Literature DB >> 19657850

FDTD simulations to assess the performance of CFMA-434 applicators for superficial hyperthermia.

H Petra Kok1, Martijn De Greef, Davi Correia, Paul J Zum Vörde Sive Vörding, Gerard Van Stam, Edward A Gelvich, Arjan Bel, Johannes Crezee.   

Abstract

INTRODUCTION: Contact flexible microstrip applicators (CFMA), operating at 434 MHz, are applied at the Academic Medical Center (AMC) for superficial hyperthermia (e.g. chest wall recurrences and melanoma). This paper investigates the performance of CFMA, evaluating the stability of the specific absorption rate (SAR) distribution, effective heating depth (EHD) and effective field size (EFS) under different conditions.
METHODS: Simulations were performed using finite differences and were compared to existing measurement data, performed using a rectangular phantom with a superficial fat-equivalent layer of 1 cm and filled with saline solution. The electrode plates of the applicators measure approximately 7 x 20, 29 x 21 and 20 x 29 cm(2). Bolus thickness varied between 1 and 2 cm. The impact of the presence of possible air layers between the rubber frame and the electrodes on the SAR distribution was investigated.
RESULTS: The EHD was approximately 1.4 cm and the EFS ranged between approximately 60 and approximately 300 cm(2), depending on the applicator type. Both measurements and simulations showed a split-up of the SAR focus with a 2 cm water bolus. The extent and location of air layers has a strong influence on the shape and size of the iso-SAR contours with a value higher than 50%, but the impact on EFS and EHD is limited.
CONCLUSION: Simulations, confirmed by measurements, showed that the presence of air between the rubber and the electrodes changes the iso-SAR contours, but the impact on the EFS and EHD is limited.

Entities:  

Mesh:

Year:  2009        PMID: 19657850     DOI: 10.1080/02656730903008493

Source DB:  PubMed          Journal:  Int J Hyperthermia        ISSN: 0265-6736            Impact factor:   3.914


  8 in total

1.  Effect of a combined surgery, re-irradiation and hyperthermia therapy on local control rate in radio-induced angiosarcoma of the chest wall.

Authors:  M Linthorst; A N van Geel; E A Baartman; S B Oei; W Ghidey; G C van Rhoon; J van der Zee
Journal:  Strahlenther Onkol       Date:  2013-04-04       Impact factor: 3.621

2.  Rib fractures after reirradiation plus hyperthermia for recurrent breast cancer: Predictive factors.

Authors:  Sabine Oldenborg; Christel Valk; Rob van Os; Bing Oei; Jack Venselaar; Paul Zum Vörde Sive Vörding; Adriënne van Randen; Hans Crezee; Geertjan van Tienhoven; Coen Rasch
Journal:  Strahlenther Onkol       Date:  2016-02-08       Impact factor: 3.621

3.  Thermal characteristics of thermobrachytherapy surface applicators for treating chest wall recurrence.

Authors:  K Arunachalam; P F Maccarini; O I Craciunescu; J L Schlorff; P R Stauffer
Journal:  Phys Med Biol       Date:  2010-03-12       Impact factor: 3.609

4.  Reirradiation + hyperthermia for recurrent breast cancer en cuirasse.

Authors:  Sabine Oldenborg; Coen R N Rasch; Rob van Os; Yoka H Kusumanto; Bing S Oei; Jack L Venselaar; Martijn W Heymans; Paul J Zum Vörde Sive Vörding; Hans Crezee; Geertjan van Tienhoven
Journal:  Strahlenther Onkol       Date:  2017-12-20       Impact factor: 3.621

Review 5.  Quality assurance guidelines for superficial hyperthermia clinical trials : II. Technical requirements for heating devices.

Authors:  Hana Dobšíček Trefná; Johannes Crezee; Manfred Schmidt; Dietmar Marder; Ulf Lamprecht; Michael Ehmann; Jacek Nadobny; Josefin Hartmann; Nicolleta Lomax; Sultan Abdel-Rahman; Sergio Curto; Akke Bakker; Mark D Hurwitz; Chris J Diederich; Paul R Stauffer; Gerard C Van Rhoon
Journal:  Strahlenther Onkol       Date:  2017-03-01       Impact factor: 3.621

6.  Impact of Technique and Schedule of Reirradiation Plus Hyperthermia on Outcome after Surgery for Patients with Recurrent Breast Cancer.

Authors:  Sabine Oldenborg; Rob van Os; Bing Oei; Philip Poortmans
Journal:  Cancers (Basel)       Date:  2019-06-05       Impact factor: 6.639

7.  Modelling Curved Contact Flexible Microstrip Applicators for Patient-Specific Superficial Hyperthermia Treatment Planning.

Authors:  H Petra Kok; Jort Groen; Akke Bakker; Johannes Crezee
Journal:  Cancers (Basel)       Date:  2020-03-11       Impact factor: 6.639

8.  Clinical Feasibility of a High-Resolution Thermal Monitoring Sheet for Superficial Hyperthermia in Breast Cancer Patients.

Authors:  Akke Bakker; Remko Zweije; Henny Petra Kok; Merel Willemijn Kolff; H J G Desiree van den Bongard; Manfred Schmidt; Geertjan van Tienhoven; Hans Crezee
Journal:  Cancers (Basel)       Date:  2020-12-04       Impact factor: 6.639

  8 in total