| Literature DB >> 19624850 |
Bernhard Thielen1, Stephanie Heinen, Dietmar Schomburg.
Abstract
BACKGROUND: Metabolome analysis with GC/MS has meanwhile been established as one of the "omics" techniques. Compound identification is done by comparison of the MS data with compound libraries. Mass spectral libraries in the field of metabolomics ought to connect the relevant mass traces of the metabolites to other relevant data, e.g. formulas, chemical structures, identification numbers to other databases etc. Since existing solutions are either commercial and therefore only available for certain instruments or not capable of storing such information, there is need to provide a software tool for the management of such data.Entities:
Mesh:
Year: 2009 PMID: 19624850 PMCID: PMC2731052 DOI: 10.1186/1471-2105-10-229
Source DB: PubMed Journal: BMC Bioinformatics ISSN: 1471-2105 Impact factor: 3.169
Figure 1A screenshot of the graphical user interface of mSpecs. The specifications page showing a list of entries (left) and the data fields for the chosen compound (N, N, O-Tris-(trimethylsilyl)alanine; right).
Available data fields, their type and whether they are sortable or filterable.
| ID | string | identification number | yes/yes |
| Name | string | identifier | yes/yes |
| Molecular weight | double | molecular weight | yes/yes |
| Formula | string | chemical formula | no/yes |
| IUPAC-name | string | IUPAC-name | no/yes |
| SMILES | string | SMILES-code [ | no/yes |
| InChI | string | InChI-code [ | no/yes |
| Identification numbers | 2D array1) | e.g. KEGG compound number [ | no/yes |
| Synonyms | array of strings | synonyms | no/yes |
| ID | string | identification number | yes/yes |
| Derivative | string | identifier | yes/yes |
| Monoisotopic mass | double | monoisotopic mass [ | yes/yes |
| Retention time (min) | double | Retention time | yes/yes |
| Retention index | double | Kováts retention index [ | yes/yes |
| RI positive drift | double | Positive drift of retention index | yes/yes |
| RI negative drift | double | Negative drift of retention index | yes/yes |
| Alkanes | 2D array1) | reference list of alkanes | no/no |
| Mass traces | array of doubles | list of reference ions for quantification | no/yes |
| Comment | string | commentaries | no/yes |
| Component | molecule2) | chemical structure of the component | no/no |
| Derivative | molecule2) | chemical structure of the derivative | no/no |
| Visual representation | -- | graphical representation | no/no |
| Tabular representation | 2D array1) | tabular representation | no/no |
| Author | string | author of the measurement | no/yes |
| Date | date | date of measurement | yes/yes |
| Device | string | device used | no/yes |
| Method | string | explanation to the method | no/yes |
| Column | string | used chromatographic column | no/yes |
| Experimental conditions | string | further experimental conditions | no/yes |
| Reactions | array of strings | associated reactions | no/yes |
| Enzymes | 2D array1) | associated enzymes | no/yes |
| Genes | 2D array1) | associated genes | no/yes |
1) Table with a given number of columns and arbitrary number of rows.
2) Object storing a molecular structure.