kheir
Journal:  Middle East Afr J Ophthalmol       Date:  2016 Jan-Mar

8.  Calculation of Unknown Preoperative K Readings in Postrefractive Surgery Patients.

Authors:  Nicola Rosa; Maddalena De Bernardo; Maria Borrelli
Journal:  J Ophthalmol       Date:  2018-02-11       Impact factor: 1.909

9.  Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus.

Authors:  Maddalena De Bernardo; Nicola Rosa
Journal:  J Optom       Date:  2018-02-01

10.  Improving accuracy of corneal power measurement with partial coherence interferometry after corneal refractive surgery using a multivariate polynomial approach.

Authors:  Michele Lanza; Robert Koprowski; Mario Bifani Sconocchia
Journal:  Biomed Eng Online       Date:  2018-08-13       Impact factor: 2.819

  10 in total