Literature DB >> 19619844

Comparison of GFR measurements assessed from single versus multiple samples.

Nicholas J Bird1, Christina Peters, A Robert Michell, A Michael Peters.   

Abstract

BACKGROUND: Many previous studies have evaluated single-sample glomerular filtration rate (GFR) against multisample GFR, of which the single sample was a member, but none have compared single and multisample GFRs against an independent reference method. We therefore performed this comparison by using simultaneous independent multisample GFR measured with a different indicator. SETTING & PARTICIPANTS: University hospital: patients and healthy volunteers (95 studies in 60 patients and 20 healthy participants). Healthy volunteers were studied fasting and after food; 10 of them had a repeated fasting study. STUDY
DESIGN: Diagnostic test study. INDEX TEST: Single-sample GFR. REFERENCE TEST: Multisample GFR with a different indicator. MEASUREMENTS: GFR was measured by using chromium-51 ((51)Cr)-EDTA and iohexol, injected into opposite arms and scaled to 1.73 m(2). Blood samples, obtained bilaterally 20, 40, 60, 120, 180, and 240 minutes after injection, were assayed for indicator injected contralaterally. Single-sample GFR (Jacobsson method) was calculated from indicator concentrations at 3 and 4 hours. Single-sample GFR from 1 indicator was compared with multisample GFR from the other and vice versa, as well as from the same indicator. Differences were expressed as limits of agreement between paired measurements in Bland-Altman plots. Precision was expressed as the SD of the mean difference between paired measurements.
RESULTS: Limits of agreement between multisample GFRs measured by using (51)Cr-EDTA and iohexol (-12 to 20 mL/min) were similar to the corresponding limits for single-sample GFR at 3 (-16 to 17 mL/min) and 4 hours (-11 to 17 mL/min). The precision of single-sample GFR at 4 hours by using (51)Cr-EDTA for predicting iohexol multisample GFR (6.9 mL/min) was better than that of multisample GFR with (51)Cr-EDTA (7.9 mL/min). When analysis was limited to patients with GFR less than 60 mL/min, single-sample GFR was slightly inferior to multisample GFR. In healthy participants, single-sample GFR with (51)Cr-EDTA at 3 and 4 hours showed repeatability (SD of change, 9.4 and 9.3 mL/min) similar to multisample GFR with (51)Cr-EDTA (10.7 mL/min). Single-sample GFR at 4 hours by using (51)Cr-EDTA detected a food-induced increase in GFR (4.4 +/- 5.9 mL/min; P < 0.001) with more confidence than multisample GFR by using (51)Cr-EDTA (4.6 +/- 7.5 mL/min; P < 0.01). LIMITATIONS: No separate gold standard (eg, inulin) to facilitate interpretation of observed differences between 2 markers.
CONCLUSIONS: Single-sample GFR is as reliable as multisample GFR for measuring GFR, especially when GFR is greater than 60 mL/min.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19619844     DOI: 10.1053/j.ajkd.2009.03.026

Source DB:  PubMed          Journal:  Am J Kidney Dis        ISSN: 0272-6386            Impact factor:   8.860


  14 in total

1.  Association of TNF Receptor 2 and CRP with GFR Decline in the General Nondiabetic Population.

Authors:  Jørgen Schei; Vidar Tor Nyborg Stefansson; Bjørn Odvar Eriksen; Trond Geir Jenssen; Marit Dahl Solbu; Tom Wilsgaard; Toralf Melsom
Journal:  Clin J Am Soc Nephrol       Date:  2017-02-02       Impact factor: 8.237

2.  GFR normalized to total body water allows comparisons across genders and body sizes.

Authors:  Bjørn O Eriksen; Toralf Melsom; Ulla D Mathisen; Trond G Jenssen; Marit D Solbu; Ingrid Toft
Journal:  J Am Soc Nephrol       Date:  2011-07-22       Impact factor: 10.121

3.  Universal GFR determination based on two time points during plasma iohexol disappearance.

Authors:  Derek K S Ng; George J Schwartz; Lisa P Jacobson; Frank J Palella; Joseph B Margolick; Bradley A Warady; Susan L Furth; Alvaro Muñoz
Journal:  Kidney Int       Date:  2011-06-08       Impact factor: 10.612

4.  Estimated GFR associates with cardiovascular risk factors independently of measured GFR.

Authors:  Ulla Dorte Mathisen; Toralf Melsom; Ole C Ingebretsen; Trond Jenssen; Inger Njølstad; Marit D Solbu; Ingrid Toft; Bjørn O Eriksen
Journal:  J Am Soc Nephrol       Date:  2011-03-31       Impact factor: 10.121

5.  The reliability of glomerular filtration rate measured from plasma clearance: a multi-centre study of 1,878 healthy potential renal transplant donors.

Authors:  A Michael Peters; Bethany Howard; Mark D J Neilly; Nagabhushan Seshadri; Ravin Sobnack; Claire A Hooker; Andrew Irwin; Hayley Snelling; Thomas Gruning; Laura Perry; Neva H Patel; Richard S Lawson; Gregory Shabo; Nigel Williams; Surendra Dave; Mark C Barnfield
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-01-06       Impact factor: 9.236

6.  An efficient approach for glomerular filtration rate assessment in older adults.

Authors:  Peter Martus; Natalie Ebert; Markus van der Giet; Olga Jakob; Elke S Schaeffner
Journal:  Br J Clin Pharmacol       Date:  2014-08       Impact factor: 4.335

7.  Residual Associations of Inflammatory Markers with eGFR after Accounting for Measured GFR in a Community-Based Cohort without CKD.

Authors:  Jørgen Schei; Vidar T N Stefansson; Ulla Dorte Mathisen; Bjørn O Eriksen; Marit D Solbu; Trond G Jenssen; Toralf Melsom
Journal:  Clin J Am Soc Nephrol       Date:  2015-12-14       Impact factor: 8.237

8.  Impaired fasting glucose is associated with renal hyperfiltration in the general population.

Authors:  Toralf Melsom; Ulla Dorte Mathisen; Ole C Ingebretsen; Trond G Jenssen; Inger Njølstad; Marit D Solbu; Ingrid Toft; Bjørn O Eriksen
Journal:  Diabetes Care       Date:  2011-05-18       Impact factor: 19.112

9.  Central obesity associates with renal hyperfiltration in the non-diabetic general population: a cross-sectional study.

Authors:  Vidar Tor Nyborg Stefansson; Jørgen Schei; Trond Geir Jenssen; Toralf Melsom; Bjørn Odvar Eriksen
Journal:  BMC Nephrol       Date:  2016-11-10       Impact factor: 2.388

10.  Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 1: How to measure glomerular filtration rate with iohexol?

Authors:  Pierre Delanaye; Natalie Ebert; Toralf Melsom; Flavio Gaspari; Christophe Mariat; Etienne Cavalier; Jonas Björk; Anders Christensson; Ulf Nyman; Esteban Porrini; Giuseppe Remuzzi; Piero Ruggenenti; Elke Schaeffner; Inga Soveri; Gunnar Sterner; Bjørn Odvar Eriksen; Sten-Erik Bäck
Journal:  Clin Kidney J       Date:  2016-08-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.