Literature DB >> 19635834

Crohn disease: correlation of findings at contrast-enhanced US with severity at endoscopy.

Tomás Ripollés1, María J Martínez, Jose M Paredes, Esther Blanc, Lucía Flors, Fructuoso Delgado.   

Abstract

PURPOSE: To evaluate the effectiveness of visualization of vascularization at contrast material-enhanced ultrasonography (US) for assessment of the activity of Crohn disease, with severity grade determined at endoscopy as the reference standard.
MATERIALS AND METHODS: Ethics committee approval and written informed consent were obtained. Sixty-one patients (age range, 21-67 years; median age, 36 years) who had Crohn disease underwent both colonoscopy and US, including color Doppler and contrast-enhanced US, prospectively. To assess the vascularization of the involved bowel loop in a region expected to be seen at colonoscopy, the contrast agent uptake was measured by using quantitative analysis of the enhancement in regions of interest. Measurement of contrast enhancement was assessed as the increase in wall brightness with respect to the baseline brightness. Results were compared with the severity grade determined at endoscopy by using the area under the receiver operating characteristic curve and logistic regression analysis.
RESULTS: Colonoscopy showed inflammatory lesions in 53 patients (mild disease, seven; moderate disease, 12; and severe disease, 34). Bowel wall thickness and grade at color Doppler US (P = .019 and .002, respectively) correlated with severity grade at endoscopy. Mural contrast enhancement in patients with active disease at endoscopy was markedly increased in comparison with enhancement in patients with inactive disease (P < .001). Multivariate logistic regression analysis revealed that an increase in wall brightness was a significant and independent variable predictive of severity grade at endoscopy. A threshold brightness value of percentage of increase of 46% had a sensitivity and specificity of 96% and 73%, respectively, in the prediction of moderate or severe grade for inflammation at endoscopy.
CONCLUSION: Quantitative measurements of bowel enhancement obtained by using contrast-enhanced US correlate with severity grade determined at endoscopy. Contrast-enhanced US could be a useful technique to monitor the activity of Crohn disease. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2531082269/-/DC1.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19635834     DOI: 10.1148/radiol.2531082269

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  36 in total

1.  Contrast-enhanced ultrasound: The evolving applications.

Authors:  Hui-Xiong Xu
Journal:  World J Radiol       Date:  2009-12-31

Review 2.  Ultrasound features of pediatric Crohn disease: a guide for case interpretation.

Authors:  David M Biko; Daniel G Rosenbaum; Sudha A Anupindi
Journal:  Pediatr Radiol       Date:  2015-07-12

3.  Conventional ultrasound and contrast-enhanced ultrasound in evaluating the severity of Crohn's disease.

Authors:  Chang Liu; Xiao-Rong Xu; Hui-Xiong Xu; Zhan-Ju Liu; Yi-Feng Zhang; Li-Ping Sun; Jun-Mei Xu; Lin-Na Liu; Le-Hang Guo; Xiao-Wan Bo
Journal:  Int J Clin Exp Med       Date:  2015-01-15

Review 4.  Ultrasound findings of Crohn's disease: correlation with MR enterography.

Authors:  Estefania Gonzalez-Montpetit; Tomás Ripollés; María J Martinez-Pérez; José Vizuete; Gregorio Martín; Esther Blanc
Journal:  Abdom Radiol (NY)       Date:  2020-06-30

Review 5.  SICUS and CEUS imaging in Crohn's disease: an update.

Authors:  Giammarco Mocci; Vincenzo Migaleddu; Francesco Cabras; Danilo Sirigu; Domenico Scanu; Giuseppe Virgilio; Manuela Marzo
Journal:  J Ultrasound       Date:  2017-01-02

Review 6.  Chronic inflammatory diseases of the bowel: diagnosis and follow-up.

Authors:  Guillaume Gorincour; Audrey Aschero; Catherine Desvignes; François Portier; Brigitte Bourlière-Najean; Alix Ruocco-Angari; Philippe Devred; Nathalie Colavolpe; Bertrand Roquelaure; Arnaud Delarue; Philippe Petit
Journal:  Pediatr Radiol       Date:  2010-04-30

Review 7.  Diagnostics in inflammatory bowel disease: ultrasound.

Authors:  Deike Strobel; Ruediger S Goertz; Thomas Bernatik
Journal:  World J Gastroenterol       Date:  2011-07-21       Impact factor: 5.742

8.  Assessment of angiogenesis in rabbit orthotropic liver tumors using three-dimensional dynamic contrast-enhanced ultrasound compared with two-dimensional DCE-US.

Authors:  Qiao Zheng; Jian-Chao Zhang; Zhu Wang; Si-Min Ruan; Wei Li; Fu-Shun Pan; Li-Da Chen; Yu-Chen Zhang; Wen-Xin Wu; Xiao-Yan Xie; Ming-De Lu; Quan-Yuan Shan; Wei Wang
Journal:  Jpn J Radiol       Date:  2019-08-10       Impact factor: 2.374

9.  Intravenous Contrast-Enhanced Ultrasound for Assessing and Grading Postoperative Recurrence of Crohn's Disease.

Authors:  María Jesús Martínez; Tomás Ripollés; Jose María Paredes; Eduardo Moreno-Osset; Juan Manuel Pazos; Esther Blanc
Journal:  Dig Dis Sci       Date:  2019-01-02       Impact factor: 3.199

10.  Positioning Ultrasonography Into Clinical Practice for the Management of Crohn's Disease.

Authors:  Emma Calabrese; Francesca Zorzi; Elisabetta Lolli; Francesco Pallone
Journal:  Gastroenterol Hepatol (N Y)       Date:  2015-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.