Literature DB >> 19652976

Comprehensive assessment of the severity and mechanism of aortic regurgitation using multidetector CT and MR.

Céline Goffinet1, Valérie Kersten, Anne-Catherine Pouleur, Jean-Benoit le Polain de Waroux, David Vancraeynest, Agnès Pasquet, Jean-Louis Vanoverschelde, Bernhard L Gerber.   

Abstract

Recent studies have suggested that both cardiac magnetic resonance (MR) and multidetector computed tomography (MDCT) can quantify aortic regurgitation (AR) by planimetry of the anatomical regurgitant orifice (ARO). However, this measurement was not compared with quantitative assessment of AR such as the effective regurgitant orifice (ERO) by proximal isosurface area (PISA) transthoracic echocardiography (TTE) or phase contrast MR. In 42 patients (34 men, age 54 +/- 11 years) we compared planimetered ARO by MDCT and MR with ERO and regurgitant volume by PISA TTE and phase contrast MR. ARO by MDCT (r = 0.87, p < 0.001) and MR (r = 0.81, p < 0.001) correlated highly with ERO by TTE. However, ARO by MDCT (27 +/- 15 mm(2), p < 0.001), but not by MR (23 +/- 13 mm(2), p = 0.58), were larger than PISA ERO (22 +/- 11 mm(2)). ARO by MDCT (r = 0.78, p < 0.001; r = 0.85, p < 0.001) and MR (r = 0.85, p < 0.001; r = 0.87 p < 0.001) correlated well with regurgitant volume by PISA and phase contrast MR. Both MDCT (small ka, Cyrillic = 0.80, p < 0.001) and MR (small ka, Cyrillic = 0.84, p < 0.001) demonstrated excellent agreement in correctly assessing the mechanisms of AR, i.e. aortic root dilatation (type I), cusp prolapse (type II) and restrictive cusp motion (type III), using surgical inspection as a reference. Measurement of ARO by both MDCT and MR allows accurate quantitative assessment of AR. Both techniques can also accurately determine the mechanism of AR.

Entities:  

Mesh:

Year:  2009        PMID: 19652976     DOI: 10.1007/s00330-009-1544-x

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  31 in total

Review 1.  Clinical practice. Aortic regurgitation.

Authors:  Maurice Enriquez-Sarano; A Jamil Tajik
Journal:  N Engl J Med       Date:  2004-10-07       Impact factor: 91.245

2.  Guidelines on the management of valvular heart disease: The Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology.

Authors:  Alec Vahanian; Helmut Baumgartner; Jeroen Bax; Eric Butchart; Robert Dion; Gerasimos Filippatos; Frank Flachskampf; Roger Hall; Bernard Iung; Jaroslaw Kasprzak; Patrick Nataf; Pilar Tornos; Lucia Torracca; Arnold Wenink
Journal:  Eur Heart J       Date:  2007-01-26       Impact factor: 29.983

3.  Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: meta-analysis.

Authors:  Piet K Vanhoenacker; Majanka H Heijenbrok-Kal; Ruben Van Heste; Isabel Decramer; Lieven R Van Hoe; William Wijns; M G Myriam Hunink
Journal:  Radiology       Date:  2007-08       Impact factor: 11.105

4.  A new method for quantification of regurgitant flow rate using color Doppler flow imaging of the flow convergence region proximal to a discrete orifice. An in vitro study.

Authors:  F Recusani; G S Bargiggia; A P Yoganathan; A Raisaro; L M Valdes-Cruz; H W Sung; C Bertucci; M Gallati; V A Moises; I A Simpson
Journal:  Circulation       Date:  1991-02       Impact factor: 29.690

5.  Functional anatomy of aortic regurgitation: accuracy, prediction of surgical repairability, and outcome implications of transesophageal echocardiography.

Authors:  Jean-Benoît le Polain de Waroux; Anne-Catherine Pouleur; Céline Goffinet; David Vancraeynest; Michel Van Dyck; Annie Robert; Bernhard L Gerber; Agnès Pasquet; Gébrine El Khoury; Jean-Louis J Vanoverschelde
Journal:  Circulation       Date:  2007-09-11       Impact factor: 29.690

Review 6.  Valvular heart disease: aortic regurgitation.

Authors:  Raffi Bekeredjian; Paul A Grayburn
Journal:  Circulation       Date:  2005-07-05       Impact factor: 29.690

7.  Severity of aortic regurgitation: interstudy reproducibility of measurements with velocity-encoded cine MR imaging.

Authors:  M C Dulce; G H Mostbeck; M O'Sullivan; M Cheitlin; G R Caputo; C B Higgins
Journal:  Radiology       Date:  1992-10       Impact factor: 11.105

8.  Precision of forty slice spiral computed tomography for quantifying aortic valve stenosis: comparison with echocardiography and validation against cardiac catheterization.

Authors:  Alexander Lembcke; Holger Thiele; André Lachnitt; Christian N H Enzweiler; Moritz Wagner; Patrick A Hein; Stephan Eddicks; Dietmar E Kivelitz
Journal:  Invest Radiol       Date:  2008-10       Impact factor: 6.016

9.  Planimetric and continuity equation assessment of aortic valve area: Head to head comparison between cardiac magnetic resonance and echocardiography.

Authors:  Anne-Catherine Pouleur; Jean-Benoît le Polain de Waroux; Agnès Pasquet; David Vancraeynest; Jean-Louis J Vanoverschelde; Bernhard L Gerber
Journal:  J Magn Reson Imaging       Date:  2007-12       Impact factor: 4.813

10.  Assessment of aortic regurgitation severity by magnetic resonance imaging of the thoracic aorta.

Authors:  P Ambrosi; G Faugère; L Desfossez; G Habib; M Bory; R Luccioni; P Bernard
Journal:  Eur Heart J       Date:  1995-03       Impact factor: 29.983

View more
  5 in total

1.  Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode.

Authors:  W Wuest; K Anders; A Schuhbaeck; M S May; S Gauss; M Marwan; M Arnold; S Ensminger; G Muschiol; W G Daniel; M Uder; S Achenbach
Journal:  Eur Radiol       Date:  2011-08-17       Impact factor: 5.315

2.  Planimetric measurement of the regurgitant orifice area using multidetector CT for aortic regurgitation: a comparison with the use of echocardiography.

Authors:  Min Hee Jeon; Yeon Hyeon Choe; Soo Jin Cho; Seung Woo Park; Pyo Won Park; Jae K Oh
Journal:  Korean J Radiol       Date:  2010-02-22       Impact factor: 3.500

3.  Quantitating aortic regurgitation by cardiovascular magnetic resonance: significant variations due to slice location and breath holding.

Authors:  Abhishek Chaturvedi; Christian Hamilton-Craig; Peter J Cawley; Lee M Mitsumori; Catherine M Otto; Jeffrey H Maki
Journal:  Eur Radiol       Date:  2015-12-03       Impact factor: 5.315

Review 4.  Evaluation of the aortic and mitral valves with cardiac computed tomography and cardiac magnetic resonance imaging.

Authors:  Sung Min Ko; Meong Gun Song; Hweung Kon Hwang
Journal:  Int J Cardiovasc Imaging       Date:  2012-11-09       Impact factor: 2.357

Review 5.  Multimodality Evaluation of Aortic Insufficiency and Aortitis in Rheumatologic Diseases.

Authors:  Eunjung Choi; Lena M Mathews; Julie Paik; Mary C Corretti; Katherine C Wu; Erin D Michos; Allison G Hays; Monica Mukherjee
Journal:  Front Cardiovasc Med       Date:  2022-04-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.