Time delay of electroencephalogram index calculation: analysis of cerebral state, bispectral, and Narcotrend indices using perioperatively recorded electroencephalographic signals.

R Zanner1, S Pilge, E F Kochs, M Kreuzer, G Schneider.   

Abstract

BACKGROUND: Monitoring of anaesthetic depth with EEG-derived indices may detect EEG changes associated with awareness and thereby help to decrease the incidence of intraoperative awareness with postoperative recall. All currently available monitors need varying time periods to calculate a new index when reacting to changes in anaesthetic depth. The exact time delay for calculation of new index values is unknown. In a previous study, we used simulated EEG signals and found considerable time lags for the cerebral state index (Danmeter, Odense, Denmark), the bispectral index (Aspect Medical Systems Inc., Newton, MA, USA), and the Narcotrend index (MonitorTechnik, Bad Bramstedt, Germany). The aim of this study was to investigate whether the time delays observed with simulated EEG signals also applied to real EEG data.
METHODS: We used perioperatively recorded EEG data from a database corresponding to the awake state, general anaesthesia, and suppression of cortical activity, respectively. After a switch from one state of consciousness to another, the time necessary for all indices to adjust the index value to the underlying input signal was measured.
RESULTS: We found time delays for all indices between 24 (7) and 122 (23) s before the new state was indicated. In accordance with our previous results, these time delays were not constant and depended on the particular starting and target index value. Results were different for decreasing and increasing values.
CONCLUSIONS: Our results may show a limitation of the value of electronic EEG indices in prevention of awareness with recall. Furthermore, due to different time delays for ascending and descending values, the results of pharmacodynamic studies may be influenced by this phenomenon.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19648154     DOI: 10.1093/bja/aep198

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  22 in total

1.  Index of consciousness and bispectral index values are interchangeable during normotension and hypotension but not during non pulsatile flow state during cardiac surgical procedures: a prospective study.

Authors:  Murali Chakravarthy; Srinivasa Holla; Vivek Jawali
Journal:  J Clin Monit Comput       Date:  2009-12-10       Impact factor: 2.502

Review 2.  Automation of anaesthesia: a review on multivariable control.

Authors:  Jing Jing Chang; S Syafiie; Raja Kamil; Thiam Aun Lim
Journal:  J Clin Monit Comput       Date:  2014-06-25       Impact factor: 2.502

3.  Non-stationarity of EEG during wakefulness and anaesthesia: advantages of EEG permutation entropy monitoring.

Authors:  Matthias Kreuzer; Eberhard F Kochs; Gerhard Schneider; Denis Jordan
Journal:  J Clin Monit Comput       Date:  2014-01-18       Impact factor: 2.502

4.  Spectral and Entropic Features Are Altered by Age in the Electroencephalogram in Patients under Sevoflurane Anesthesia.

Authors:  Matthias Kreuzer; Matthew A Stern; Darren Hight; Sebastian Berger; Gerhard Schneider; James W Sleigh; Paul S García
Journal:  Anesthesiology       Date:  2020-05       Impact factor: 7.892

5.  Brain Monitoring of Sedation in the Intensive Care Unit Using a Recurrent Neural Network.

Authors:  Haoqi Sun; Sunil B Nagaraj; Oluwaseun Akeju; Patrick L Purdon; Brandon M Westover
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2018-07

6.  Robust control of burst suppression for medical coma.

Authors:  M Brandon Westover; Seong-Eun Kim; ShiNung Ching; Patrick L Purdon; Emery N Brown
Journal:  J Neural Eng       Date:  2015-05-28       Impact factor: 5.379

Review 7.  Brain monitoring with electroencephalography and the electroencephalogram-derived bispectral index during cardiac surgery.

Authors:  Miklos D Kertai; Elizabeth L Whitlock; Michael S Avidan
Journal:  Anesth Analg       Date:  2012-01-17       Impact factor: 5.108

8.  Suitable dental sedation monitored by electroencephalographic density spectral array: A case report and review of literature.

Authors:  Wei-Hsiu Huang; Yu-Pin Feng; Chung-Tzu Hsueh
Journal:  J Dent Sci       Date:  2022-03-16       Impact factor: 3.719

9.  Depth of general anaesthesia monitors.

Authors:  D Devika Rani; Ss Harsoor
Journal:  Indian J Anaesth       Date:  2012-09

Review 10.  Monitoring the depth of anaesthesia.

Authors:  Bojan Musizza; Samo Ribaric
Journal:  Sensors (Basel)       Date:  2010-12-03       Impact factor: 3.576