Literature DB >> 19615659

Orthodontic mini-implant stability in different healing times before loading: a microscopic computerized tomographic and biomechanical analysis.

Lixing Zhao1, Zhenrui Xu, Zhi Yang, Xing Wei, Tian Tang, Zhihe Zhao.   

Abstract

OBJECTIVE: The aim of this study was to evaluate the influence of different healing times before loading on the stability of implanted titanium mini-implant. STUDY
DESIGN: Forty mini-implants were implanted in bilateral maxilla in 10 beagles, loaded with a force of 0.98 N after a delay of 0 day (immediately activated) and 1, 3, 5, and 7 weeks. Microscopic computerized tomography (microCT) and pullout test were used for morphometric and biomechanical analyses, respectively.
RESULTS: All microCT parameters and the F(max) of mini-implants were stimulated with the prolongation of healing time before loading. Between the group of 1 week and 3 weeks, a more obvious rising tendency of both microCT parameters and the F(max) of implants was observed. After 3 weeks, the tendency of increase tapered off.
CONCLUSION: The results indicated that early loading may decrease osseointegration of mini-implants.

Mesh:

Substances:

Year:  2009        PMID: 19615659     DOI: 10.1016/j.tripleo.2009.03.023

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  5 in total

1.  Morphological and structural characteristics of orthodontic mini-implants.

Authors:  Saeed AlSamak; Elias Bitsanis; Margarita Makou; George Eliades
Journal:  J Orofac Orthop       Date:  2012-01-12       Impact factor: 1.938

2.  Effect of placement angle on the stability of loaded titanium microscrews in beagle jaws.

Authors:  Zhenrui Xu; Yeke Wu; Lixing Zhao; Yuqiao Zhou; Xing Wei; Na Tang; Xiaoxia Feng; Tian Tang; Zhihe Zhao
Journal:  Angle Orthod       Date:  2012-12-10       Impact factor: 2.079

3.  Biomechanical Effects of Various Bone-Implant Interfaces on the Stability of Orthodontic Miniscrews: A Finite Element Study.

Authors:  Fabing Tan; Chao Wang; Chongshi Yang; Yuanding Huang; Yubo Fan
Journal:  J Healthc Eng       Date:  2017-06-19       Impact factor: 2.682

4.  Osseointegration of standard and mini dental implants: a histomorphometric comparison.

Authors:  Jagjit S Dhaliwal; Rubens F Albuquerque; Monzur Murshed; Jocelyne S Feine
Journal:  Int J Implant Dent       Date:  2017-05-01

5.  Effect of healing time on bone-implant contact of orthodontic micro-implants: a histologic study.

Authors:  Barat Ali Ramazanzadeh; Kazem Fatemi; Mahboobe Dehghani; Nooshin Mohtasham; Arezoo Jahanbin; Hamed Sadeghian
Journal:  ISRN Dent       Date:  2014-04-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.