Literature DB >> 19628450

Passive spatial mapping of inertial cavitation during HIFU exposure.

Miklós Gyöngy1, Constantin-C Coussios.   

Abstract

A novel method for mapping inertial cavitation activity during high-intensity focused ultrasound (HIFU) exposure is presented. Inertial cavitation has been previously shown to result in increased heat deposition and to be associated with broadband noise emissions that can be readily monitored using a passive receiver without interference from the main HIFU signal. In the present study, the signals received passively by each of 64 elements on a standard diagnostic array placed coaxially with the HIFU transducer are combined using time exposure acoustics to generate maps of inertially cavitating regions during HIFU exposure of an agar-based tissue-mimicking material. The technique is shown to be effective in localizing single-bubble activity, as well as contiguous and disjoint cavitating regions instigated by creating regions of lower cavitation threshold within the tissue phantom. The cavitation maps obtained experimentally are also found to be in good agreement with computational simulations and theoretical predictions. Unlike B-mode imaging, which requires interleaving with the HIFU pulse, passive array-based mapping of cavitation activity is possible during HIFU exposure. If cavitating regions can be directly correlated to increased tissue damage, this novel cavitation mapping technique could enable real-time HIFU treatment monitoring.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19628450     DOI: 10.1109/TBME.2009.2026907

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  57 in total

1.  Passive imaging with pulsed ultrasound insonations.

Authors:  Kevin J Haworth; T Douglas Mast; Kirthi Radhakrishnan; Mark T Burgess; Jonathan A Kopechek; Shao-Ling Huang; David D McPherson; Christy K Holland
Journal:  J Acoust Soc Am       Date:  2012-07       Impact factor: 1.840

2.  Integrated ultrasound and magnetic resonance imaging for simultaneous temperature and cavitation monitoring during focused ultrasound therapies.

Authors:  Costas D Arvanitis; Nathan McDannold
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

3.  A super-resolution ultrasound method for brain vascular mapping.

Authors:  Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

Review 4.  MR-guided focused ultrasound surgery, present and future.

Authors:  David Schlesinger; Stanley Benedict; Chris Diederich; Wladyslaw Gedroyc; Alexander Klibanov; James Larner
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

5.  Three-dimensional transcranial ultrasound imaging of microbubble clouds using a sparse hemispherical array.

Authors:  Meaghan A O'Reilly; Ryan M Jones; Kullervo Hynynen
Journal:  IEEE Trans Biomed Eng       Date:  2014-04       Impact factor: 4.538

6.  Combined passive detection and ultrafast active imaging of cavitation events induced by short pulses of high-intensity ultrasound.

Authors:  Jérôme Gateau; Jean-François Aubry; Mathieu Pernot; Mathias Fink; Mickaël Tanter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-03       Impact factor: 2.725

7.  Experimental demonstration of passive acoustic imaging in the human skull cavity using CT-based aberration corrections.

Authors:  Ryan M Jones; Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

Review 8.  Advances in acoustic monitoring and control of focused ultrasound-mediated increases in blood-brain barrier permeability.

Authors:  Ryan M Jones; Kullervo Hynynen
Journal:  Br J Radiol       Date:  2019-02-28       Impact factor: 3.039

9.  Visualizing the movement of the contact between vocal folds during vibration by using array-based transmission ultrasonic glottography.

Authors:  Bowen Jing; Pengju Chigan; Zhengtong Ge; Liang Wu; Supin Wang; Mingxi Wan
Journal:  J Acoust Soc Am       Date:  2017-05       Impact factor: 1.840

Review 10.  Focused Ultrasound for Neuromodulation.

Authors:  David P Darrow
Journal:  Neurotherapeutics       Date:  2019-01       Impact factor: 7.620

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.