BACKGROUND: Transapical aortic valve implantation (TAVI) for the treatment of severe aortic stenosis requires the insertion of a large catheter through the left ventricular apex. However, the electrocardiographic (ECG) changes associated with the incision and repair of the left ventricular apex and the potential damage to the conduction system caused by implanting a balloon-expandable valve in aortic position are not known. The objective of our study was to determine the incidence, type, and timing of ECG changes associated with TAVI. METHODS: The standard 12-lead ECGs of 33 consecutive patients (mean age 81 +/- 9 years, 13 men) diagnosed with symptomatic severe aortic stenosis (valve area 0.62 +/- 0.16 cm(2)) who underwent TAVI with an Edwards-SAPIEN valve were analyzed at baseline (within 24 hours before the procedure), immediately (within 6 hours) after the procedure, at hospital discharge, and at 1-month follow-up. RESULTS: There were no procedural deaths, and 30-day mortality was 6%. The incidence of complete left ventricular branch block (LBBB) and left anterior hemiblock (LAHB) increased from 9% and 3% at baseline to 27% and 36% after the procedure, respectively (P < .03 for both). A lower (ventricular) position of the valve relative to the hinge point of the anterior mitral leaflet was associated with a higher incidence of new LBBB (35% vs 0%, P = .029); and a greater valve size-aortic annulus ratio, with the occurrence of new LAHB (1.20 +/- 0.07 vs 1.14 +/- 0.06, P = .021). At 1-month follow-up, the rate of LBBB and LAHB decreased to 13% and 10%, respectively (P = not significant compared with baseline). There were no cases of new atrioventricular block, and no patient needed pacemaker implantation. Transient (<48 hours) ST-elevation changes, mostly in the anterior and/or lateral leads, occurred in 6 patients (18%) immediately after the procedure; but only 1 of these patients presented new Q waves at 1-month follow-up. CONCLUSIONS: Transapical aortic valve implantation was associated with a significant but transient (<1 month) increase in LBBB and LAHB, with no patient requiring pacemaker implantation. These changes were partially related to both lower (more ventricular) valve positioning and greater valve oversizing. Transient (<48 hours) ST-segment elevation changes occurred in about one fifth of the patients after the procedure, but only a minority developed new Q waves in the ECG.
BACKGROUND: Transapical aortic valve implantation (TAVI) for the treatment of severe aortic stenosis requires the insertion of a large catheter through the left ventricular apex. However, the electrocardiographic (ECG) changes associated with the incision and repair of the left ventricular apex and the potential damage to the conduction system caused by implanting a balloon-expandable valve in aortic position are not known. The objective of our study was to determine the incidence, type, and timing of ECG changes associated with TAVI. METHODS: The standard 12-lead ECGs of 33 consecutive patients (mean age 81 +/- 9 years, 13 men) diagnosed with symptomatic severe aortic stenosis (valve area 0.62 +/- 0.16 cm(2)) who underwent TAVI with an Edwards-SAPIEN valve were analyzed at baseline (within 24 hours before the procedure), immediately (within 6 hours) after the procedure, at hospital discharge, and at 1-month follow-up. RESULTS: There were no procedural deaths, and 30-day mortality was 6%. The incidence of complete left ventricular branch block (LBBB) and left anterior hemiblock (LAHB) increased from 9% and 3% at baseline to 27% and 36% after the procedure, respectively (P < .03 for both). A lower (ventricular) position of the valve relative to the hinge point of the anterior mitral leaflet was associated with a higher incidence of new LBBB (35% vs 0%, P = .029); and a greater valve size-aortic annulus ratio, with the occurrence of new LAHB (1.20 +/- 0.07 vs 1.14 +/- 0.06, P = .021). At 1-month follow-up, the rate of LBBB and LAHB decreased to 13% and 10%, respectively (P = not significant compared with baseline). There were no cases of new atrioventricular block, and no patient needed pacemaker implantation. Transient (<48 hours) ST-elevation changes, mostly in the anterior and/or lateral leads, occurred in 6 patients (18%) immediately after the procedure; but only 1 of these patients presented new Q waves at 1-month follow-up. CONCLUSIONS: Transapical aortic valve implantation was associated with a significant but transient (<1 month) increase in LBBB and LAHB, with no patient requiring pacemaker implantation. These changes were partially related to both lower (more ventricular) valve positioning and greater valve oversizing. Transient (<48 hours) ST-segment elevation changes occurred in about one fifth of the patients after the procedure, but only a minority developed new Q waves in the ECG.
Authors: Jochen Reinöhl; Constantin von Zur Mühlen; Martin Moser; Stefan Sorg; Christoph Bode; Manfred Zehender Journal: J Thromb Thrombolysis Date: 2013-05 Impact factor: 2.300
Authors: Thomas T Poels; Patrick Houthuizen; Leen A F M Van Garsse; Jos G Maessen; Peter de Jaegere; Frits W Prinzen Journal: J Cardiovasc Transl Res Date: 2014-05-07 Impact factor: 4.132
Authors: Solomon J Sager; Abdulla A Damluji; Joshua A Cohen; Sachil Shah; Brian P O'Neill; Carlos E Alfonso; Claudia A Martinez; Robert J Myerburg; Alan W Heldman; Mauricio G Cohen; Donald B Williams; Roger G Carrillo Journal: J Interv Card Electrophysiol Date: 2016-05-28 Impact factor: 1.900
Authors: Antonio E Dager; Rutger-Jan Nuis; Bernardo Caicedo; Jaime A Fonseca; Camilo Arana; Lidsa Cruz; Luis M Benitez; Carlos A Nader; Eduardo Duenas; Eduardo J de Marchena; William W O'Neill; Peter P de Jaegere Journal: Tex Heart Inst J Date: 2012
Authors: Robert M van der Boon; Rutger-Jan Nuis; Nicolas M Van Mieghem; Luc Jordaens; Josep Rodés-Cabau; Ron T van Domburg; Patrick W Serruys; Robert H Anderson; Peter P T de Jaegere Journal: Nat Rev Cardiol Date: 2012-05-01 Impact factor: 32.419