BACKGROUND AND OBJECTIVES: A bicarbonate dialysate acidified with citrate (CD) has been reported to have local anticoagulant effect. This study examines the effect of CD on dialysis efficiency, measured as eKt/Vurea, and predialysis concentrations of BUN, creatinine, phosphate, and beta-2 microglobulin in chronic dialysis units. DESIGN, SETTINGS, PARTICIPANTS, & MEASUREMENTS: Three outpatient chronic hemodialysis units with 142 patients were switched to CD for 6 mo. Using each patient's prior 6 mo on regular bicarbonate dialysate acidified by acetate (AD) as control, eKt/Vurea was compared with that of CD. Follow-up data for 7 mo after the study were collected from about one-half of the participants remaining on CD and the others returned to AD. RESULTS: eKt/Vurea, increased (P < 0.0001) from pre-CD value of 1.51 +/- 0.01 to 1.57 +/- 0.01 with CD. During CD use beta-2 microglobulin levels declined (P = 0.0001) from 28.1 +/- 10.0 to 25.9 +/- 10.0. Similarly, the concentrations of BUN, creatinine, and phosphate also decreased on CD (P < 0.008). In the poststudy period, eKt/Vurea for the patients staying on CD remained unchanged at 1.60 +/- 0.17 versus 1.59 +/- 0.18 (P = NS), whereas in those returning to AD the eKt/Vurea decreased from 1.55 +/- 0.20 to 1.52 +/- 0.17 (P < 0.0001). CONCLUSIONS: Data suggest that CD use is associated with increased solute removal.
RCT Entities:
BACKGROUND AND OBJECTIVES: A bicarbonate dialysate acidified with citrate (CD) has been reported to have local anticoagulant effect. This study examines the effect of CD on dialysis efficiency, measured as eKt/Vurea, and predialysis concentrations of BUN, creatinine, phosphate, and beta-2 microglobulin in chronic dialysis units. DESIGN, SETTINGS, PARTICIPANTS, & MEASUREMENTS: Three outpatient chronic hemodialysis units with 142 patients were switched to CD for 6 mo. Using each patient's prior 6 mo on regular bicarbonate dialysate acidified by acetate (AD) as control, eKt/Vurea was compared with that of CD. Follow-up data for 7 mo after the study were collected from about one-half of the participants remaining on CD and the others returned to AD. RESULTS: eKt/Vurea, increased (P < 0.0001) from pre-CD value of 1.51 +/- 0.01 to 1.57 +/- 0.01 with CD. During CD use beta-2 microglobulin levels declined (P = 0.0001) from 28.1 +/- 10.0 to 25.9 +/- 10.0. Similarly, the concentrations of BUN, creatinine, and phosphate also decreased on CD (P < 0.008). In the poststudy period, eKt/Vurea for the patients staying on CD remained unchanged at 1.60 +/- 0.17 versus 1.59 +/- 0.18 (P = NS), whereas in those returning to AD the eKt/Vurea decreased from 1.55 +/- 0.20 to 1.52 +/- 0.17 (P < 0.0001). CONCLUSIONS: Data suggest that CD use is associated with increased solute removal.
Authors: Mareille Gritters; Muriël P C Grooteman; Margreet Schoorl; Marianne Schoorl; Piet C M Bartels; Peter G Scheffer; Tom Teerlink; Casper G Schalkwijk; Marieke Spreeuwenberg; Menso J Nubé Journal: Nephrol Dial Transplant Date: 2005-09-06 Impact factor: 5.992
Authors: Damien Ashby; Natalie Borman; James Burton; Richard Corbett; Andrew Davenport; Ken Farrington; Katey Flowers; James Fotheringham; R N Andrea Fox; Gail Franklin; Claire Gardiner; R N Martin Gerrish; Sharlene Greenwood; Daljit Hothi; Abdul Khares; Pelagia Koufaki; Jeremy Levy; Elizabeth Lindley; Jamie Macdonald; Bruno Mafrici; Andrew Mooney; James Tattersall; Kay Tyerman; Enric Villar; Martin Wilkie Journal: BMC Nephrol Date: 2019-10-17 Impact factor: 2.388
Authors: Pablo Ureña-Torres; Brian Bieber; Fitsum Guebre-Egziabher; Rim Ossman; Michel Jadoul; Masaaki Inaba; Bruce M Robinson; Friedrich Port; Christian Jacquelinet; Christian Combe Journal: Kidney360 Date: 2021-02-04
Authors: Davina J Tai; Kelvin Leung; Pietro Ravani; Robert R Quinn; Nairne Scott-Douglas; Jennifer M MacRae Journal: BMC Nephrol Date: 2015-08-25 Impact factor: 2.388