Literature DB >> 19631132

Intraocular pressure changes during injection of microincision and conventional intraocular lenses through incisions smaller than 3.0 mm.

Kandon K Kamae1, Liliana Werner, Wellington Chang, Jonathan T Johnson, Nick Mamalis.   

Abstract

PURPOSE: To compare intraocular pressure (IOP) during insertion of a new microincision intraocular lens (IOL) (Akreos AO MI60) and a conventional IOL (AcrySof Natural SN60AT) and to determine the minimum incision sizes for insertion in a cadaver eye model.
SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA.
METHODS: After phacoemulsification in phakic cadaver eyes, multiple IOL insertions were attempted through 1.8 mm to 2.5 mm wounds. The final incision size and insertion success were evaluated in each case. A pressure transducer placed in the vitreous cavity measured real-time IOP changes (100 readings per second), including the mean and peak IOP during IOL implantation.
RESULTS: The minimum incision size for the microincision IOL insertion was 1.9 mm using a wound-assisted technique and 2.2 mm using a cartridge-insertion technique. The minimum incision size for wound-assisted implantation of the conventional IOL was 2.4 mm. During successful implantation, the mean and peak IOPs were similar between the 2 IOL types. The peak IOPs exceeded 60 mm Hg (retinal perfusion pressure). In unsuccessful attempts, the mean and peak IOPs were higher for the conventional IOL, reaching 306.05 mm Hg in 1 eye.
CONCLUSIONS: Monitoring during implantation of both IOL types confirmed that IOP increases during insertion, including during microincision surgery using a wound-assisted technique. Further studies are necessary to evaluate the effect of pressure spikes on the optic nerve during IOL insertion.

Mesh:

Year:  2009        PMID: 19631132     DOI: 10.1016/j.jcrs.2009.03.038

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  4 in total

1.  Air pressure changes in the creation and bursting of the type-1 big bubble in deep anterior lamellar keratoplasty: an ex vivo study.

Authors:  S L AlTaan; I Mohammed; D G Said; H S Dua
Journal:  Eye (Lond)       Date:  2017-06-30       Impact factor: 3.775

Review 2.  An examination of the hypothesis that intraocular pressure elevation episodes can have prognostic significance in glaucoma suspects.

Authors:  Charles McMonnies
Journal:  J Optom       Date:  2014-09-04

3.  Injection time related to intraocular pressure using a CO2 driven preloaded injector: An experimental laboratory study.

Authors:  Jan N Weindler; Tadas Naujokaitis; Sonja K Schickhardt; Ramin Khoramnia; Gerd U Auffarth
Journal:  PLoS One       Date:  2021-07-19       Impact factor: 3.240

4.  Transient ocular surface non-perfusion during cataract phacoemulsification surgery.

Authors:  Yijun Hu; Wei Qi; Baoyi Liu; Honghua Yu
Journal:  BMC Ophthalmol       Date:  2020-07-31       Impact factor: 2.209

  4 in total