Literature DB >> 1965228

[Clinical evaluation of lung scintigraphy with 99mTc-technegas].

T Inoue1, N Watanabe, N Oriuchi, M Tateno, K Tomiyoshi, O Mitomo, K Hayakawa, H Niibe, Y Sasaki.   

Abstract

The aim of this study is to evaluate the safety and clinical usefulness of lung scintigraphy using 99mTc-technegas produced by the evaporation of pertechnetate elution at 2500 degrees C. Lung images were recorded by the gamma camera-computer system after a few deep inspirations of 99mTc-technegas. One healthy volunteer and 32 patients including 10 with lung cancer, 8 with chronic obstructive lung disease, 5 with pulmonary embolism, 2 with interstitial pneumonia, 2 with bronchiectasis and 12 with other various disease were studied. Delayed images were taken at more than 1 hour later in one healthy and 13 patients to investigate the interval changes of the intrapulmonary distribution of 99mTc-technegas. Obvious differences of radioactive distribution between early and delayed image were observed in only 2/14 cases. Penetration index (P.I.) averaged 0.81 +/- 0.11 for early images and 0.85 +/- 0.12 for delayed image. There was no significant difference between P.I. for early and delayed images. More than 97 MBq of 99mTc-macroaggregated albumin (99mTc-MAA) were required to obtain the adequate perfusion images after the acquisition of lung images with about 37 MBq of 99mTc-technegas. Bronchial deposits of 99mTc-technegas were shown in 12/33 cases and pathological defects in 26/32 patients (81.3%). Twenty three of 33 cases also had a perfusion scintigraphy with 99mTc-MAA. Ventilation perfusion mismatches were presented in 5/5 patients with pulmonary embolism and 1/10 patients with lung cancer. The safety was confirmed in all cases and clinical usefulness in 30/32 patients (94%). In conclusion, the safety and clinical usefulness of lung scintigraphy with 99mTc-technegas were proven in this study.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 1965228

Source DB:  PubMed          Journal:  Nihon Igaku Hoshasen Gakkai Zasshi        ISSN: 0048-0428


  3 in total

1.  EANM guidelines for ventilation/perfusion scintigraphy : Part 1. Pulmonary imaging with ventilation/perfusion single photon emission tomography.

Authors:  M Bajc; J B Neilly; M Miniati; C Schuemichen; M Meignan; B Jonson
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-08       Impact factor: 9.236

2.  Ventilation/Perfusion SPECT for Diagnosis of Pulmonary Embolism and Other Diseases.

Authors:  Marika Bajc; Björn Jonson
Journal:  Int J Mol Imaging       Date:  2010-12-19

3.  Comparison of 81mKrypton and 99mTc-Technegas for ventilation single-photon emission computed tomography in severe chronic obstructive pulmonary disease.

Authors:  Robin de Nijs; Nienke D Sijtsema; Matthijs F Kruis; Claus Verner Jensen; Martin Iversen; Michael Perch; Jann Mortensen
Journal:  Nucl Med Commun       Date:  2021-02-01       Impact factor: 1.698

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.