Literature DB >> 19620015

Evaluation criteria for film based intensity modulated radiation therapy quality assurance.

Muhammad Naeem Anjum1, William Parker, Russell Ruo, Muhammad Afzal.   

Abstract

The aim of this study was to use different gamma histogram criteria for the comparison of planned dose with irradiated dose distribution and find that what percent of pixels passing a certain criteria imitate a good quality plan. The dose was calculated for 156 patients by inverse planning optimization using the Corvus treatment planning system. Gafchromic films in combination with 2571 0.6 cm(3) Farmer type ionization chamber and Farmer 2570/1 electrometer from NE Technology were used to measure the delivered dose in solid water phantom. All the measurements were performed on Varian CL21EX linear accelerator (Varian Medical Systems, Palo Alto, CA) fitted with a Millennium 120 leaf collimator. In this study the mean value of the percent of passing pixels within the region of interest under the criterion of 3% DD and 3mm DTA is 90.2+/-7.1% for head and neck cases and 92.2+/-5.8% for non-head and neck cases. If we choose the criteria of 3% DD and 3mm DTA then 96.3% head and neck plans have the percent of passing pixels>or=75% and 95.1% non-head and neck plans have the percent of passing pixels>or=80%. It is evident from the results of this study that the criterion of 5% DD and 3mm DTA with the percent of passing pixels>or=90 for non-head and neck cases while the percent of passing pixels>or=85 for head and neck cases endorse that a plan is good. The results of this study may be useful for other institutions which use verification software and EBT films for patient specific IMRT QA. Copyright 2009 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19620015     DOI: 10.1016/j.ejmp.2009.06.002

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  5 in total

1.  Anatomy-corresponding method of IMRT verification.

Authors:  Janusz Winiecki; Zbigniew Zurawski; Barbara Drzewiecka; Krzysztof Slosarek
Journal:  Rep Pract Oncol Radiother       Date:  2010-12-04

2.  Homogeneity of GAFCHROMIC EBT2 film among different lot numbers.

Authors:  Hirokazu Mizuno; Yutaka Takahashi; Atsushi Tanaka; Takamitsu Hirayama; Tsuyoshi Yamaguchi; Hiroaki Katou; Keiko Takahara; Yoshiaki Okamoto; Teruki Teshima
Journal:  J Appl Clin Med Phys       Date:  2012-07-05       Impact factor: 2.102

3.  Absolute dose verification of static intensity modulated radiation therapy (IMRT) with ion chambers of various volumes and TLD detectors.

Authors:  Hediye Acun-Bucht; Ebru Tuncay; Emin Darendeliler; Gönül Kemikler
Journal:  Rep Pract Oncol Radiother       Date:  2018-05-19

4.  On flattening filter-free portal dosimetry.

Authors:  Eduardo Pardo; Juan Castro Novais; María Yolanda Molina López; Sheila Ruiz Maqueda
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

5.  MRI-based radiotherapy planning method using rigid image registration technique combined with outer body correction scheme: a feasibility study.

Authors:  Ki Mun Kang; Hoon Sik Choi; Bae Kwon Jeong; Jin Ho Song; In-Bong Ha; Yun Hee Lee; Chul Hang Kim; Hojin Jeong
Journal:  Oncotarget       Date:  2017-05-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.