Literature DB >> 22223168

The reliability of glomerular filtration rate measured from plasma clearance: a multi-centre study of 1,878 healthy potential renal transplant donors.

A Michael Peters1, Bethany Howard, Mark D J Neilly, Nagabhushan Seshadri, Ravin Sobnack, Claire A Hooker, Andrew Irwin, Hayley Snelling, Thomas Gruning, Laura Perry, Neva H Patel, Richard S Lawson, Gregory Shabo, Nigel Williams, Surendra Dave, Mark C Barnfield.   

Abstract

PURPOSE: The objective of the study was to undertake a clinical audit of departmental performance in the measurement of glomerular filtration rate (GFR) using the coefficient of variation (CV) of extracellular fluid volume (ECFV) as the benchmark. ECFV is held within narrow limits in healthy subjects, narrower than GFR, and should therefore have a low CV.
METHODS: Fifteen departments participated in this retrospective study of healthy renal transplant donors. Data were analysed separately for men (n ranged from 28 to 115 per centre; total = 819) and women (n = 28-146; 1,059). All centres used the slope-intercept method with blood sample numbers ranging from two to five. Subjects did not fast prior to GFR measurement. GFR was scaled to body surface area (BSA) and corrected for the single compartment assumption. GFR scaled to ECFV was calculated as the terminal slope rate constant and corrected for the single compartment assumption. ECFV/BSA was calculated as the ratio of GFR/BSA to GFR/ECFV.
RESULTS: The departmental CVs of ECFV/BSA and GFR/BSA ranged from 8.3 to 25.8% and 12.8 to 21.9%, respectively, in men, and from 9.6 to 21.1% and 14.8 to 23.7%, respectively, in women. Both CVs correlated strongly between men and women from the same centre, suggesting department-specific systematic errors. GFR/BSA was higher in men in 14 of 15 centres, whereas GFR/ECFV was higher in women in 14 of 15 centres. Both correlated strongly between men and women, suggesting regional variation in GFR.
CONCLUSION: The CV of ECFV/BSA in normal subjects is a useful indicator of the technical robustness with which GFR is measured and, in this study, indicated a wide variation in departmental performance.

Entities:  

Mesh:

Year:  2012        PMID: 22223168     DOI: 10.1007/s00259-011-2024-5

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  19 in total

1.  Expressing glomerular filtration rate in terms of extracellular fluid volume.

Authors:  A M Peters
Journal:  Nephrol Dial Transplant       Date:  1992       Impact factor: 5.992

Review 2.  Radionuclide clearance techniques.

Authors:  M L Cohen
Journal:  Semin Nucl Med       Date:  1974-01       Impact factor: 4.446

3.  A simple method for the determination of glomerular filtration rate.

Authors:  J Bröchner-Mortensen
Journal:  Scand J Clin Lab Invest       Date:  1972-11       Impact factor: 1.713

4.  Renal inulin clearance versus total plasma clearance of 51Cr-EDTA.

Authors:  J Bröchner-Mortensen; J Giese; N Rossing
Journal:  Scand J Clin Lab Invest       Date:  1969-06       Impact factor: 1.713

5.  Glomerular filtration rate measurement in man by the single injection methods using 51Cr-EDTA.

Authors:  C Chantler; E S Garnett; V Parsons; N Veall
Journal:  Clin Sci       Date:  1969-08       Impact factor: 6.124

Review 6.  The kinetic basis of glomerular filtration rate measurement and new concepts of indexation to body size.

Authors:  A M Peters
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-10-31       Impact factor: 9.236

7.  Using the slope-only technique and estimated glomerular filtration rate for checking the reliability of slope-intercept measurement of glomerular filtration rate.

Authors:  Nicholas J Bird; Christina Peters; A Robert Michell; A Michael Peters
Journal:  Nucl Med Commun       Date:  2008-12       Impact factor: 1.690

8.  Geometric method for measuring body surface area: a height-weight formula validated in infants, children, and adults.

Authors:  G B Haycock; G J Schwartz; D H Wisotsky
Journal:  J Pediatr       Date:  1978-07       Impact factor: 4.406

Review 9.  Control of blood and extracellular volume.

Authors:  A W Cowley; R J Roman
Journal:  Baillieres Clin Endocrinol Metab       Date:  1989-08

10.  Extracellular fluid volume determined by a single injection of inulin in men with untreated essential hypertension.

Authors:  H L Poulsen; H A Jensen; H H Parving
Journal:  Scand J Clin Lab Invest       Date:  1977-12       Impact factor: 1.713

View more
  3 in total

1.  Measuring glomerular filtration rate from plasma clearance of 51Cr-EDTA: quality assurance.

Authors:  Michael Rehling
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-04       Impact factor: 9.236

2.  Comparison of estimated GFR and measured GFR in prospective living kidney donors.

Authors:  Thakshyanee Bhuvanakrishna; Glen M Blake; Rachel Hilton; Lisa Burnapp; Christopher Sibley-Allen; David Goldsmith
Journal:  Int Urol Nephrol       Date:  2014-11-06       Impact factor: 2.370

3.  Glomerular filtration rate in prospective living kidney donors.

Authors:  Glen M Blake; Christopher Sibley-Allen; Rachel Hilton; Lisa Burnapp; Masood R Moghul; David Goldsmith
Journal:  Int Urol Nephrol       Date:  2013-03-06       Impact factor: 2.370

  3 in total