Literature DB >> 19651352

Effect of screw diameter on orthodontic skeletal anchorage.

Chad Morarend1, Fang Qian, Steve D Marshall, Karin A Southard, Nicole M Grosland, Teresa A Morgan, Michelle McManus, Thomas E Southard.   

Abstract

INTRODUCTION: Many case reports have documented the successful use of titanium miniscrews for orthodontic anchorage. However, the literature lacks a well-controlled study examining the effect of miniscrew diameter on anchorage force resistance. The purpose of this in-vitro study was to compare the force resistance of larger-diameter monocortical miniscrews to smaller-diameter monocortical miniscrews; and to compare the force resistance of larger-diameter monocortical miniscrews to smaller-diameter bicortical miniscrews.
METHODS: Ninety-six titanium alloy screws were placed into 24 hemisected maxillary and 24 hemisected mandibular specimens between the first and second premolars. Specimens were randomly and evenly divided into 2 groups. In the first group, 24 large-diameter screws (2.5 x 17 mm) and with 24 small-diameter screws (1.5 x 15 mm) were placed monocortically. In the second group, 24 large-diameter screws (2.5 x 17 mm) were placed monocortically and 24 small-diameter screws (1.5 x 15 mm) were placed bicortically. All screws were subjected to tangential force loading perpendicular to the miniscrew with lateral displacement of 0.6 mm. Statistical analyses, including the paired-samples t test and the 2-samples t test, were used to quantify screw force-deflection characteristics. One-way analysis of variance (ANOVA) with the post-hoc Tukey studentized range test was used to determine any significant differences, and the order of those differences, in force anchorage values among the 3 screw types at maxillary and mandibular sites.
RESULTS: Mean mandibular and maxillary anchorage force values of the 2.5-mm monocortical screws were significantly greater than those of the 1.5-mm monocortical screws (P <0.01). No statistically significant differences in mean mandibular anchorage force values were found between the 2.5-mm monocortical screws and the 1.5-mm bicortical screws. However, mean maxillary anchorage force values of the 1.5-mm bicortical screws were significantly greater than those of the 2.5-mm monocortical screws (P <0.01). Data analyzed with 1-way ANOVA with the post-hoc Tukey studentized range tests indicated that the mean mandibular and maxillary force values of the 2.5-mm monocortical screws and the 1.5-mm bicortical screws were significantly greater than those of the 1.5-mm monocortical screws (P <0.01). Based on the 2-samples t test, mean anchorage force values at mandibular sites were significantly greater than at maxillary sites for the 2.5-mm monocortical screws and the 1.5-mm monocortical screws. There were no statistically significant differences in mean anchorage force values between maxillary and mandibular sites for the 1.5-mm bicortical screws.
CONCLUSIONS: In vitro, larger-diameter (2.5 mm) monocortical screws provide greater anchorage force resistance than do smaller-diameter (1.5 mm) monocortical screws in both the mandible and the maxilla. Smaller-diameter (1.5 mm) bicortical screws provide anchorage force resistance at least equal to larger-diameter (2.5 mm) monocortical screws. An alternative to placing a larger-diameter miniscrew for additional anchorage is a narrower bicortical screw.

Mesh:

Year:  2009        PMID: 19651352     DOI: 10.1016/j.ajodo.2007.07.031

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  10 in total

1.  Evaluation of miniscrew stability using an automatic embedding auxiliary skeletal anchorage device.

Authors:  Yasuhiko Oga; Hiroshi Tomonari; Sangho Kwon; Takaharu Kuninori; Takakazu Yagi; Shouichi Miyawaki
Journal:  Angle Orthod       Date:  2018-09-01       Impact factor: 2.079

2.  Direct versus indirect loading of orthodontic miniscrew implants-an FEM analysis.

Authors:  C Holberg; P Winterhalder; N Holberg; I Rudzki-Janson; A Wichelhaus
Journal:  Clin Oral Investig       Date:  2012-10-31       Impact factor: 3.573

3.  Indirect miniscrew anchorage: biomechanical loading of the dental anchorage during mandibular molar protraction-an FEM analysis.

Authors:  Christof Holberg; Philipp Winterhalder; Nikola Holberg; Andrea Wichelhaus; Ingrid Rudzki-Janson
Journal:  J Orofac Orthop       Date:  2014-01-23       Impact factor: 1.938

4.  Factors affecting stresses in cortical bone around miniscrew implants: a three-dimensional finite element study.

Authors:  Ramzi Duaibis; Budi Kusnoto; Raghu Natarajan; Linping Zhao; Carla Evans
Journal:  Angle Orthod       Date:  2012-03-05       Impact factor: 2.079

5.  Effects of screw and host factors on insertion torque and pullout strength.

Authors:  Ankit H Shah; Rolf G Behrents; Ki Beom Kim; Hee-Moon Kyung; Peter H Buschang
Journal:  Angle Orthod       Date:  2012-07       Impact factor: 2.079

Review 6.  Systematic review of mini-implant displacement under orthodontic loading.

Authors:  Manuel Nienkemper; Jörg Handschel; Dieter Drescher
Journal:  Int J Oral Sci       Date:  2013-12-20       Impact factor: 6.344

7.  Fracture strength of orthodontic mini-implants.

Authors:  Tatiana Feres Assad-Loss; Flávia Mitiko Fernandes Kitahara-Céia; Giordani Santos Silveira; Carlos Nelson Elias; José Nelson Mucha
Journal:  Dental Press J Orthod       Date:  2017 May-Jun

8.  Influence of interradicular and palatal placement of orthodontic mini-implants on the success (survival) rate.

Authors:  Jan Hourfar; Dirk Bister; Georgios Kanavakis; Jörg Alexander Lisson; Björn Ludwig
Journal:  Head Face Med       Date:  2017-06-14       Impact factor: 2.151

9.  Reliability of Orthodontic Miniscrews: Bending and Maximum Load of Different Ti-6Al-4V Titanium and Stainless Steel Temporary Anchorage Devices (TADs).

Authors:  Andrea Scribante; Mona A Montasser; Eman Saad Radwan; Luisa Bernardinelli; Roberto Alcozer; Paola Gandini; Maria Francesca Sfondrini
Journal:  Materials (Basel)       Date:  2018-07-05       Impact factor: 3.623

10.  Effects of a newly designed apparatus on orthodontic skeletal anchorage.

Authors:  Murat Tozlu; Didem Nalbantgil; Fulya Ozdemir
Journal:  Eur J Dent       Date:  2013-09
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.